Influence of Femoral Implant Alignment in Uncemented Total Hip Replacement Arthroplasty: Varus Insertion and Stress Shielding

被引:0
|
作者
Kawaji, Hidemi [1 ]
Uematsu, Takuya [1 ]
Oba, Ryosuke [1 ]
Hoshikawa, Naoya [1 ]
Watanabe, Hiroshi [1 ]
Takai, Shinro [1 ]
机构
[1] Nippon Med Sch, Dept Orthopaed Surg, Tokyo, Japan
关键词
uncemented total hip replacement arthroplasty; varus insertion; stress shielding; FOLLOW-UP; BONE LOSS; STEM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. Materials and Methods: The study participants included 89 patients who underwent uncemented THR for 106 joints and were followed-up for > 3 years. From clinical records, we retrieved Japanese Orthopaedic Association (JOA) pain scores and the range of motion (ROM) of flexion and abduction both preoperatively and at the final follow-up. The presence of varus insertion of the femoral implant and stress shielding were also retrospectively reviewed from X-rays. We defined varus insertion of the femoral implant as the axis of the femoral implant that was inclined to the femoral shaft by 2 or more. Stress shielding was judged in accordance with Engh's classification system. Results: Of the 106 joints, varus insertion was observed in 40 (37.3%) (the varus group) but not in 66 (62.3%) (the non-varus group). The JOA pain score significantly improved in both groups; however, there were no significant differences between the groups. Although ROM improved in both groups, there were no significant differences between the groups. The appearance rate of stress shielding of >= third degree in the varus group was significantly greater than that in the non-varus group. Conclusion: These results revealed that varus insertion of femoral implants had no influence on short to mid-term clinical outcomes because the pain score and ROM significantly improved in both the varus and non-varus groups. However, high rates of severe stress shielding appeared with varus insertion of femoral implants, suggesting an influence on long-term clinical outcomes.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [31] Implant survival in uncemented total hip arthroplasty for displaced intracapsular femoral neck fractures: outcomes of 115 patients in a single center
    Melissa N. Dogger
    Bas L. Fransen
    Inger N. Sierevelt
    Peter A. Nolte
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 885 - 893
  • [32] Femoral bowing affects varus femoral alignment but not patient satisfaction in mechanically aligned total knee arthroplasty
    Naoki Umatani
    Shinichi Kuriyama
    Kohei Nishitani
    Shinichiro Nakamura
    Hiromu Ito
    Shuichi Matsuda
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 89 - 96
  • [33] Implant survival in uncemented total hip arthroplasty for displaced intracapsular femoral neck fractures: outcomes of 115 patients in a single center
    Dogger, Melissa N.
    Fransen, Bas L.
    Sierevelt, Inger N.
    Nolte, Peter A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (05): : 885 - 893
  • [34] Uncemented total hip arthroplasty in young adults with osteonecrosis of the femoral head: A comparative study
    Mont, Michael A.
    Seyler, Thorsten M.
    Plate, Johannes F.
    Delanois, Ronald E.
    Parvizi, Javad
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 104 - 109
  • [35] Bulk femoral-head autografting in uncemented total hip arthroplasty for acetabular dysplasia
    Shetty, AA
    Sharma, P
    Singh, S
    Tindall, A
    Kumar, SV
    Rand, C
    JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 706 - 713
  • [36] Influence of Femoral Stem Geometry on Total Hip Replacement: A Comparison of Clinical Outcomes of a Straight and an Anatomical Uncemented Stem
    Berdini, Massimo
    Procaccini, Roberto
    Zanoli, Gabriele Franco
    Faini, Andrea
    Verdenelli, Aldo
    Gigante, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [37] Alumina femoral head fracture in uncemented total hip arthroplasty with a ceramic sandwich cup
    Hwang, Deuk-Soo
    Kim, Young-Mo
    Lee, Chang-Hwan
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 468 - 471
  • [38] A COLLARLESS COBALT-CHROME FEMORAL COMPONENT IN UNCEMENTED TOTAL HIP-ARTHROPLASTY
    PELLEGRINI, VD
    HUGHES, SS
    EVARTS, CM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06): : 814 - 821
  • [39] OSTEOPOROSIS AND THE INCIDENCE OF PERIPROSTHETIC FEMORAL FRACTURES AFTER UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY
    Ene, R.
    Nica, M.
    Panti, Z.
    Ene, P.
    Cirstoiu, M.
    Cirstoiu, C.
    OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S449 - S449
  • [40] Peroperative fractures in uncemented total hip arthroplasty: results with a single design of stem implant
    Ricardo Fernandez-Fernandez
    Elena García-Elias
    Enrique Gil-Garay
    International Orthopaedics, 2008, 32 (3) : 315 - 315