3D Stent Recovery from One X-Ray Projection

被引:0
|
作者
Demirci, Stefanie [1 ]
Bigdelou, Ali [1 ]
Wang, Lejing [1 ]
Wachinger, Christian [1 ]
Baust, Maximilian [1 ]
Tibrewal, Radhika [1 ]
Ghotbi, Reza [2 ]
Eckstein, Hans-Henning [3 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Comp Aided Med Procedures, D-8000 Munich, Germany
[2] Klinikum Munchen Pasing, Vasc Surg, Munich, Germany
[3] Klinikum Rechts Der Isar, Dept Vasc Surg, Munich, Germany
关键词
REGISTRATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the current clinical workflow of endovascular abdominal aortic repairs (EVAR) a stent graft is inserted into the aneurysmatic aorta under 2D angiographic imaging. Due to the missing depth information in the X-ray visualization, it is highly difficult in particular for junior physicians to place the stent graft in the preoperatively defined position within the aorta. Therefore, advanced 3D visualization of stent grafts is highly required. In this paper, we present a novel algorithm to automatically match a 3D model of the stent graft to an intraoperative 2D image showing the device. By automatic preprocessing and a global-to-local registration approach, we are able to abandon user interaction and still meet the desired robustness. The complexity of our registration scheme is reduced by a semi-simultaneous optimization strategy incorporating constraints that correspond to the geometric model of the stent graft. Via experiments on synthetic, phantom, and real interventional data, we are able to show that the presented method matches the stent graft model to the 2D image data with good accuracy.
引用
收藏
页码:178 / +
页数:2
相关论文
共 50 条
  • [1] 3D localization from 2D X-ray projection
    Dagmar Bertsche
    Volker Rasche
    Wolfgang Rottbauer
    Ina Vernikouskaya
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1553 - 1558
  • [2] 3D localization from 2D X-ray projection
    Bertsche, Dagmar
    Rasche, Volker
    Rottbauer, Wolfgang
    Vernikouskaya, Ina
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (09) : 1553 - 1558
  • [3] The X-Ray Transform Projection of 3D Mother Wavelet Function
    Yang, Xiangyu
    Guo, Jiqiang
    Lu, Li
    Zeng, Li
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [4] HOOREX: Higher Order Optimizers for 3D Recovery from X-Ray Images
    Shetty, Karthik
    Birkhold, Annette
    Egger, Bernhard
    Jaganathan, Srikrishna
    Strobel, Norbert
    Kowarschik, Markus
    Maier, Andreas
    MACHINE LEARNING FOR MULTIMODAL HEALTHCARE DATA, ML4MHD 2023, 2024, 14315 : 115 - 124
  • [6] 3D x-ray angiography
    Hoffmann, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1278 - 1278
  • [7] 3D localization of electrophysiology catheters from a single x-ray cone-beam projection
    Robert, Normand
    Polack, George G.
    Sethi, Benu
    Rowlands, John A.
    Crystal, Eugene
    MEDICAL PHYSICS, 2015, 42 (10) : 6112 - 6124
  • [8] Limited projection 3D X-ray tomography using the Maximum Entropy Method
    Vengrinovich, VL
    Denkevich, YB
    Tillack, GR
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 403 - 410
  • [9] 3D x-ray angiography: Study of factors affecting projection data consistency
    Hsiung, HH
    Sen, A
    Schueler, BA
    Hu, XP
    Latchaw, RE
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 226 - 237
  • [10] 3D modeling of the vessels from X-ray angiography
    Lee, Na-Young
    Kim, Gye-Young
    Choi, Hyung-Il
    DIGITAL HUMAN MODELING, 2007, 4561 : 646 - 654