The all-inside all-suture technique demonstrated better biomechanical behaviors in meniscus radial tear repair

被引:10
|
作者
Doig, Timothy [1 ]
Fagan, Paul [2 ]
Frush, Todd [1 ,2 ]
Lovse, Lisa [1 ]
Chen, Chaoyang [2 ]
Lemos, Stephen [1 ,2 ]
机构
[1] Detroit Med Ctr Sports Med, DMC Sports Med Orthopaed Surg Fellowship Program, 3990 John R St,POB 137, Detroit, MI 48201 USA
[2] Detroit Med Ctr, Dept Orthopaed Surg & Sports Med, 3990 John R St,POB 137, Detroit, MI 48201 USA
关键词
Meniscus repair; Biomechanics; Radial tear; Knee scorpion; Meniscal cinch; ARTHROSCOPIC REPAIR; HORIZONTAL SUTURE; OUT REPAIR; KNEE; CONSTRUCTS; EXTRUSION;
D O I
10.1007/s00167-020-06078-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to evaluate the effectiveness of three constructs and techniques for repair of radial tears of the meniscus. Methods Thirty fresh frozen porcine menisci were divided equally into three groups consisting of (1) inside-out repair group, (2) a commonly used all-inside suture with anchor hybrid repair construct (AISAH) (Meniscal Cinch (TM)), and (3) an all-inside all-suture repair construct (AIAS) (Knee Scorpion (TM)). Radial tears were created and repaired and then the menisci were secured to the materials testing machine. Both cyclic loading and load-to-failure testing were performed. The displacement, stiffness, response to cyclic loading, and mode of failure were recorded and analyzed statistically. Results The displacement after cyclic loading (DACL) of the Cinch repair construct group was significantly higher than that of the inside-out repair construct group (p = 0.000) and AIAS repair construct (p = 0.000). There was not a statistical difference of DACL between inside-out and AIAS groups (n.s.). The inside-out construct failed at a significantly higher load than the AISAH repair construct (p = 0.000) and AIAS construct (p = 0.006). The AIAS construct failed at a significantly higher load than the AISAH repair construct (p = 0.009). The AIAS had a higher stiffness than AISAH (p = 0.047). The AIAS had a higher load at 3 mm protrusion than AISAH (p = 0.034). Conclusion The AIAS repair construct had better biomechanical behaviors than AISAH construct and inside-out repair technique. Inside-out sutures and AIAS repair construct had similar biomechanical responses to cyclic loading. The AIAS can be used for meniscus tear surgical repair with less damage to peri-meniscus tissues.
引用
收藏
页码:3606 / 3612
页数:7
相关论文
共 50 条
  • [1] The all-inside all-suture technique demonstrated better biomechanical behaviors in meniscus radial tear repair
    Timothy Doig
    Paul Fagan
    Todd Frush
    Lisa Lovse
    Chaoyang Chen
    Stephen Lemos
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 3606 - 3612
  • [2] Biomechanical Comparison of All-Suture, All-Inside Meniscus Repair Devices in a Human Cadaveric Meniscus Model
    Massey, Patrick A.
    Scalisi, Wayne
    Montgomery, Carver
    Daily, Drayton
    Robinson, James
    Solitro, Giovanni F.
    CARTILAGE, 2024,
  • [3] Arthroscopic Meniscus Repair Using an All-Inside, All-Suture, Knotless Device
    Avila, Amanda
    Rao, Naina
    Buzin, Scott
    Shankar, Dhruv S.
    Davidson, Phil
    Strauss, Eric J.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (05): : E615 - E619
  • [4] All-Inside Repair for Radial Tear at the Posterior Horn of the Lateral Meniscus: A Figure-8 Suture Technique
    Sanada, Takaki
    Iwaso, Hiroshi
    Honda, Eisaburo
    Yoshitomi, Hiroki
    Inagawa, Miyu
    ARTHROSCOPY TECHNIQUES, 2021, 10 (08): : E1973 - E1977
  • [5] New meniscus repair by an all-inside knot suture technique
    Fukushima, K
    Okano, T
    Negishi, S
    Horaguchi, T
    Sato, K
    Saito, A
    Ryu, J
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (06): : 768 - U112
  • [6] All-Inside Repair for a Root Tear of the Medial Meniscus Using a Suture Anchor
    Jung, Yu-Hun
    Choi, Nam-Hong
    Oh, Jong-Seok
    Victoroff, Brian N.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (06): : 1406 - 1411
  • [7] All-Inside Arthroscopic Tie-Grip Suture Repair for Radial Tear in the Midbody of Lateral Meniscus Using an All-Inside Device and Slotted Cannula
    Iguchi, Masaki
    Takahashi, Tsuneari
    Handa, Mikiko
    Takeshita, Katsushi
    ARTHROSCOPY TECHNIQUES, 2024, 13 (12):
  • [8] All-Inside Suture Repair for Isolated Radial Tears at the Midbody of the Lateral Meniscus
    Uchida, Ryohei
    Horibe, Shuji
    Shiozaki, Yoshiki
    Shino, Konsei
    ARTHROSCOPY TECHNIQUES, 2019, 8 (12): : E1451 - E1456
  • [9] A Biomechanical Comparison of All-Inside Meniscus Repair Techniques
    Chang, Jen-Huei
    Shen, Hsain-Chung
    Huang, Guo-Shu
    Pan, Ru-Yu
    Wu, Chi-Fang
    Lee, Chian-Her
    Chen, Qian
    JOURNAL OF SURGICAL RESEARCH, 2009, 155 (01) : 82 - 88
  • [10] A new, all-inside technique for meniscus repair
    Miura, H
    Kawamura, H
    Arima, J
    Mawatari, T
    Nagamine, R
    Urabe, K
    Iwamoto, Y
    ARTHROSCOPY, 1999, 15 (04): : 453 - 455