Efficacy of Trial Fitting and Software Fitting for Orthokeratology Lens: One-Year Follow-Up Study

被引:7
|
作者
Lu, Daqian [1 ,2 ]
Gu, Tianpu [1 ,2 ]
Lin, Weiping [1 ,2 ]
Li, Na [1 ,2 ]
Gong, Boteng [1 ,2 ]
Wei, Ruihua [1 ,2 ]
机构
[1] Tianjin Med Univ, Eye Hosp, Tianjin, Peoples R China
[2] Tianjin Med Univ, Tianjin, Peoples R China
来源
关键词
Orthokeratology lens; Trial fitting and software fitting; Efficacy; MYOPIA; CHILDREN; PROGRESSION; ANTERIOR;
D O I
10.1097/ICL.0000000000000539
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To observe and compare the clinical efficacy of 1-year trial fitting and software fitting orthokeratology lenses. Methods: One hundred myopes who received vision correction with the use of orthokeratology lenses form July 2016 to September 2017 were included in this study. Subjects were assigned randomly into the two groups: the trial fitting group (group A) and the software fitting group (group B). For the right eye of each subject, measurements, such as uncorrected visual acuity (UCVA, logarithm of minimal angle of resolution), refractive error, corneal topography, ocular health status, and the fitting situation, were obtained at baseline, 1 week, 1 month, 3 months, 6 months, and 12 months after lens wear. Axial length and corneal endothelium cells (CECs) were also measured at baseline and 12 months after wearing the lens. Results: Compared with the baseline, the spherical equivalent refraction, UCVA, and central corneal curvature changed significantly after orthokeratology (OK) lens wear (all P<0.05). Between groups A and B, the parameters aforementioned were insignificant at each time point (all P>0.05). Axial length and CECs showed no significant changes during the first year of OK treatment (all P>0.05). Rate of corneal staining between two groups revealed no difference during 1-year visit (P<0.05). Conclusion: Both the trial lens fitting and software fitting approaches were effective in temporarily reducing myopia, providing good UCVA and delaying the elongation of axial length for moderate and high myopic adolescents. Both the two approaches can be combined in OK lens fitting.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [1] Lack of Efficacy for Atorvastatin Therapy in Aortic Stenosis: A One-Year Follow-Up Trial
    Sahebkar, Amirhossein
    Rakhshankhah, Amir
    Taghipour, Hamid Reza
    Dadjou, Yahya
    Pishgoo, Bahram
    Panahi, Yunes
    CARDIOVASCULAR THERAPEUTICS, 2012, 30 : 24 - 24
  • [2] A one-year follow-up analysis of the efficacy of implant overdentures
    Awad, MA
    Lund, JP
    Dufresne, E
    Feine, JS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 150 - 150
  • [3] ONE-YEAR FOLLOW-UP FROM THE GUSTO I TRIAL
    CALIFF, RM
    TOPOL, EJ
    VANDERWERF, F
    LEE, KL
    WOODLIEF, L
    CIRCULATION, 1994, 90 (04) : 325 - 325
  • [4] Implantation of a diffractive trifocal intraocular lens: One-year follow-up
    Mojzis, Peter
    Majerova, Katarina
    Hrckova, Lucia
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1623 - 1630
  • [5] Alexithymia and depression - a one-year follow-up study
    Saarijarvi, SP
    Salminen, JK
    Toikka, T
    EUROPEAN PSYCHIATRY, 2002, 17 : 128S - 128S
  • [6] UVULOPALATOPHARYNGOPLASTY - ONE-YEAR FOLLOW-UP
    CONWAY, W
    FUJITA, S
    ZORICK, F
    SICKLESTEEL, J
    ROEHRS, T
    WITTIG, R
    ROTH, T
    CHEST, 1985, 88 (03) : 385 - 387
  • [7] FOLLOW-UP - ONE-YEAR LATER
    MCLAUGHLIN, LR
    WILSON LIBRARY BULLETIN, 1977, 51 (09) : 725 - 726
  • [8] Nucleoplasty: one-year follow-up
    Antochi, F. A.
    Romanitan, M. O.
    Roceanu, A.
    Bajenaru, O.
    Dorobat, B.
    Nechifor, R.
    JOURNAL OF NEUROLOGY, 2008, 255 : 138 - 138
  • [9] Evaluation of Orthokeratology Lens Fitting Assisted by Sagittal Height Simulation Software
    Yi, Zhen
    Jing, Shen
    Wang Wenhua
    Qian, Li
    Wang Ningli
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (02): : 78 - 82
  • [10] Efficacy of Levonorgestrel Releasing Intrauterine System in Menorrhagia: A One-Year Follow-up Study
    Haberal, Ali
    Kayikcioglu, Fulya
    Gunes, Muzeyyen
    Ozdegirmanci, Ozlem
    Kaplan, Metin
    JOURNAL OF THE TURKISH-GERMAN GYNECOLOGICAL ASSOCIATION, 2005, 6 (02) : 130 - 133