Readout Electronics for the ATLAS LAr Calorimeter at HL-LHC

被引:3
|
作者
Chen, Hucheng [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
Liquid Argon calorimeter; Readout electronics; Radiation hardness;
D O I
10.1016/j.phpro.2012.02.494
中图分类号
O59 [应用物理学];
学科分类号
摘要
The ATLAS Liquid Argon (LAr) calorimeters are high precision, high sensitivity and high granularity detectors designed to provide precision measurements of electrons, photons, jets and missing transverse energy. ATLAS and its LAr calorimeters have been operating and collecting proton-proton collisions at LHC since 2009. The current front-end electronics of the LAr calorimeters need to be upgraded to sustain the higher radiation levels and data rates expected at the upgraded high luminosity LHC machine (HL-LHC), which will have 5 times more luminosity than the LHC in its ultimate configuration. The complexity of the present electronics and the obsolescence of some of components of which it is made, will not allow a partial replacement of the system. A completely new readout architecture scheme is under study and many components are being developed in various R&D programs of the LAr Calorimeter Group. The new front-end readout electronics will send data continuously at each bunch crossing through high speed radiation resistant optical links. The data will be processed real-time with the possibility of implementing trigger algorithms for clusters and electron/photon identification at a higher granularity than that which is currently implemented. The new architecture will eliminate the intrinsic limitation presently existing on Level-1 trigger acceptance. This article is an overview of the R&D activities which covers architectural design aspects of the new electronics as well as some detailed progress on the development of several ASICs needed, and preliminary studies with FPGAs to cover the backend functions including part of the Level-1 trigger requirements. A recently proposed staged upgrade with hybrid Tower Builder Board (TBB) is also described. (C) 2012 Published by Elsevier B.V. Selection and/or peer review under responsibility of the organizing committee for TIPP 11.
引用
收藏
页码:1720 / 1729
页数:10
相关论文
共 50 条
  • [31] Upgrade of the ATLAS Thin Gap Chamber Electronics for HL-LHC runs
    Asada, Haruka
    7TH ANNUAL CONFERENCE ON LARGE HADRON COLLIDER PHYSICS, LHCP2019, 2019,
  • [32] Upgrade for the ATLAS Tile Calorimeter Readout Electronics at the High Luminosity LHC
    Carrio, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 69 - 71
  • [33] The upgraded front-end electronics of the CMS electromagnetic calorimeter for the HL-LHC
    Cometti, S.
    Mazza, G.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2019, 42 (04):
  • [34] Upgraded Trigger Readout Electronics for the ATLAS LAr Calorimeters for Future LHC Running
    Ma, Hong
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [35] The ATLAS tracking system for HL-LHC
    Lapertosa, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (2-3):
  • [36] HL-LHC physics with the ATLAS detector
    Casado, M. P.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2020, 309 : 43 - 48
  • [37] The CMS High Granularity Calorimeter for HL-LHC
    Mastrolorenzo, L.
    PROCEEDINGS OF THE 21ST PARTICLES AND NUCLEI INTERNATIONAL CONFERENCE (PANIC 2017), 2018, 46
  • [38] The upgrade of the CMS electromagnetic calorimeter for HL-LHC
    Cucciati, G.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [39] The CMS High Granularity Calorimeter for HL-LHC
    Chien, C-H.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [40] ATLAS LAr calorimeter performance in LHC run 2 and electronics upgrades for next runs
    McKay, Madalyn
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958