A sensitive and specific method for isoniazid determination based on selective adsorption using an isoniazid ion-selective piezoelectric sensor

被引:26
|
作者
Yao, SZ [1 ]
Li, WF
Su, XL
Zuo, XB
Wei, WZ
机构
[1] Hunan Normal Univ, Inst Chem Res, Changsha 410081, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
关键词
isoniazid; ISP sensor; pharmaceutical detection; tuberculosis;
D O I
10.1016/S0039-9140(99)00133-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective, sensitive and simple ion-selective piezoelectric (ISP) sensor was developed for the direct determination of isoniazid (INH) in body fluids. Based on sensitive mass response of piezoelectric quartz crystal and selective adsorption/desorption across the modified film, the ISP sensor was fabricated by coating a PVC film containing activant on one electrode of a thickness-shear mode piezoelectric quartz crystal. The observed frequencies of ISP sensor were found to decrease with the increase of the INH concentration in a 0.1 M NaNO3 solution. In this paper, three activants, INH-phosphotungstate (I), INH-silicotungstate (II), and INH-[BiI4](-) (III), were synthesized and investigated. Calibration graphs were linear from 6 x 10(-8) to 2 x 10(-3) M for I, 2 x 10(-7) to 2 x 10(-3) M for II and 2 x 10(-7) to 2 x 10(-3) M for III, with detection limits 6 x 10(-8) M for 1, 2 x 10(-7) M for II and 2 x 10(-7) M for III, in a 0.1 M NaNO3 solution at pH 7.0 and 37 degrees C. Recoveries were from 98% to 102% with R.S.D. up to 2%. Results for real samples obtained by the proposed method agreed well with those obtained by the conventional pharmacopeia method. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 50 条
  • [1] Preparation and application of chlorpheniramine ion-selective piezoelectric sensor based on selective adsorption
    Long, YM
    Li, WF
    Nie, LH
    Yao, SZ
    ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) : 33 - 40
  • [2] Determination of isoniazid using mercury(II) ion selective membrane electrode
    Srivastava, Bharti
    Chattopadhyaya, M. C.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (10) : 1615 - 1618
  • [3] Determination of benzydamine hydrochloride in serum and urine by using a benzydamine ion-selective piezoelectric sensor
    Li, WF
    Su, XL
    Zhang, H
    Nie, LH
    Yao, SH
    ANALYTICAL SCIENCES, 1998, 14 (05) : 955 - 960
  • [4] Determination of Benzydamine Hydrochloride in Serum and Urine by Using a Benzydamine Ion-Selective Piezoelectric Sensor
    Weifeng Li
    Xiaoli Su
    Hong Zhang
    Lihua Nie
    Shuozhuo Yao
    Analytical Sciences, 1998, 14 : 955 - 960
  • [5] Rapid, specific and sensitive method for isoniazid determination in serum
    Sadeg, N
    Pertat, N
    Dutertre, H
    Dumontet, M
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 675 (01): : 113 - 117
  • [6] A SIMPLE, SENSITIVE METHOD FOR DETERMINATION OF BONE FLUORIDE USING AN ION-SELECTIVE ELECTRODE
    POCHOMIS, AM
    GRIFFITH, FD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (02): : 6 - &
  • [7] INDIRECT POTENTIOMETRIC DETERMINATION OF HYDRAZINE, ISONIAZID, SULFIDE AND THIOSULFATE WITH A CHLORAMINE-T ION-SELECTIVE ELECTRODE
    KOUPPARIS, MA
    HADJIIOANNOU, TP
    TALANTA, 1978, 25 (08) : 477 - 480
  • [8] Preparation and application of a trimethoprim ion-selective piezoelectric sensor
    Li, WF
    Su, XL
    Guo, HJ
    Wei, WZ
    Yao, SH
    ANALYST, 1999, 124 (01) : 91 - 95
  • [9] A HIGHLY SELECTIVE METHOD FOR THE DETERMINATION OF ALBUMIN BASED ON A FLUORIDE ION-SELECTIVE ELECTRODE
    GREY, H
    MANGAN, C
    BROCHOT, J
    SIDDIQI, I
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1190 - 1190
  • [10] Selective determination of isoniazid using bentonite clay modified electrodes
    Azad, Uday Pratap
    Prajapati, Nandlal
    Ganesan, Vellaichamy
    BIOELECTROCHEMISTRY, 2015, 101 : 120 - 125