Energy transfer procession in an air source heat pump unit during defrosting with melted frost locally drainage in its multi-circuit outdoor coil

被引:25
|
作者
Song, Mengjie [1 ]
Dang Chaobin [1 ]
Ning, Mao [2 ]
Deng Shiming [3 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Dept Human & Engn Environm Studies, Tokyo, Japan
[2] China Univ Petr East China, Coll Pipeline & Civil Engn, Qingdao, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金; 日本学术振兴会;
关键词
Melted frost locally drainage; Frosting evenness value; Metal energy storage; Reverse cycle defrosting; Air source heat pump; Multi-circuit outdoor coil; PERFORMANCE IMPROVEMENT; LOUVERED-FIN; SYSTEM; EXCHANGER; REFRIGERANT; SURFACE; FLOW; EVAPORATORS; CYCLES; ANGLE;
D O I
10.1016/j.enbuild.2018.01.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air source heat pump (ASHP) units are widely used in recent years, and reverse cycle defrosting becomes the most popular method to solve their undesired frosting problem. During defrosting, a transient and nonlinear heat and mass transfer procession, the metal energy stored in the indoor and outdoor coils are varying as their temperature fluctuations. On the other hand, authors have previously confirmed the effects of melted frost and metal energy storage on system defrosting performance. However, detailed energy transfer procession without melted frost influence is still not identified. This fundamental problem directly affects the development and modification of two coils in a novel ASHP unit or an existing one. Consequently, basing on frost evenly accumulated on each circuit's surface, two cases were thereby designed in this study. Experimental results show that, the heating supply of indoor air thermal energy contributed about 80% of the total energy usage for defrosting, nearly 90% of energy consumed on frost melting and ambient air heating, respectively. After the total area of outdoor coil was enlarged by 50%, the metal energy storage effect was changed from -0.44% to -3.67%. Meanwhile, defrosting efficiency was improved by 11.66%, from 47.13% to 58.79%. Contributions of this study can effectively guide the design optimization of an ASHP unit, improve occupant's thermal comfort and promote the energy saving in buildings and industry. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 120
页数:12
相关论文
共 24 条
  • [1] An experimental study on the effects of downwards flowing of melted frost over a vertical multi-circuit outdoor coil in an air source heat pump on defrosting performance during reverse cycle defrosting
    Song, Mengjie
    Deng, Shiming
    Pan, Dongmei
    Mao, Ning
    [J]. APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 258 - 265
  • [2] An experimental study on the negative effects of downwards flow of the melted frost over a multi-circuit outdoor coil in an air source heat pump during reverse cycle defrosting
    Song Mengjie
    Pan Dongmei
    Li Ning
    Deng Shiming
    [J]. APPLIED ENERGY, 2015, 138 : 598 - 604
  • [3] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [4] Energy transfer procession in an air source heat pump unit during defrosting
    Song Mengjie
    Xu Xiangguo
    Mao Ning
    Deng Shiming
    Xu Yingjie
    [J]. APPLIED ENERGY, 2017, 204 : 679 - 689
  • [5] An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil
    Song Mengjie
    Deng Shiming
    Mao Ning
    Ye Xianming
    [J]. APPLIED ENERGY, 2016, 165 : 371 - 382
  • [6] A semi-empirical modeling study on the defrosting performance for an air source heat pump unit with local drainage of melted frost from its three-circuit outdoor coil
    Song Mengjie
    Deng Shiming
    Xia Liang
    [J]. APPLIED ENERGY, 2014, 136 : 537 - 547
  • [7] Techno-economic analysis on frosting/defrosting operations for an air source heat pump unit with an optimized multi-circuit outdoor coil
    Song, Mengjie
    Tso, Chiyan
    Chao, Christopher Yuhang
    Wu, Chili
    [J]. ENERGY AND BUILDINGS, 2018, 166 : 165 - 177
  • [8] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part I: Experiments
    Qu Minglu
    Xia Liang
    Deng Shiming
    Jiang Yiqiang
    [J]. APPLIED ENERGY, 2012, 91 (01) : 122 - 129
  • [9] An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values
    Song, Mengjie
    Chen, Ailu
    Mao, Ning
    [J]. APPLIED THERMAL ENGINEERING, 2016, 94 : 331 - 340
  • [10] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part II: Modeling analysis
    Qu, Minglu
    Pan, Dongmei
    Xia, Liang
    Deng, Shiming
    Jiang, Yiqiang
    [J]. APPLIED ENERGY, 2012, 91 (01) : 274 - 280