Electrochemical properties and electrocatalytic activity of FAD immobilized onto cobalt oxide nanoparticles: Application to nitrite detection

被引:69
|
作者
Salimi, Abdollah [1 ,2 ]
Hallaj, Rahman [1 ]
Mamkhezri, Hussein [1 ]
Hosaini, Sayed Mohamad Taher [3 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj, Iran
[3] Univ Kurdistan, Dept Agron, Fac Agr, Sanandaj, Iran
关键词
FAD; cobalt oxide; nanoparticles; glassy carbon electrode; nitrite; sensor;
D O I
10.1016/j.jelechem.2008.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclic voltammetry has been used for modification of glassy carbon (CC) electrode with cobalt oxide (CoOx) nanoparticles and flavin adenine dinucleoticle (FAD) film. Electrodeposited cobalt oxide may be a promising material for FAD immobilization owing to its high biocompatibility and large surface. The adsorbed FAD film is stable and electrochemically active in aqueous solution. The FAD films assembled on cobalt oxide exhibited a pair of well defined, stable and nearly reveisible CV peaks at wide pH range. The formal potential of adsorbed FAD onto cobalt oxide nanoparticles film, E-0,E- vs. Ag/AgCl reference electrode is -0.44 V in pH 7 buffer solution was similar to dissolved FAD and changed linearly with a slope of 46 mV/pH in the pH range 4-12. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of FAD immobilized on CoOx film glassy carbon electrode are 1.47 x 10(-9) mol cm(-2) and 0.85 +/- 0.1 s(-1), indicating the high loading ability of the CoOx nanoparticles and great facilitation of the electron transfer between FAD and CoOx nanoparticles. Cobalt oxide/FAD composite modified GC electrode shows excellent catalytic activity for nitrite reduction at reduced overpotential. Furthermore, FAD/CoOx rotating disk electrode modified CC electrode shows good analytical performance for amperometric determination nitrite. Under optimized condition of the amperometry method the concentration calibration range, detection limit and sensitivity are 1-30 mu M, 0.20 mu M and 10.5 nA/mu M, respectively. Finally the kinetics of the catalytic reaction between nitrite anion and reduced FAD was characterized, using cyclic voltammetry and a value of 2.08 (+/- 0.3) x 10(3) M-1 s(-1) was obtained for the rate constant. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [41] Nickel/Nickel(II) Oxide Nanoparticles Anchored onto Cobalt(IV) Diselenide Nanobelts for the Electrochemical Production of Hydrogen
    Xu, Yun-Fei
    Gao, Min-Rui
    Zheng, Ya-Rong
    Jiang, Jun
    Yu, Shu-Hong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (33) : 8546 - 8550
  • [42] Manganese Oxide Nanoparticles/Reduced Graphene Oxide as Novel Electrochemical Platform for Immobilization of FAD and its Application as Highly Sensitive Persulfate Sensor
    Majd, Samira Mansouri
    Salimi, Abdollah
    Astinchap, Bandar
    ELECTROANALYSIS, 2016, 28 (03) : 493 - 502
  • [43] Pt nanoparticles ion-implanted onto indium tin oxide electrodes and their electrocatalytic activity towards methanol
    Liang, Fenfen
    Tian, Huifeng
    Jia, Mingzhe
    Hu, Jingbo
    JOURNAL OF POWER SOURCES, 2013, 225 : 9 - 12
  • [44] Cobalt oxide nanoparticles anchored to multiwalled carbon nanotubes: Synthesis and application for enhanced electrocatalytic reaction and highly sensitive nonenzymatic detection of hydrogen peroxide
    Heli, H.
    Pishahang, J.
    ELECTROCHIMICA ACTA, 2014, 123 : 518 - 526
  • [45] Enhanced His@AuNCs oxidase-like activity by reduced graphene oxide and its application for colorimetric and electrochemical detection of nitrite
    Lu Liu
    Jie Du
    Wen-e Liu
    Yongliang Guo
    Guofan Wu
    Weinan Qi
    Xiaoquan Lu
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2189 - 2200
  • [46] Enhanced His@AuNCs oxidase-like activity by reduced graphene oxide and its application for colorimetric and electrochemical detection of nitrite
    Liu, Lu
    Du, Jie
    Liu, Wen-e
    Guo, Yongliang
    Wu, Guofan
    Qi, Weinan
    Lu, Xiaoquan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (10) : 2189 - 2200
  • [47] Amperometric detection of acetaminophen by an electrochemical sensor based on cobalt oxide nanoparticles in a flow injection system
    Razmi, Habib
    Habibi, Esmaeil
    ELECTROCHIMICA ACTA, 2010, 55 (28) : 8731 - 8737
  • [48] Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
    Huang, Shan
    Lu, Ming
    Wang, Lei
    RSC ADVANCES, 2021, 11 (01) : 501 - 509
  • [49] Immobilization of hemoglobin on cobalt nanoparticles-modified indium tin oxide electrode: Direct electrochemistry and electrocatalytic activity
    Shuo-qi Li
    Jing-bo Hu
    Chemical Research in Chinese Universities, 2013, 29 : 563 - 567
  • [50] Immobilization of Hemoglobin on Cobalt Nanoparticles-modified Indium Tin Oxide Electrode: Direct Electrochemistry and Electrocatalytic Activity
    Li Shuo-qi
    Hu Jing-bo
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (03) : 563 - 567