Efficacy of Trial Fitting and Software Fitting for Orthokeratology Lens: One-Year Follow-Up Study

被引:7
|
作者
Lu, Daqian [1 ,2 ]
Gu, Tianpu [1 ,2 ]
Lin, Weiping [1 ,2 ]
Li, Na [1 ,2 ]
Gong, Boteng [1 ,2 ]
Wei, Ruihua [1 ,2 ]
机构
[1] Tianjin Med Univ, Eye Hosp, Tianjin, Peoples R China
[2] Tianjin Med Univ, Tianjin, Peoples R China
来源
关键词
Orthokeratology lens; Trial fitting and software fitting; Efficacy; MYOPIA; CHILDREN; PROGRESSION; ANTERIOR;
D O I
10.1097/ICL.0000000000000539
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To observe and compare the clinical efficacy of 1-year trial fitting and software fitting orthokeratology lenses. Methods: One hundred myopes who received vision correction with the use of orthokeratology lenses form July 2016 to September 2017 were included in this study. Subjects were assigned randomly into the two groups: the trial fitting group (group A) and the software fitting group (group B). For the right eye of each subject, measurements, such as uncorrected visual acuity (UCVA, logarithm of minimal angle of resolution), refractive error, corneal topography, ocular health status, and the fitting situation, were obtained at baseline, 1 week, 1 month, 3 months, 6 months, and 12 months after lens wear. Axial length and corneal endothelium cells (CECs) were also measured at baseline and 12 months after wearing the lens. Results: Compared with the baseline, the spherical equivalent refraction, UCVA, and central corneal curvature changed significantly after orthokeratology (OK) lens wear (all P<0.05). Between groups A and B, the parameters aforementioned were insignificant at each time point (all P>0.05). Axial length and CECs showed no significant changes during the first year of OK treatment (all P>0.05). Rate of corneal staining between two groups revealed no difference during 1-year visit (P<0.05). Conclusion: Both the trial lens fitting and software fitting approaches were effective in temporarily reducing myopia, providing good UCVA and delaying the elongation of axial length for moderate and high myopic adolescents. Both the two approaches can be combined in OK lens fitting.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [21] ANTIHYPERTENSIVE EFFECT OF LOSARTAN - ONE-YEAR FOLLOW-UP STUDY
    Stojanov, V.
    Radivojevic, N.
    Jakovljevic, B.
    JOURNAL OF HYPERTENSION, 2017, 35 : E105 - E105
  • [22] THE LITHIUM INDEX IN A ONE-YEAR FOLLOW-UP
    KAMP, JS
    OEY, MS
    LEIJNSEYBEMA, HJ
    MOST, EVD
    VANDORTSTAM, Y
    PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 1995, 19 (01): : 47 - 57
  • [23] A ONE-YEAR FOLLOW-UP OF FATIGUED PATIENTS
    VALDINI, AF
    STEINHARDT, S
    VALICENTI, J
    JAFFE, A
    JOURNAL OF FAMILY PRACTICE, 1988, 26 (01): : 33 - 38
  • [24] ONE-YEAR FOLLOW-UP OF EPIKERATOPHAKIA FOR KERATOCONUS
    UUSITALO, RJ
    LEHTOSALO, J
    KLYCE, SD
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1989, 227 (05) : 401 - 407
  • [25] Laparoscopic cryomyolysis: One-year follow-up
    Zupi, E
    Piredda, A
    Marconi, D
    Townsend, D
    Exacoustos, C
    Szabolcs, B
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 58S - 58S
  • [26] REFERRAL FAILURES - ONE-YEAR FOLLOW-UP
    CHAMEIDES, WA
    YAMAMOTO, J
    AMERICAN JOURNAL OF PSYCHIATRY, 1973, 130 (10): : 1157 - 1158
  • [27] Evaluation study on prophylaxis: A randomised Italian trial (ESPRIT). One-year follow-up report
    Gringeri, A
    THROMBOSIS RESEARCH, 1998, 91 (03) : S8 - S8
  • [28] ONE-YEAR FOLLOW-UP OF CYSTOID MACULAR EDEMA FOLLOWING INTRAOCULAR LENS IMPLANTATION
    WINSLOW, RL
    TAYLOR, BC
    HARRIS, WS
    OPHTHALMOLOGY, 1978, 85 (02) : 190 - 196
  • [29] One-year follow-up of toric intraocular lens implantation in forme fruste keratoconus
    Navas, Alejandro
    Suarez, Raul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (11): : 2024 - 2027
  • [30] One-year follow-up of a TRASER clinical trial for the treatment of nasal telangiectasias
    Geddes-Bruce, Elizabeth
    Hamill, Selina S.
    Zachary, Christopher B.
    Friedman, Paul M.
    LASERS IN SURGERY AND MEDICINE, 2018, 50 (01) : 61 - 63