A Retrospective Study of the Clinical Performance of Porcelain-Fused-to-Metal Resin-Bonded Fixed Partial Dentures

被引:0
|
作者
Boening, Klaus W. [1 ]
Ullmann, Katrin [1 ]
机构
[1] Tech Univ Dresden, Dept Prosthet Dent, Univ Hosp Carl Gustav Carus, D-01307 Dresden, Germany
关键词
LONG-TERM SURVIVAL; 13-YEAR FOLLOW-UP; CAST METAL; BRIDGES; ANTERIOR; PROSTHESES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated the clinical performance of resin-bonded fixed partial dentures (RBFPDs) using minimally invasive, nonretentive abutment tooth preparation. Materials and Methods: Forty-four patients received 56 porcelain-fused-to-metal RBFPDs (52 three-unit RBFPDs, 4 four-unit RBFPDs). All RBFPDs were inserted between 1995 and 2010 according to a standardized protocol. Thirty-eight RBFPDs replaced anterior teeth in the maxilla, 18 RBFPDs replaced anterior teeth in the mandible, and 3 RBFPDs replaced premolars (1 maxillary, 2 mandibular). At annual recall appointments, RBFPDs were carefully inspected for technical and biologic failures or complications (eg, debonding, abutment tooth caries). Results: The mean observation period was 76 months, with a minimum of 4 months and a maximum of 198 months. Five RBFPDs debonded. Further complications comprised one instance of porcelain chipping and one caries lesion underneath a loose retainer. One patient was dissatisfied with the esthetic appearance of her RBFPD. The cumulative survival rate with the event "debonding" dropped to 90% after 23 months and then remained constant. Survival rate with the event "any restoration complication" dropped to 84% after 77 months and then remained constant. Conclusions: With regard to the high patient satisfaction and relatively low incidence of failures and complications, the clinical performance of nonretentive RBFPDs can be considered satisfactory. Hence, within the limitations of this study, the data justify nonretentive RBFPDs as long-term provisional restorations. lot J Prosthodont 2012;25:265-269.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 50 条
  • [41] Resin-bonded fixed partial dentures - A literature review with presentation of a novel approach
    El-Mowafy, O
    Rubo, MHM
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (06) : 460 - 467
  • [42] The current status of the design of resin-bonded fixed partial dentures, splints and overcastings
    Shimizu, Hiroshi
    Kawaguchi, Tomohiro
    Takahashi, Yutaka
    JAPANESE DENTAL SCIENCE REVIEW, 2014, 50 (02) : 23 - 28
  • [43] Risk of debonding in three-unit resin-bonded fixed partial dentures
    Kerschbaum, T
    Haastert, B
    Marinello, CP
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (03): : 248 - 253
  • [44] Longevity of two-unit cantilevered resin-bonded fixed partial dentures
    Botelho, MG
    Chan, AWK
    Yiu, EYL
    Tse, ETP
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (05): : 295 - 299
  • [45] Fracture characteristics of anterior resin-bonded zirconia-fixed partial dentures
    Rosentritt, Martin
    Ries, Stefan
    Kolbeck, Carola
    Westphal, Maria
    Richter, Ernst-Juergen
    Handel, Gerhard
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) : 453 - 457
  • [46] Retainer design for posterior resin-bonded fixed partial dentures: A technical report
    Shimizu, H
    Takahashi, Y
    QUINTESSENCE INTERNATIONAL, 2004, 35 (08): : 653 - 654
  • [47] 10-year follow-up study of resin-bonded fixed partial dentures
    Wiethoff, B
    Henrich, GM
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1183 - 1183
  • [48] MARGINAL DISCREPANCY CHANGES AT VARIOUS STAGES OF CONSTRUCTION OF 3-UNIT PORCELAIN-FUSED-TO-METAL FIXED PARTIAL DENTURES
    FELTON, DA
    SULIK, WD
    HOLLAND, GA
    TAYLOR, DF
    BAYNE, SC
    DENTAL MATERIALS, 1988, 4 (05) : 296 - 301
  • [50] 11-year follow-up study of resin-bonded fixed partial dentures
    Probster, B
    Henrich, GM
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1997, 10 (03) : 259 - 268