Validity of the Intelligent Device for Energy Expenditure and Activity Accelerometry System for Quantitative Gait Analysis in Patients With Hip Osteoarthritis

被引:16
|
作者
Item-Glatthorn, Julia F. [1 ]
Casartelli, Nicola C. [1 ]
Petrich-Munzinger, Jeannette [2 ]
Munzinger, Urs K. [2 ]
Maffiuletti, Nicola A. [1 ]
机构
[1] Schulthess Clin, Neuromuscular Res Lab, CH-8008 Zurich, Switzerland
[2] Bethanien Clin, Lower Extrem Dept, Zurich, Switzerland
来源
关键词
Osteoarthritis; hip; Rehabilitation; Walking; GAITRITE(R) WALKWAY SYSTEM; STEP PARAMETERS; RELIABILITY; QUANTIFICATION; IDEEA; WALKING;
D O I
10.1016/j.apmr.2012.06.018
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Item-Glatthom JF, Casartelli NC, Petrich-Munzinger J, Munzinger UK, Maffiuletti NA. Validity of the Intelligent Device for Energy Expenditure and Activity accelerometry system for quantitative gait analysis in patients with hip osteoarthritis. Arch Phys Med Rehabil 2012;93:2090-3. Objective: To evaluate the concurrent validity of an accelerometry-based system (Intelligent Device for Energy Expenditure and Activity) with a criterion instrument (Gaitrite) for the evaluation of spatiotemporal gait variables in orthopedic patients. Design: Validity study. Setting: Research laboratory in an orthopedic hospital. Participants: Men with unilateral hip osteoarthritis (N=26; mean age +/- SD, 54 +/- 9y). Interventions: Not applicable. Main Outcome Measures: Patients were asked to walk at normal and fast velocities while gait cycle, swing, double support, step length, cadence, and speed were concomitantly recorded with the 2 instruments. Concurrent criterion-related validity was examined using intraclass correlation coefficients and Bland-Altman limits of agreement. Results: Intraclass correlation coefficients were acceptable for all gait parameters (range, .815.997), except step length (.783). Limits of agreement were low for gait cycle, swing, and cadence, though relatively high for double support, step length, and speed. A significant bias between the 2 measuring instruments was consistently observed. Conclusions: In patients with hip osteoarthritis, quantitative gait analysis with the IDEEA accelerometry system was satisfactory for the main temporal gait parameters, while double support, step length, and walking speed quantifications were invalid. The IDEEA system should be used with caution, and modifications of the system are recommended for improved use in clinical practice and research.
引用
下载
收藏
页码:2090 / 2093
页数:4
相关论文
共 50 条
  • [41] How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies
    O'Driscoll, Ruairi
    Turicchi, Jake
    Beaulieu, Kristine
    Scott, Sarah
    Matu, Jamie
    Deighton, Kevin
    Finlayson, Graham
    Stubbs, James
    BRITISH JOURNAL OF SPORTS MEDICINE, 2020, 54 (06) : 332 - +
  • [42] A 12-week exercise program for patients with hip osteoarthritis has no influence on gait parameters: A secondary analysis of a randomized controlled trial
    Krauss, Inga
    Hein, Tobias
    Steinhilber, Benjamin
    Janssen, Pia
    GAIT & POSTURE, 2020, 78 : 6 - 12
  • [43] One-Step Gait Pattern Analysis of Hip Osteoarthritis Patients Based on Dynamic Time Warping through Ground Reaction Force
    Ahn, Sohyun
    Choi, Wiha
    Jeong, Hieyong
    Oh, Sehoon
    Jung, Tae-Du
    APPLIED SCIENCES-BASEL, 2023, 13 (08):
  • [44] Hip Osteoarthritis Patients Demonstrated Marked Dynamic Changes and Variability in Pelvic Tilt, Obliquity, and Rotation: A Comparative, Gait-Analysis Study
    Sultan, Assem A.
    Cantrell, William A.
    Khlopas, Anton
    Udo-Inyang, Inyang, Jr.
    Chughtai, Morad
    Sodhi, Nipun
    Lamaj, Suela
    Starr, Roland
    Piuzzi, Nicolas S.
    Bhave, Anil
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2018, 32 : 948 - +
  • [45] Towards an Inertial Sensor-Based Wearable Feedback System for Patients after Total Hip Arthroplasty: Validity and Applicability for Gait Classification with Gait Kinematics-Based Features
    Teufl, Wolfgang
    Taetz, Bertram
    Miezal, Markus
    Lorenz, Michael
    Pietschmann, Juliane
    Joellenbeck, Thomas
    Froehlich, Michael
    Bleser, Gabriele
    SENSORS, 2019, 19 (22)
  • [46] Validity of motion analysis using the Kinect system to evaluate single leg stance in patients with hip disorders
    Asaeda, Makoto
    Kuwahara, Wataru
    Fujita, Naoto
    Yamasaki, Takuma
    Adachi, Nobuo
    GAIT & POSTURE, 2018, 62 : 458 - 462
  • [47] Validity of the ActiReg® system and a physical activity interview in assessing total energy expenditure in long-term survivors after total gastrectomy
    Copland, Lotta
    Liedman, Bengt
    Rothenberg, Elisabet
    Ellegard, Lars
    Hustvedt, Bo-Egil
    Bosaeus, Lngvar
    CLINICAL NUTRITION, 2008, 27 (06) : 842 - 848
  • [48] Low validity of the Sensewear Pro3 activity monitor compared to indirect calorimetry during simulated free living in patients with osteoarthritis of the hip
    Hermann, Andreas
    Ried-Larsen, Mathias
    Jensen, Andreas Kryger
    Holst, Rene
    Andersen, Lars Bo
    Overgaard, Soren
    Holsgaard-Larsen, Anders
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [49] Low validity of the Sensewear Pro3 activity monitor compared to indirect calorimetry during simulated free living in patients with osteoarthritis of the hip
    Andreas Hermann
    Mathias Ried-Larsen
    Andreas Kryger Jensen
    René Holst
    Lars Bo Andersen
    Søren Overgaard
    Anders Holsgaard-Larsen
    BMC Musculoskeletal Disorders, 15
  • [50] Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase?
    Mandigout, Stephane
    Lacroix, Justine
    Ferry, Beatrice
    Vuillerme, Nicolas
    Compagnat, Maxence
    Daviet, Jean-Christophe
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2017, 24 (18) : 2009 - 2016