Clinical value of 24-hour delayed imaging in somatostatin receptor scintigraphy for meningioma

被引:0
|
作者
Klutmann, S
Bohuslavizki, KH
Tietje, N
Kröger, S
Behnke, A
Brenner, W
Mester, J
Henze, E
Clausen, M
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Nucl Med, D-20246 Hamburg, Germany
[2] Univ Kiel, Clin Nucl Med, Kiel, Germany
[3] Univ Kiel, Clin Neurosurg, Kiel, Germany
关键词
somatostatin receptor scintigraphy; In-111-octreotide; meningioma; delayed imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Somatostatin receptor scintigraphy (SRS) using In-111-octreotide has proven useful in patients suspected of having meningiomas. Delayed imaging is regularly performed up to 24 h postinjection. However, this procedure is time consuming and expensive. Therefore, we investigated whether 24-h imaging may be omitted in these patients. Methods: After clinical examination and standard MRI, 71 patients were suspected of having 92 meningioma lesions. Before surgery, all patients underwent SRS after intravenous injection of 200 MBq (5.4 mCi) In-111-octreotide. Planar whole-body images were obtained at 10 min and 1, 4 and 24 h, and SPECT was performed at 4 and 24 h. Results of SRS in all lesions were evaluated with respect to histology and time of image acquisition. Results: SRS yielded 58 true-positive, 20 true-negative and 14 false-negative results, with the false-negatives all less than 5 mL(2.3 +/- 2.1 mL) in volume. In 52 of 58 true-positive lesions (89.7%), diagnosis could be established by 4-h imaging without further information by 24-h imaging. In 10 of the 52 lesions, SPECT was necessary to confirm planar findings. Imaging at 24 h was necessary in only 6 of 58 true-positive lesions (10.3%): 3 patients who had intracranial relapse of meningioma (volume < 5 mt) and 3 who had spinal meningioma. Thus, a diagnosis of intracranial meningioma could be established in 52 of 55 lesions (95%) using a 4-h imaging protocol. Conclusion: With a 4-h acquisition protocol that includes SPEGT imaging, SRS yields sufficient information in patients suspected of having intracranial meningiomas. Delayed imaging at 24 h is recommended only for patients who have small meningiomas (volume < 5 mL), spinal localizations or negative SRS at 4 h.
引用
收藏
页码:1246 / 1251
页数:6
相关论文
共 50 条
  • [21] Somatostatin receptor scintigraphy in postsurgical follow-up examinations of meningioma
    Klutmann, S
    Bohuslavizki, KH
    Brenner, W
    Behnke, A
    Tietje, N
    Kröger, S
    Hugo, HH
    Mehdorn, HM
    Clausen, M
    Henze, E
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (11) : 1913 - 1917
  • [22] DEEP VENOUS THROMBOPHLEBITIS - DETECTION WITH 4-HOUR VERSUS 24-HOUR PLATELET SCINTIGRAPHY
    SEABOLD, JE
    CONRAD, GR
    PONTO, JA
    KIMBALL, DA
    FREY, EE
    AHMED, F
    COUGHLAN, JD
    JENSEN, KC
    RADIOLOGY, 1987, 165 (02) : 355 - 360
  • [23] Clinical and diagnostical value of 24-hour arterial stiffness monitoring in patients with bronchial asthma
    Karoli, N. A.
    Zarmanbetova, O. T.
    Rebrov, A. P.
    TERAPEVTICHESKII ARKHIV, 2020, 92 (03) : 30 - 35
  • [24] Value of 24-Hour Delayed Film of Barium Enema for Colon Transit Function in Young Children With Constipation
    Bae, Sun Hwan
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S594 - S594
  • [25] An Integrated Enhancement Solution for 24-Hour Colorful Imaging
    Lv, Feifan
    Zheng, Yinqiang
    Li, Yicheng
    Lu, Feng
    THIRTY-FOURTH AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE, THE THIRTY-SECOND INNOVATIVE APPLICATIONS OF ARTIFICIAL INTELLIGENCE CONFERENCE AND THE TENTH AAAI SYMPOSIUM ON EDUCATIONAL ADVANCES IN ARTIFICIAL INTELLIGENCE, 2020, 34 : 11725 - 11732
  • [26] Optimization of somatostatin receptor imaging with In-111 pentetreotide scintigraphy: a phantom study & clinical imaging
    Kamiya, Takashi
    Fujino, Kouichi
    Ikuta, Rie
    Ogushi, Gaku
    Isohashi, Kayako
    Matsunaga, Keiko
    Kato, Hiroki
    Tatsumi, Mitsuaki
    Watabe, Tadashi
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [27] OPTIMAL IDENTIFICATION OF MYOCARDIAL VIABILITY WITH SPECT - 24-HOUR REDISTRIBUTION THALLIUM SCINTIGRAPHY IS SUPERIOR TO REST SESTAMIBI IMAGING
    TAYLOR, AM
    MERHIGE, ME
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P23 - P24
  • [28] Value of somatostatin receptor scintigraphy for preoperative localization of carcinoids
    Kisker, O
    Weinel, RJ
    Geks, J
    Zacara, F
    Joseph, K
    Rothmund, M
    WORLD JOURNAL OF SURGERY, 1996, 20 (02) : 162 - 167
  • [29] Delayed 24-hour LeukoScan imaging improves the technique specificity for diagnosis of acute infection of knee prosthesis
    Cittadin, S.
    Massaro, A.
    Banti, E.
    Rampin, L.
    Rubello, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S155 - S156
  • [30] Value of somatostatin receptor scintigraphy: A prospective study in gastrinoma of its effect on clinical management
    Termanini, B
    Gibril, F
    Reynolds, JC
    Doppman, JL
    Chen, CC
    Stewart, CA
    Sutliff, VE
    Jensen, RT
    GASTROENTEROLOGY, 1997, 112 (02) : 335 - 347