Comparison of Blood Oxygenation Level-Dependent fMRI and Provocative DSC Perfusion MR Imaging for Monitoring Cerebrovascular Reserve in Intracranial Chronic Cerebrovascular Disease

被引:3
|
作者
Thulborn, K. R. [1 ]
Atkinson, I. C. [1 ]
Alexander, A. [1 ]
Singal, M. [1 ]
Amin-Hanjani, S. [2 ]
Du, X. [2 ]
Alaraj, A. [2 ]
Charbel, F. T. [2 ]
机构
[1] Univ Illinois, Med Ctr, Ctr Magnet Resonance Res, Chicago, IL USA
[2] Univ Illinois, Med Ctr, Dept Neurol Surg, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; FLOW; OCCLUSION; STROKE;
D O I
10.3174/ajnr.A5515
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Loss of hemodynamic reserve in intracranial cerebrovascular disease reduces blood oxygenation level-dependent activation by fMRI and increases asymmetry in MTT measured by provocative DSC perfusion MR imaging before and after vasodilation with intravenous acetazolamide. The concordance for detecting hemodynamic reserve integrity has been compared. MATERIALS AND METHODS: Patients (n = 40) with intracranial cerebrovascular disease and technically adequate DSA, fMRI and provocative DSC perfusion studies were retrospectively grouped into single vessels proximal to and distal from the circle of Willis, multiple vessels, and Moyamoya disease. The vascular territories were classified as having compromised hemodynamic reserve if the expected fMRI blood oxygenation level-dependent activation was absent or if MTT showed increased asymmetry following vasodilation. Concordance was examined in compromised and uncompromised vascular territories of each group with the Fischer exact test and proportions of agreement. RESULTS: Extensive leptomeningeal collateral circulation was present in all cases. Decreased concordance between the methods was found in vascular territories with stenosis distal to but not proximal to the circle of Willis. Multivessel and Moyamoya diseases also showed low concordance. A model of multiple temporally displaced arterial inputs from leptomeningeal collateral flow demonstrated that the resultant lengthening MTT mimicked compromised hemodynamic reserve despite being sufficient to support blood oxygenation level-dependent contrast. CONCLUSIONS: Decreased concordance between the 2 methods for assessment of hemodynamic reserve for vascular disease distal to the circle of Willis is posited to be due to well-developed leptomeningeal collateral circulation providing multiple temporally displaced arterial input functions that bias the perfusion analysis toward hemodynamic reserve compromise while blood oxygenation level-dependent activation remains detectable.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [31] Blood Oxygenation Level-Dependent Cerebrovascular Reactivity-Derived Steal Phenomenon May Indicate Tissue Reperfusion Failure After Successful Endovascular Thrombectomy
    Bellomo, Jacopo
    Sebok, Martina
    Stumpo, Vittorio
    van Niftrik, Christiaan H. B.
    Meisterhans, Darja
    Piccirelli, Marco
    Michels, Lars
    Reolon, Beno
    Esposito, Giuseppe
    Schubert, Tilman
    Kulcsar, Zsolt
    Luft, Andreas R.
    Wegener, Susanne
    Regli, Luca
    Fierstra, Jorn
    TRANSLATIONAL STROKE RESEARCH, 2023, 16 (2) : 207 - 216
  • [32] Emotion processing in Parkinson's disease: a blood oxygenation level-dependent functional magnetic resonance imaging study
    Benzagmout, Mohammed
    Boujraf, Said
    Alami, Badreeddine
    Amadou, Hassane Ali
    El Hamdaoui, Halima
    Bennani, Amine
    Jaafari, Mounir
    Rammouz, Ismail
    Maaroufi, Mustapha
    Magoul, Rabia
    Boussaoud, Driss
    NEURAL REGENERATION RESEARCH, 2019, 14 (04) : 666 - 672
  • [33] Fetoplacental Oxygenation in an Intrauterine Growth Restriction Rat Model by Using Blood Oxygen Level-Dependent MR Imaging at 4.7 T
    Chalouhi, Gihad E.
    Alison, Marianne
    Deloison, Benjamin
    Thiam, Rokhaya
    Autret, Gwennhael
    Balvay, Daniel
    Cuenod, Charles A.
    Clement, Olivier
    Salomon, Laurent J.
    Siauve, Nathalie
    RADIOLOGY, 2013, 269 (01) : 122 - 129
  • [34] Mapping cerebrovascular reactivity using blood oxygen level-dependent MRI in patients with arterial steno-occlusive disease - Comparison with arterial spin labeling MRI
    Mandell, Daniel M.
    Han, Jay S.
    Poublanc, Julien
    Crawley, Adrian P.
    Stainsby, Jeff A.
    Fisher, Joseph A.
    Mikulis, David J.
    STROKE, 2008, 39 (07) : 2021 - 2028
  • [35] Pathological Factors Affecting the R2*Values of the Kidney in Blood Oxygenation Level-dependent MR Imaging: A Retrospective Study
    Nishino, Tomohiko
    Takahashi, Kazuhiro
    Ono, Sayaka
    Mimaki, Masakazu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (02) : 153 - 160
  • [36] Blood Oxygen Level-Dependent Magnetic Resonance Imaging in Comparison to Fractional Flow Reserve for the Detection of Coronary Artery Stenosis
    Voehringer, Matthias
    Flewitt, Jacqueline A.
    Green, Jordin D.
    Tyberg, John V.
    Friedrich, Matthias G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A284 - A284
  • [37] FRACTIONAL FLOW RESERVE CORRELATES WITH BLOOD OXYGEN LEVEL-DEPENDENT (BOLD) MAGNETIC RESONANCE IMAGING IN CORONARY ARTERY DISEASE
    Bernhardt, Peter
    Rottbauer, Wolfgang
    Woehrle, Jochen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1068 - E1068
  • [38] Renal oxygenation changes during acute unilateral ureteral obstruction: Assessment with blood oxygen level-dependent MR imaging - Initial experience
    Thoeny, Harriet C.
    Kessler, Thomas M.
    Simon-Zoula, Sonia
    De Keyzer, Frederik
    Mohaupt, Markus
    Studer, Urs E.
    Vermathen, Peter
    RADIOLOGY, 2008, 247 (03) : 754 - 761
  • [39] Dynamic Blood Oxygen Level-dependent MR Imaging of Muscle: Comparison of Postocclusive Reactive Hyperemia in Young Smokers and Nonsmokers
    Nismii, Tatsuya
    Kono, Atsushi K.
    Nishio, Mizuho
    Kyotani, Katsusuke
    Nishiyama, Kouya
    Sugimura, Kazuro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (04) : 275 - 283
  • [40] Myocardial Perfusion Reserve Assessed by T2-Prepared Steady-State Free Precession Blood Oxygen Level-Dependent Magnetic Resonance Imaging in Comparison to Fractional Flow Reserve
    Walcher, Thomas
    Manzke, Robert
    Hombach, Vinzenz
    Rottbauer, Wolfgang
    Woehrle, Jochen
    Bernhardt, Peter
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (05) : 580 - 586