3D spin-lock imaging of human gliomas

被引:49
|
作者
Aronen, HJ [1 ]
Ramadan, UA [1 ]
Peltonen, TK [1 ]
Markkola, AT [1 ]
Tanttu, JI [1 ]
Jääskeläinen, J [1 ]
Häkkinen, AM [1 ]
Sepponen, R [1 ]
机构
[1] Univ Helsinki, Cent Hosp, Dept Radiol, FIN-00290 Helsinki, Finland
关键词
spin lock imaging; brain tumors; contrast agents; Gd-DTPA;
D O I
10.1016/S0730-725X(99)00041-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated whether the simultaneous use of paramagnetic contrast medium and 3D on-resonance spin lock (SL) imaging could improve the contrast of enhancing brain tumors at 0.1 T, A phantom containing serial concentrations of gadopentetate dimeglumine (Gd-DTPA) in cross-linked bovine serum albumin (BSA) was imaged. Eleven patients with histologically verified glioma were also studied. T-1-weighted 3D gradient echo images with and without SL pulse were acquired before and after a Gd-DTPA injection. SL effect, contrast, and contrast-to-noise ratio (CNR) were calculated for each patient, In the glioma patients, the SL effect was significantly smaller in the tumor than in the white and gray matter both before (p = 0.001, p = 0.025, respectively), and after contrast medium injection (p < 0.001,p < 0.001, respectively). On post-contrast images, SL imaging significantly improved tumor contrast (p = 0.001) whereas tumor CNR decreased slightly (p = 0.024). The combined use of SL imaging and paramagnetic Gd-DTPA contrast agent offers a modality for improving tumor contrast in magnetic resonance imaging (MRI) of enhancing brain tumors. 3D gradient echo SL imaging has also shown potential to increase tissue characterization properties of MR imaging of human gliomas, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1001 / 1010
页数:10
相关论文
共 50 条
  • [21] SPIN-LOCK SYNCHRONIZATION ON THE BUTTERFLY AND KSR1
    ZHANG, XD
    CASTANEDA, R
    CHAN, EW
    IEEE PARALLEL & DISTRIBUTED TECHNOLOGY, 1994, 2 (01): : 51 - 63
  • [22] Artifacts correction for T1rho imaging with constant amplitude spin-lock
    Chen, Weitian
    JOURNAL OF MAGNETIC RESONANCE, 2017, 274 : 13 - 23
  • [23] 3D Pseudocontinuous Arterial Spin-Labeling MR Imaging in the Preoperative Evaluation of Gliomas
    Zeng, Q.
    Jiang, B.
    Shi, F.
    Ling, C.
    Dong, F.
    Zhang, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (10) : 1876 - 1883
  • [24] Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH
    Zu, Zhongliang
    Li, Hua
    Jiang, Xiaoyu
    Gore, John C.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 298 - 305
  • [25] Study of Magnetization Evolution by Using Composite Spin-lock Pulses for T1ρ Imaging
    Li, Yujia
    Zhao, Feng
    Wang, Yi-Xiang
    Ahuja, Anil T.
    Yuan, Jing
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 408 - 411
  • [26] MR angiography using spin-lock flow tagging
    Azhari, H
    McKenzie, CA
    Edelman, RR
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 1041 - 1044
  • [27] Spin-Lock Imaging for Direct Detection of Oscillating Magnetic Fields with MRI: Simulations and Phantom Studies
    Nagahara, Shizue
    Ueno, Masahito
    Kobayashi, Tetsuo
    ADVANCED BIOMEDICAL ENGINEERING, 2013, 2 (02): : 63 - 71
  • [28] Direct fMRI by random spin-lock along the neural field
    De Luca, Francesco
    MAGNETIC RESONANCE IMAGING, 2011, 29 (07) : 951 - 957
  • [29] Incorporating implementation overheads in the analysis for the Flexible Spin-Lock Model
    Balasubramanian, S. M. N.
    Afshar, Sara
    Gai, Paolo
    Behnam, Moris
    Bril, Reinder J.
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 8411 - 8418
  • [30] Improved magnetization alignment schemes for spin-lock relaxation experiments
    Hansen, D. Flemming
    Kay, Lewis E.
    JOURNAL OF BIOMOLECULAR NMR, 2007, 37 (04) : 245 - 255