Removal of intra-abdominal intrauterine device by laparoscopy

被引:29
|
作者
Demir, SC [1 ]
Çetin, MT [1 ]
Ürünsak, IF [1 ]
Atay, Y [1 ]
Toksöz, L [1 ]
Kadayifçi, O [1 ]
机构
[1] Cukurova Univ, Fac Med, Dept Obstet & Gynecol, TR-01330 Adana, Turkey
关键词
lost intrauterine device; laparoscopy;
D O I
10.1080/713604287
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective In this study, we aimed to evaluate the cases in which intra-abdominal intrauterine devices (IUDs) were removed by laparoscopy. Methods A retrospective study, from 1994 to 2000 was carried out with eight patients who under-went laparoscopy for the removal of an IUD. The patients admitted to our clinic with 'lost IUD' were examined by pelvic ultrasonography, X-ray and hysteroscopy. IUDs were found to be extrauterine but within the abdominal cavity. The IUDs were removed by operative laparoscopy. Results The mean age of the patients was 31.5 years. The mean duration of usage of IUD was 5.5 years. The IUD was located in the cavity of Douglas in four cases, in the posterior wall of the uterus (perimetrium) in one case and in the conglomerated mass bordered by the intestines in three cases. The types of the IUDs were Cu-T 380A (n = 5), Multiload (n = 1) and Lippes-Loop (n = 2). The mean laparoscopic operation time was 25 min. No major complications (intestinal or vessel injuries) or minor problems occurred. Laparotomy was not necessary in any of the eight cases. All cases were treated as out-patients and discharged on the same day. After counselling, three women requested sterilization, which was performed at the same laparoscopy session by the administration of bilateral Yoon rings, and other family planning methods were chosen by five women. There were no problems when cases were followed at the 10th and 30th postoperative days. Discussion Our results support the idea that, in cases of extrauterine but intra-abdominal IUD, laparoscopic removal of the IUD must be the first choice of therapy.
引用
收藏
页码:20 / 23
页数:4
相关论文
共 50 条
  • [21] USE OF LAPAROSCOPY IN DIAGNOSIS OF ACUTE INTRA-ABDOMINAL BLEEDING
    REMELLI, L
    MALIN, L
    [J]. SURGERY IN ITALY, 1974, 4 (03): : 167 - 173
  • [22] REMOVAL OF AN INTRA-ABDOMINAL TESTIS IN THE DOG
    PEDDIE, JF
    [J]. MODERN VETERINARY PRACTICE, 1981, 62 (03): : 231 - 233
  • [23] MEASUREMENT OF THE INTRA-ABDOMINAL PRESSURE IN THE COURSE OF GYNECOLOGICAL LAPAROSCOPY
    PALMER, R
    BESINS, E
    [J]. CONTRACEPTION FERTILITE SEXUALITE, 1984, 12 (7-8): : 915 - 918
  • [24] Diagnosis and management of intra-abdominal, mislocated intrauterine devices
    Balci, Osman
    Mahmoud, Alaa S.
    Capar, Metin
    Colakoglu, Mehemet C.
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2010, 281 (06) : 1019 - 1022
  • [25] Diagnosis and management of intra-abdominal, mislocated intrauterine devices
    Osman Balci
    Alaa S. Mahmoud
    Metin Capar
    Mehemet C. Colakoglu
    [J]. Archives of Gynecology and Obstetrics, 2010, 281 : 1019 - 1022
  • [26] Surgical management of intra-abdominal mislocated intrauterine devices
    Ozgun, Mahmut T.
    Batukan, Cem
    Serin, Ibrahim S.
    Ozcelik, Bulent
    Basbug, Mustafa
    Dolanbay, Mehmet
    [J]. CONTRACEPTION, 2007, 75 (02) : 96 - 100
  • [27] Surgical removal of intra-abdominal intrauterine devices at one center in a 20-year period
    Ertopcu, Kenan
    Nayki, Cenk
    Ulug, Pasa
    Nayki, Umit
    Gultekin, Emre
    Donmez, Aysegul
    Yildirim, Yusuf
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2015, 128 (01) : 10 - 13
  • [28] Influence of fentanyl on intra-abdominal pressure during laparoscopy in dogs
    Doerfelt, Rene
    Ambrisko, Tamas D.
    Moens, Yves
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2012, 39 (04) : 390 - 397
  • [29] INTRA-ABDOMINAL LIPPES LOOP REMOVED AT LAPAROSCOPY - CASE REPORT
    CIBILS, LA
    MORAGNE, R
    [J]. JOURNAL OF REPRODUCTIVE MEDICINE, 1971, 6 (04) : 194 - &
  • [30] Laparoscopy for the impalpable testes: Experience with 80 intra-abdominal testes
    Hvistendahl, G. M.
    Poulsen, E. U.
    [J]. JOURNAL OF PEDIATRIC UROLOGY, 2009, 5 (05) : 389 - 392