A Biomechanical Comparison of All-Inside Meniscus Repair Techniques

被引:20
|
作者
Chang, Jen-Huei [2 ]
Shen, Hsain-Chung [2 ]
Huang, Guo-Shu [3 ]
Pan, Ru-Yu [2 ]
Wu, Chi-Fang [4 ]
Lee, Chian-Her [1 ,2 ]
Chen, Qian [5 ]
机构
[1] Taipei Med Univ Hosp, Taipei 110, Taiwan
[2] Tri Serv Gen Hosp, Dept Orthopaed, Taipei, Taiwan
[3] Tri Serv Gen Hosp, Dept Radiol, Taipei, Taiwan
[4] Natl Def Med Ctr, Inst Publ Hlth, Taipei, Taiwan
[5] Brown Univ, Rhode Isl Hosp, Dept Orthopaed, Warren Albert Med Sch, Providence, RI 02903 USA
关键词
meniscus sutures; anchors; cyclic loading; porcine; SUTURING TECHNIQUES; MEDIAL MENISCUS; KNEE-JOINT; STRENGTH; FAILURE; RESECTION; DEVICES; LOAD;
D O I
10.1016/j.jss.2008.10.002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The aim of this study was to assess the biomechanical characteristics of six all-inside meniscal single suture repair techniques using a porcine model. Materials and Methods. Peripheral longitudinal tears were created in freshly isolated porcine menisci. Tears were repaired using the single vertical technique with six different repair complexes including those involving sutures (#2 FiberWire, #2 Ethibone, flexible anchors (Fast-Fix, RapidLoc), and rigid anchors (Meniscal-Dart, BioStinger). Displacement, ultimate failure strength, stiffness, and site of failure were measured using a Materials Testing System machine. An initial 2 N preload was applied, followed by loading between 5 and 20 N for 300 cycles. Failure strength was determined lastly by increasing tension at a rate of 5 mm/min until failure. Results. Failure strength was highest in the #2 FiberWire group (175.6 N). This was significantly higher than in all other groups (P < 0.05). The second highest failure load was evident in the #2 Ethibone group (113.8 N). This was significantly higher than in all other groups bar the #2 FiberWire group (P < 0.05). Stiffness was also significantly higher in the #2 FiberWire group compared with all other groups (8.5 N/mm, P < 0.05). There were no between-group differences in displacement. When grouped by repair technique, failure load was significantly higher, and displacement was significantly lower, in suture compared with both flexible and rigid anchor repaired menisci (P < 0.01 for all comparisons). Although stiffness was also higher in the suture group, there were no significant between group differences detected. Conclusions. Suture techniques exhibited biomechanical superiority over biodegradable flexible and rigid anchor devices for meniscus repair. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [1] A Biomechanical Comparison of All-Inside Versus Transtibial Meniscus Root Repair Techniques
    Pasic, Nicholas
    Storaci, Hunter
    Guzman, Roberto
    Debaun, Malcolm
    Maruyama, Masahiro
    Hall, Kimberly
    Salazar, Brett P.
    Dragoo, Jason L.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (09): : 2366 - 2373
  • [2] All-Inside Meniscus Repair
    Golz, A. G.
    Mandelbaum, B.
    Pace, J. L.
    [J]. CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2022, 15 (04) : 252 - 258
  • [3] All-Inside Meniscus Repair
    A. G. Golz
    B. Mandelbaum
    J. L. Pace
    [J]. Current Reviews in Musculoskeletal Medicine, 2022, 15 : 252 - 258
  • [4] Biomechanical Comparison of All-Suture, All-Inside Meniscus Repair Devices in a Human Cadaveric Meniscus Model
    Massey, Patrick A.
    Scalisi, Wayne
    Montgomery, Carver
    Daily, Drayton
    Robinson, James
    Solitro, Giovanni F.
    [J]. CARTILAGE, 2024,
  • [5] Arthroscopic all-inside meniscus repair
    Reigel, CA
    Mulhollan, JS
    Morgan, CD
    [J]. CLINICS IN SPORTS MEDICINE, 1996, 15 (03) : 483 - &
  • [6] Biomechanical evaluation of arthroscopic all-inside meniscus repairs
    Taner Gunes
    Bora Bostan
    Mehmet Erdem
    Murat Asci
    Cengiz Sen
    Mehmet Halidun Kelestemur
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 1347 - 1353
  • [7] All-inside meniscus repair - A systematic review
    Lozano, Jesus
    Ma, C. Benjamin
    Cannon, W. Dilworth
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (455) : 134 - 141
  • [8] Biomechanical evaluation of arthroscopic all-inside meniscus repairs
    Gunes, Taner
    Bostan, Bora
    Erdem, Mehmet
    Asci, Murat
    Sen, Cengiz
    Kelestemur, Mehmet Halidun
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (11) : 1347 - 1353
  • [9] A new, all-inside technique for meniscus repair
    Miura, H
    Kawamura, H
    Arima, J
    Mawatari, T
    Nagamine, R
    Urabe, K
    Iwamoto, Y
    [J]. ARTHROSCOPY, 1999, 15 (04): : 453 - 455
  • [10] Meniscus Repair in the Posterior Third: The All-Inside Option
    Nixon, Ryan
    Stein, Spencer M.
    Sgaglione, Nicholas A.
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (04) : 246 - 250