Instrumental validity and intra/inter-rater reliability of a novel low-cost digital pressure algometer

被引:13
|
作者
Jerez-Mayorga, Daniel [1 ]
dos Anjos, Carolina Fernanda [2 ]
Macedo, Maria de Cassia [2 ]
Fernandes, Ilha Goncalves [2 ]
Aedo-Munoz, Esteban [3 ]
Intelangelo, Leonardo [4 ]
Barbosa, Alexandre Carvalho [2 ]
机构
[1] Univ Andres Bello, Fac Ciencias Rehabil, Santiago, Chile
[2] Univ Fed Juiz de Fora, Dept Phys Therapy, Governador Valadares, MG, Brazil
[3] Univ Fed Juiz de Fora, Dept Phys Educ, Governador Valadares, MG, Brazil
[4] Univ Gran Rosario, Dept Phys Therapy, Rosario, Santa Fe, Argentina
来源
PEERJ | 2020年 / 8卷
关键词
Pain assessment; Validity; Reliability; Pressure algometry; Pressure pain threshold; Inexpensive; PAIN THRESHOLD; SEX-DIFFERENCES; INDIVIDUALS; SENSITIVITY; VALIDATION; EXERCISE;
D O I
10.7717/peerj.10162
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Pain assessment is a key measure that accompanies treatments in a wide range of clinical settings. A low-cost valid and reliable pressure algometer would allow objective assessment of pressure pain to assist a variety of health professionals. However, the pressure algometer is often expensive, which limits its daily use in both clinical and research settings. Objectives: This study aimed to assess the instrumental validity, and the intraand inter-rater reliability of an inexpensive digital adapted pressure algometer. Methods: A single rater applied 60 random compressions on a force platform. The pressure pain thresholds of 20 volunteers were collected twice (3 days apart ) by two raters. The main outcome measurements were as follows: the maximal peak force (in kPa) and the pressure pain threshold (adapted pressure algometer vs. force platform). Cronbach's a test was used to assess internal consistency. The standard error of measurement provided estimates of measurement error, and the measurement bias was estimated with the Bland-Altman method, with lower and upper limits of agreement. Results: No differences were observed when comparing the compression results (P = 0.51). The validity and internal intra-rater consistencies ranged from 0.84 to 0.99, and the standard error of measurement from 0.005 to 0.04 kPa. Very strong (r = 0.73-0.74) to near-perfect (r = 0.99) correlations were found, with a low risk of bias for all measurements. The results demonstrated the validity and intra-rater reliability of the digitally adapted pressure algometer. Inter-rater reliability results were moderate (r = 0.55-0.60; Cronbach's alpha = 0.71-0.75). Conclusion: The adapted pressure algometer provide valid and reliable measurements of pressure pain threshold. The results support more widespread use of the pressure pain threshold method among clinicians.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain
    Skordis, Charalampos
    Liaskou, Christina
    Papagiakoumou, Evangelia
    Sotiropoulos, Spyridon
    Plavoukou, Theodora
    Karakasidou, Palina
    Georgoudis, George
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [2] Intra and Inter-Rater Reliability of a Novel Isometric Test of Neck Strength
    McBride, Lesley
    James, Rob S.
    Alsop, Sian
    Oxford, Samuel W.
    SPORTS, 2023, 11 (01)
  • [3] Validity, responsiveness, intra- and inter-rater reliability of the weighted tape measure when measuring digital circumference
    Jansen, Victoria
    Radbourne, Liz
    Fakis, Apostolos
    Bradley, Mary
    Burke, Frank
    Ellis, Jo
    HAND THERAPY, 2010, 15 (02) : 31 - 38
  • [4] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [5] Tele-Assessment of Functional Capacity: Validity, Intra- and Inter-rater Reliability
    Asliyüce, Yasemin Ozel
    Fanuscu, Aybuke
    Asliyüce, Abdurahim
    Ülger, Ozlem
    WORKPLACE HEALTH & SAFETY, 2023, 71 (10) : 476 - 483
  • [6] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [7] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [8] The Scarbase Duo®: Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool
    Fell, Matthew
    Meirte, Jill
    Anthonissen, Mieke
    Maertens, Koen
    Pleat, Jonathon
    Moortgat, Peter
    BURNS, 2016, 42 (02) : 336 - 344
  • [9] Intra- and inter-rater reliability of digital image analysis for skin color measurement
    Sommers, Marilyn
    Beacham, Barbara
    Baker, Rachel
    Fargo, Jamison
    SKIN RESEARCH AND TECHNOLOGY, 2013, 19 (04) : 484 - 491
  • [10] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476