A sensitive and specific method for isoniazid determination based on selective adsorption using an isoniazid ion-selective piezoelectric sensor

被引:26
|
作者
Yao, SZ [1 ]
Li, WF
Su, XL
Zuo, XB
Wei, WZ
机构
[1] Hunan Normal Univ, Inst Chem Res, Changsha 410081, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
关键词
isoniazid; ISP sensor; pharmaceutical detection; tuberculosis;
D O I
10.1016/S0039-9140(99)00133-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective, sensitive and simple ion-selective piezoelectric (ISP) sensor was developed for the direct determination of isoniazid (INH) in body fluids. Based on sensitive mass response of piezoelectric quartz crystal and selective adsorption/desorption across the modified film, the ISP sensor was fabricated by coating a PVC film containing activant on one electrode of a thickness-shear mode piezoelectric quartz crystal. The observed frequencies of ISP sensor were found to decrease with the increase of the INH concentration in a 0.1 M NaNO3 solution. In this paper, three activants, INH-phosphotungstate (I), INH-silicotungstate (II), and INH-[BiI4](-) (III), were synthesized and investigated. Calibration graphs were linear from 6 x 10(-8) to 2 x 10(-3) M for I, 2 x 10(-7) to 2 x 10(-3) M for II and 2 x 10(-7) to 2 x 10(-3) M for III, with detection limits 6 x 10(-8) M for 1, 2 x 10(-7) M for II and 2 x 10(-7) M for III, in a 0.1 M NaNO3 solution at pH 7.0 and 37 degrees C. Recoveries were from 98% to 102% with R.S.D. up to 2%. Results for real samples obtained by the proposed method agreed well with those obtained by the conventional pharmacopeia method. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 50 条
  • [21] ION-SELECTIVE ELECTRODE METHOD FOR DETERMINATION OF BONE FLUORIDE
    POCHOMIS, AM
    GRIFFITH, FD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1971, 32 (08): : 557 - &
  • [22] DETERMINATION OF ETHAVERINE AND PAPAVERINE USING ION-SELECTIVE ELECTRODES
    EPPELSHEIM, C
    AUBECK, R
    HAMPP, N
    BRAUCHLE, C
    ANALYST, 1991, 116 (10) : 1001 - 1003
  • [23] Determination of drug substances using ion-selective electrodes
    Katsu, T
    Watanabe, K
    JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1996, 42 (06): : 453 - 467
  • [24] DETERMINATION OF FLUORIDE IN TOOTHPASTE USING AN ION-SELECTIVE ELECTRODE
    LIGHT, TS
    CAPPUCCINO, CC
    JOURNAL OF CHEMICAL EDUCATION, 1975, 52 (04) : 247 - 250
  • [25] DETERMINATION OF TRIMECAINE AND LIDOCAINE USING AN ION-SELECTIVE ELECTRODE
    KEREICHUK, AS
    PANTSURKIN, VI
    PTUKHA, EV
    POTEMKIN, KD
    CHEKRYSHKINA, LA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (03): : 409 - 413
  • [26] DETERMINATION OF NONIONOGENIC SURFACTANTS USING ION-SELECTIVE ELECTRODES
    IVANOV, VN
    PRAVSHIN, YS
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1986, 41 (02): : 291 - 295
  • [27] DETERMINATION OF SULFIDES IN WATERS USING ION-SELECTIVE ELECTRODE
    WEISS, D
    CHEMICKE LISTY, 1974, 68 (05): : 528 - 534
  • [28] RAPID METHOD FOR DETERMINATION OF CHLORINE IN SILICATE ROCKS USING ION-SELECTIVE ELECTRODES
    HAYNES, SJ
    CLARK, AH
    ECONOMIC GEOLOGY, 1972, 67 (03) : 378 - &
  • [29] Fabrication of butyrylcholinesterase sensor using polyurethane-based ion-selective membranes
    Cho, YA
    Lee, HS
    Cha, GS
    Lee, YT
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (04): : 435 - 438
  • [30] An Isoniazid Based Schiff Base Sensor for Selective Detection of Pd2+ Ions
    Singh, Jasbir
    Saini, Shubham
    Chauhan, Ravish K.
    Bhardwaj, Pallavi
    Kumar, Ashwani
    Virender
    JOURNAL OF FLUORESCENCE, 2025, 35 (01) : 21 - 28