A new concept of hip joint stem and its fabrication using metastable TiNbSn alloy

被引:20
|
作者
Jung, Taek-Kyun [1 ]
Lee, Hyo-Soo [1 ]
Semboshi, Satoshi [2 ]
Masahashi, Naoya [2 ]
Abumiya, Tadasu [2 ]
Hanada, Shuji [2 ]
机构
[1] Korea Inst Ind Technol, Inchon 406840, South Korea
[2] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 9808577, Japan
关键词
TiNbSn alloys; Cold groove rolling; Cold swaging; Local heating; Young's modulus; Tensile strength; LOW YOUNGS MODULUS; MECHANICAL-PROPERTIES; TITANIUM-ALLOYS;
D O I
10.1016/j.jallcom.2011.12.077
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cold worked (Ti-35%Nb)-4%Sn alloy rods were locally heated to investigate the gradation of mechanical properties and develop an advanced Ti alloy stem for application as an artificial hip joint. Cold groove rolling was found to decrease Young's modulus, but subsequent cold swaging increased Young's modulus and tensile strength. Heating one edge of the cold worked rods resulted in the tensile strength and Young's modulus increasing significantly in the heated zone; the increase varied depending on the distance from the heated zone. The increase in tensile strength was attributed to the omega precipitation and the additional microstructure refinement by reverse transformation of alpha '' to beta. We could successfully fabricate an advanced hip joint stem with a tensile strength of 1.3 GPa in the proximal portion and Young's modulus of 43 GPa in the distal portion. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:S582 / S585
页数:4
相关论文
共 50 条
  • [31] A new drive system using a shape memory alloy (SMA) heat engine and its applications
    Kanada, T.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (05): : 1061 - 1063
  • [32] Fabrication and characterization of a new high-strength alloy via WAAM using GMAW plus cold wire feeding
    Ayan, Yusuf
    MATERIALS CHEMISTRY AND PHYSICS, 2024, 328
  • [33] Bony abnormalities of the hip joint: a new comprehensive, reliable and radiation-free measurement method using magnetic resonance imaging
    Harris-Hayes, Marcie
    Commean, Paul K.
    Patterson, Jacqueline D.
    Clohisy, John C.
    Hillen, Travis J.
    JOURNAL OF HIP PRESERVATION SURGERY, 2014, 1 (02): : 62 - 70
  • [34] The Joint Clinic: Managing Excess Demand for Hip and Knee Osteoarthritis Referrals Using a New Physiotherapy-Led Outpatient Service
    Gwynne-Jones, David P.
    Hutton, Liam R.
    Stout, Kirsten M.
    Abbott, J. Haxby
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 983 - 987
  • [35] Calculation of metastable free-energy diagrams and glass formation in the Mg-Cu-Y alloy and its boundary binaries using the Miedema model
    de Tendler, R. Hojvat
    Soriano, M. R.
    Pepe, M. E.
    Kovacs, J. A.
    Vicente, E. E.
    Alonso, J. A.
    INTERMETALLICS, 2006, 14 (03) : 297 - 307
  • [36] GENERAL-ANALYSIS OF MAGNETIC REFRIGERATION AND ITS OPTIMIZATION USING A NEW CONCEPT - MAXIMIZATION OF REFRIGERANT CAPACITY
    WOOD, ME
    POTTER, WH
    CRYOGENICS, 1985, 25 (12) : 667 - 683
  • [37] New Concept of Thin-Film Composite Nanofiltration Membrane Fabrication Using a Mist-Based Interfacial Polymerization Technique
    Seah, Mei Qun
    Khoo, Ying Siew
    Lau, Woei Jye
    Goh, Pei Sean
    Ismail, Ahmad Fauzi
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2021, 60 (25) : 9167 - 9178
  • [39] A NEW PATTERNING PROCESS CONCEPT FOR LARGE-AREA TRANSISTOR-CIRCUIT FABRICATION WITHOUT USING AN OPTICAL MASK ALIGNER
    MIKAMI, Y
    NAGAE, Y
    MORI, Y
    KUWABARA, K
    SAITO, T
    HAYAMA, H
    ASADA, H
    AKIMOTO, Y
    KOBAYASHI, M
    OKAZAKI, S
    ASAKA, K
    MATSUI, H
    NAKAMURA, K
    KANEKO, E
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (03) : 306 - 314
  • [40] Using a scale-bridging technique to determine the effect of elastic properties on stress distribution around the femoral stem of an artificial hip joint with a simplified geometry
    C. U. Jeong
    S. -C. Lee
    H. N. Rhee
    K. S. Park
    S. -H. Choi