Analysis of Waveform-Derived ORA Parameters in Early Forms of Keratoconus and Normal Corneas

被引:36
|
作者
Ventura, Bruna V. [1 ,2 ,3 ]
Machado, Aydano P. [1 ,3 ]
Ambrosio, Renato, Jr. [1 ,4 ,5 ]
Ribeiro, Guilherme [1 ,6 ]
Araujo, Luana N. [1 ,3 ]
Luz, Allan [1 ,4 ,5 ]
Lyra, Joao Marcelo [1 ,6 ]
机构
[1] Brazilian Study Grp Artificial Intelligence & Cor, Rio De Janeiro, Brazil
[2] Altino Ventura Fdn, Recife, PE, Brazil
[3] Univ Fed Alagoas, Maceio, Brazil
[4] Inst Olhos Renato Ambrosio, Rio De Janeiro, Brazil
[5] Univ Fed Sao Paulo, Sao Paulo, Brazil
[6] Univ Ciencias Saude Alagoas, Maceio, Brazil
关键词
OCULAR RESPONSE ANALYZER; INTRAOCULAR-PRESSURE; HYSTERESIS; CHILDREN; EYES;
D O I
10.3928/1081597X-20130819-05
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Depew, NY) performance in differentiating grades I and II keratoconus from normal corneas using 41 parameters individually and to assess the effect of analyzing all parameters together. METHODS: This study compared the mean value of 41 ORA parameters in grades I and II keratoconus with healthy age-matched control eyes. Only eyes with a central corneal thickness between 500 and 600 mu m were included. The area under the receiver operating characteristic curve was calculated for each of the 41 parameters independently and for all of the parameters together. RESULTS: This study included 136 eyes with normal corneas and 68 eyes with grades I and II keratoconus. When analyzed individually, four ORA parameters (p1area, p1area1, p2area, and p2area1) had an area under the curve greater than 0.900 for discriminating between both groups. The p2area was the parameter that achieved the largest area under the curve individually (0.931). The area under the curve increased to 0.978 when analyzing all parameters together. CONCLUSION: Alternative ORA parameters are better for differentiating grades I and II keratoconus from normal corneas than the four parameters originally available for ophthalmologists (corneal hysteresis, Goldmann-correlated intraocular pressure, corneal-compensated intraocular pressure, and corneal resistance factor). Although the ORA did not achieve 100% accuracy, the discrimination between these two groups was optimized by combining all parameters.
引用
收藏
页码:637 / +
页数:11
相关论文
共 23 条
  • [1] Comparison of waveform-derived ORA parameters in clinical keratoconus, subclinical keratoconus and healthy subjects
    Atay, Kubra
    Ozalp, Onur
    Atalay, Eray
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [2] ORA waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes
    Luz, Allan
    Fontes, Bruno Machado
    Lopes, Bernardo
    Ramos, Isaac
    Schor, Paulo
    Ambrosio, Renato, Jr.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (02) : 111 - 117
  • [3] Effect of accelerated corneal crosslinking on ocular response analyzer waveform-derived parameters in progressive keratoconus
    Uzel, Mehmet Murat
    Koc, Mustafa
    Can, Cigdem
    Polat, Sibel
    Yilmazbas, Pelin
    Ileri, Dilek
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2019, 82 (01) : 18 - 24
  • [4] Methodology for Keratoconus Risk Indices Using Ocular Response Analyzer (ORA) Waveform Analysis
    Luce, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Effects of Corneal Cross-Linking on Ocular Response Analyzer Waveform-Derived Variables in Keratoconus and Postrefractive Surgery Ectasia
    Hallahan, Katie M.
    Rocha, Karolinne
    Roy, Abhijit S.
    Randleman, J. Bradley
    Stulting, R. Doyle
    Dupps, William J., Jr.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (06): : 339 - 344
  • [6] Effects of corneal collagen crosslinking on Ocular Response Analyzer Waveform-derived variables in keratoconus and post-LASIK ectasia
    Hallahan, Katie Marie
    Rocha, Karolinne
    Roy, Abhijit Sinha
    Randleman, James Bradley
    Stulting, R. Doyle
    Dupps, William J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Extracting features from normal corneas and keratoconus based on wavelet analysis
    Yu, Jin-Hua
    Ji, Chun-Hong
    Li, Tian-Jie
    Tian, Lei
    Huang, Yi-Fei
    Wang, Yuan-Yuan
    Zheng, Yong-Ping
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (10): : 2919 - 2926
  • [8] Characterization of Corneal Biomechanical Response Parameters in Pellucid Marginal Dystrophy, Keratoconus and Normal Corneas
    Lenk, Janine
    Haustein, Michael
    Spoerl, Eberhard
    Pillunat, Lutz E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [9] Comparative evaluation of dual Scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes
    Reddy, Jagadesh C.
    Rapuarto, Christopher J.
    Cater, Jacqueline R.
    Suri, Kunal
    Nagra, Parveen K.
    Hammersmith, Kristin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 582 - 592
  • [10] Analysis of OPD-Scan and Pentacam Parameters for Early Keratoconus Detection
    Donoso, Rodrigo
    Rodriguez, Alvaro
    Esteffan, Karim
    Lagos, Claudio
    Aranguiz, Diego
    Hernandez, Nicolas
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 226 : 235 - 242