Space radiation absorbed dose distribution in a human phantom

被引:1
|
作者
Badhwar, GD
Atwell, W
Badavi, FF
Yang, TC
Cleghorn, TF
机构
[1] Boeing Co, Houston, TX 77058 USA
[2] NASA, Lyndon B Johnson Space Ctr, Houston, TX 77058 USA
[3] Christopher Newport Univ, Hampton, VA 23681 USA
关键词
D O I
10.1667/0033-7587(2002)157[0076:SRADDI]2.0.CO;2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality, factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65degrees inclination and similar to380 km altitude) of a fully, instrumented Alderson Rando(TM) phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 I-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body,. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity, of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully, understood. Passive measurements using Li-6- and Li-7-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study. (C) 2002 by Radiation Research Society.
引用
收藏
页码:76 / 91
页数:16
相关论文
共 50 条
  • [21] A method for calculation of absorbed radiation dose
    Gryaznov A.Yu.
    Potrakhov N.N.
    Biomedical Engineering, 2006, 40 (4) : 183 - 186
  • [22] ABSORBED DOSE AND CRE IN RADIATION SYNOVECTOMY
    KULKARNI, NS
    AQUINO, JA
    ASUNCION, JR
    SINGH, SB
    MEDICAL PHYSICS, 1981, 8 (05) : 739 - 739
  • [23] METHODS OF CALCULATING RADIATION ABSORBED DOSE
    WEGST, AV
    NUCLEAR MEDICINE AND BIOLOGY, 1987, 14 (03): : 269 - 271
  • [24] Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: a Phantom Study with Radiochromic Films
    Russo, Paolo
    Coppola, Teresa
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3463 - 3470
  • [25] Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: A Phantom Study With Radiochromic Films
    Russo, Paolo
    Coppola, Teresa
    Mettivier, Giovanni
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2220 - 2229
  • [27] A METHOD OF MEASURING TISSUEEQUIVALENT ABSORBED DOSE (LET) AND DEPTH-DOSE DISTRIBUTION PARTICULARLY IN SPACE FLIGHT
    CHAPMAN, MC
    HOLLY, FE
    HEALTH PHYSICS, 1966, 12 (12): : 1796 - +
  • [28] COMPUTATION OF DISTRIBUTION OF ABSORBED DOSE AND ABSORBED DOSE RATE FROM A SCANNING ELECTRON BEAM
    ROZENFEL.M
    LANZL, LH
    NEWTON, CM
    SKAGGS, LS
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 140 - &
  • [29] Site - Specific Skeletal Dosimetry: From Mean Absorbed Dose to Absorbed Dose Distribution
    Papanikolos, G.
    Lyra, M.
    Kontogeorgakos, D.
    Jordanou, J.
    Vlahos, L.
    Limouris, G. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207
  • [30] COMPUTATION OF DISTRIBUTION OF ABSORBED DOSE AND ABSORBED DOSE RATE FROM A SCANNING ELECTRON BEAM
    ROZENFELD, M
    LANZL, LH
    NEWTON, CM
    SKAGGS, LS
    STRAHLENTHERAPIE, 1969, 138 (06) : 651 - +