Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics

被引:39
|
作者
Lakey, Andrew [1 ]
Ali, Zulfiqur [1 ]
Scott, Simon M. [1 ]
Chebil, Syrine [2 ]
Korri-Youssoufi, Hafsa [2 ]
Hunor, Santha [3 ]
Ohlander, Anna [4 ]
Kuphal, Mathias [5 ]
Samitier Marti, Josep [5 ]
机构
[1] Teesside Univ, Healthcare Innovat Ctr, Middlesbrough TS1 3BX, Tees Valley, England
[2] Univ Paris Saclay, ECBB, ICMMO, UMR 8182,CNRS,Univ Paris Sud, F-91405 Orsay, France
[3] Budapest Univ Technol & Econ, Dept Elect Technol, Budapest, Hungary
[4] Fraunhofer EMFT, Inst Microsyst & Solid State Technol, Munich, Germany
[5] Barcelona Inst Sci & Technol, IBEC Inst Bioengn Catalonia, Barcelona, Spain
来源
基金
英国工程与自然科学研究理事会;
关键词
Impedimetric sensing; Electropolymerisation; Interdigitated electrodes; Point-of-care diagnostics; Microfluidics; DEEP-VEIN THROMBOSIS; D-DIMER; PULMONARY-EMBOLISM; SELECTIVE IMMUNOSENSOR; BIOSENSOR; GOLD; THROMBOEMBOLISM; NANOPARTICLES; NANOTUBES; ASSAY;
D O I
10.1016/j.bios.2018.12.054
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Deep Vein Thrombosis and pulmonary embolism (DVT/PE) is one of the most common causes of unexpected death for hospital in-patients. D-dimer is used as a biomarker within blood for the diagnosis of DVT/PE. We report a low-cost microfluidic device with a conveniently biofunctionalised interdigitated electrode (IDE) array and a portable impedimetric reader as a point-of-care (POC) device for the detection of D-dimer to aid diagnosis of DVT/PE. The IDE array elements, fabricated on a polyethylenenaphtalate (PEN) substrate, are biofunctionalised in situ after assembly of the microfluidic device by electropolymerisation of a copolymer of polypyrrole to which is immobilised a histidine tag anti-D-Dimer antibody. The most consistent copolymer films were produced using chronopotentiometry with an applied current of 5 mu A for a period of 50 s using a two-electrode system. The quality of the biofunctionalisation was monitored using optical microscopy, chronopotentiometry curves and impedimetric analysis. Measurement of clinical plasma sample with a D-dimer at concentration of 437 ng/mL with 15 biofunctionalised IDE array electrodes gave a ratiometric percentage of sample reading against the blank with an average value of 124 +/- 15 at 95% confidence. We have demonstrated the concept of a low cost disposable microfluidic device with a receptor functionalised on the IDE array for impedimetric detection towards POC diagnostics. Changing the receptor on the IDE array would allow this approach to be used for the direct detection of a wide range of analytes in a low cost manner.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 50 条
  • [21] Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics
    Rasekh, Manoochehr
    Harrison, Sam
    Schobesberger, Silvia
    Ertl, Peter
    Balachandran, Wamadeva
    BIOMEDICAL MICRODEVICES, 2024, 26 (03)
  • [22] Picoliter droplet microfluidic immunosorbent platform for point-of-care diagnostics of tetanus
    Alexander Golberg
    Martin L. Yarmush
    Tania Konry
    Microchimica Acta, 2013, 180 : 855 - 860
  • [23] Hand-Powered Elastomeric Pump for Microfluidic Point-of-Care Diagnostics
    Eluru, Gangadhar
    Adhikari, Jayesh Vasudeva
    Chanda, Priyalaxita
    Gorthi, Sai Siva
    MICROMACHINES, 2020, 11 (01)
  • [24] Opportunities and challenges for the application of microfluidic technologies in point-of-care veterinary diagnostics
    Busin, Valentina
    Wells, Beth
    Kersaudy-Kerhoas, Maiwenn
    Shu, Wenmaio
    Burgess, Stewart T. G.
    MOLECULAR AND CELLULAR PROBES, 2016, 30 (05) : 331 - 341
  • [25] Point-of-care diagnostics for sepsis using clinical biomarkers and microfluidic technology
    Bradley, Zoe
    Bhalla, Nikhil
    BIOSENSORS & BIOELECTRONICS, 2023, 227
  • [26] Product qualification: a barrier to point-of-care microfluidic-based diagnostics?
    Tantra, Ratna
    van Heeren, Henne
    LAB ON A CHIP, 2013, 13 (12) : 2199 - 2201
  • [27] Low-Cost, Rapid Prototyping of a Microfluidic Biosensor Cartridge for On-Farm Diagnostics
    Agnew, Matthew
    Creedon, A. Niamh
    O'Connell, Ivan
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,
  • [28] Impedimetric Point-of-Care Cardiac Marker System
    Hamad, Eyad M.
    McAdams, Eric T.
    McLaughlin, James A.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 201 - 204
  • [29] A microfluidic platform with digital readout and ultra-low detection limit for quantitative point-of-care diagnostics
    Li, Ying
    Xuan, Jie
    Song, Yujun
    Wang, Ping
    Qin, Lidong
    LAB ON A CHIP, 2015, 15 (16) : 3300 - 3306
  • [30] Low-cost sheath-less microfluidic impedance cytometry for point-of-care applications
    Hosseini, Seied Ali
    Bahrami, Sanaz
    Zolghadr, Leila
    Gheibi, Nematollah
    MICROFLUIDICS AND NANOFLUIDICS, 2024, 28 (01)