STRUCTURAL IDENTIFICATION OF DAMAGED ANIME SANTE CHURCH USING AMBIENT VIBRATION, FORCED VIBRATION AND EARTHQUAKE ACTION

被引:0
|
作者
Boscato, Giosue [1 ]
Dal Cin, Alessandra [1 ]
Rocchi, Davide [1 ]
Russo, Salvatore [1 ]
Sciarretta, Francesca [1 ]
Sperotto, Elena [1 ]
Tommasini, Mauro
机构
[1] IUAV Univ Venice, Venice, Italy
关键词
Historical Church; Dynamic testing; Modal parameters; FEM analysis;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Anime Sante Church is an historical building of L'Aquila, it was built in 1713. The Church was stricken and damaged by earthquake's mainshock of April 6, 2009. This paper presents the procedure for the structural identification using different vibration testing with stationary signal and with transient. Ambient vibrations, seismic events and impact force tests were used to measure the dynamical properties of the Church. The vibrations of all dynamic testing were recorded and the identified modal parameters were used to calibrate a FE model of the structure. The correlation between the experimental and numerical results validates the kind of monitoring. As a matter of fact, the use of multiple modes of excitation optimizes the results and improving the calibration of the FE model.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 50 条
  • [1] On the monitoring of historic Anime Sante church damaged by earthquake in L'Aquila
    Russo, Salvatore
    STRUCTURAL CONTROL & HEALTH MONITORING, 2013, 20 (09): : 1226 - 1239
  • [2] Forced vibration testing of bridge damaged in the 2010 Darfield Earthquake
    Hogan, L. S.
    Wotherspoon, L. M.
    Beskhyroun, S.
    Ingham, J. M.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2449 - 2456
  • [3] Ambient Vibration Test on Earthquake Damaged R/C Building Structures
    Dai, Junwu
    Yang, Yongqiang
    Wang, Duozhi
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2576 - 2579
  • [4] Ambient and forced vibration testing with numerical identification for RC buildings
    Aras, Fuat
    EARTHQUAKES AND STRUCTURES, 2016, 11 (05) : 809 - 822
  • [5] Identification of Modal Parameters of a Multistoried RC Building Using Ambient Vibration and Strong Vibration Records of Bhuj Earthquake, 2001
    Singh, J. P.
    Agarwal, Pankaj
    Kumar, Ashok
    Thakkar, S. K.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (03) : 444 - 457
  • [6] Structural identification from ambient vibration measurement using the multivariate AR model
    Huang, CS
    JOURNAL OF SOUND AND VIBRATION, 2001, 241 (03) : 337 - 359
  • [7] Dynamic behaviour of a 13-story reinforced concrete building under ambient vibration, forced vibration, and earthquake excitation
    Beskhyroun, Sherif
    Navabian, Niusha
    Wotherspoon, Liam
    Ma, Quincy
    JOURNAL OF BUILDING ENGINEERING, 2020, 28
  • [8] Identification of linear structural systems using earthquake-induced vibration data
    Luş, H.
    Betti, R.
    Longman, R.W.
    Earthquake Engineering and Structural Dynamics, 1999, 28 (11): : 1449 - 1467
  • [9] Identification of linear structural systems using earthquake-induced vibration data
    Lus, H
    Betti, R
    Longman, RW
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1999, 28 (11): : 1449 - 1467
  • [10] Fast Bayesian approach for modal identification using forced vibration data considering the ambient effect
    Ni, Yan-Chun
    Zhang, Feng-Liang
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 105 : 113 - 128