A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part I: Experiments

被引:78
|
作者
Qu Minglu [1 ]
Xia Liang [1 ]
Deng Shiming [1 ]
Jiang Yiqiang [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[2] Harbin Inst Technol, Inst Heat Pump & Air Conditioning Technol, Harbin 150006, Peoples R China
关键词
Experiment; Air source heat pump; Reverse cycle defrost; Defrosting efficiency; Multiple parallel refrigerant circuits; IDEALIZED MODEL; FROST;
D O I
10.1016/j.apenergy.2011.08.034
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
When an air source heat pump (ASHP) unit operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil which normally has multiple parallel circuits on its refrigerant side for minimized refrigerant pressure loss and enhanced heat transfer efficiency. On its airside, however, there is usually no segmentation corresponding to the number of refrigerant circuit. Frosting deteriorates the operation and energy efficiency of the ASHP unit and periodic defrosting becomes necessary. Currently the most widely used standard defrosting method for ASHPs is reverse cycle defrost. This paper, the first part of a two-part series, reports on the experimental part of a study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an experimental 6.5 kW heating capacity residential ASHP unit. Firstly the experimental ASHP unit is described and experimental procedures detailed. Secondly, the experimental results are reported. This is followed by the discussion on the effects of downwards flowing of the melted frost along a multi-circuit outdoor coil surface on defrosting performance. Finally, the evaluation of the defrosting efficiency for the experimental ASHP unit is provided. In the second part of the series, a modeling analysis on the effects of downwards flowing of the melted frost along the multi-circuit outdoor coil surface on defrosting performance of the experimental ASHP unit will be presented. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:122 / 129
页数:8
相关论文
共 50 条
  • [1] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part II: Modeling analysis
    Qu, Minglu
    Pan, Dongmei
    Xia, Liang
    Deng, Shiming
    Jiang, Yiqiang
    [J]. APPLIED ENERGY, 2012, 91 (01) : 274 - 280
  • [2] An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil
    Song Mengjie
    Deng Shiming
    Mao Ning
    Ye Xianming
    [J]. APPLIED ENERGY, 2016, 165 : 371 - 382
  • [3] An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values
    Song, Mengjie
    Chen, Ailu
    Mao, Ning
    [J]. APPLIED THERMAL ENGINEERING, 2016, 94 : 331 - 340
  • [4] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [5] An experimental study on the uneven refrigerant distribution over a vertically installed multi-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting
    Song, Mengjie
    Wang, Zhihua
    Mao, Ning
    Li, Zhao
    Chen, Ying
    [J]. APPLIED THERMAL ENGINEERING, 2015, 91 : 975 - 985
  • [6] An experimental study on the effects of downwards flowing of melted frost over a vertical multi-circuit outdoor coil in an air source heat pump on defrosting performance during reverse cycle defrosting
    Song, Mengjie
    Deng, Shiming
    Pan, Dongmei
    Mao, Ning
    [J]. APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 258 - 265
  • [7] An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil
    Song Mengjie
    Xia Liang
    Mao Ning
    Deng Shiming
    [J]. APPLIED ENERGY, 2016, 164 : 36 - 44
  • [8] Review on the optimization studies of reverse cycle defrosting for air source heat pump units with multi-circuit outdoor coils
    Song, Mengjie
    Tian, Yueyang
    Zhang, Long
    Dang, Chaobin
    Hu, Yanxin
    Xu, Yingjie
    Shen, Limei
    Zhan, Tianzhuo
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2023, 20 (12) : 1401 - 1422
  • [9] An experimental study on performance during reverse cycle defrosting of an air source heat pump with a horizontal three circuit outdoor coil
    Song Mengjie
    Xu Xiangguo
    Deng Shiming
    Mao Ning
    [J]. INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 92 - 95
  • [10] An experimental study on the negative effects of downwards flow of the melted frost over a multi-circuit outdoor coil in an air source heat pump during reverse cycle defrosting
    Song Mengjie
    Pan Dongmei
    Li Ning
    Deng Shiming
    [J]. APPLIED ENERGY, 2015, 138 : 598 - 604