Energy Consumption and Internal Distribution in Activated Sludge Wastewater Treatment Plants of Greece

被引:64
|
作者
Siatou, Alexandra [1 ]
Manali, Anthoula [1 ]
Gikas, Petros [1 ]
机构
[1] Tech Univ Crete, Sch Environm Engn, Design Environm Proc Lab, Khania 73100, Greece
关键词
WWTP; energy consumption; energy assessment; aeration tank; activated sludge; EFFICIENCY;
D O I
10.3390/w12041204
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The high-energy consumption of wastewater treatment plants (WWTPs) is a crucial issue for municipalities worldwide. Most WWTPs in Greece operate as extended aeration plants, which results in high operational costs due to high energy needs. The present study investigated the energy requirements of 17 activated sludge WWTPs in Greece, serving between 1100-56,000 inhabitants (population equivalent, PE), with average daily incoming flowrates between 300-27,300 m(3)/d. The daily wastewater production per inhabitant was found to lie between 0.052 m(3)/PE.d and 0.426 m(3)/PE.d, with average volume of 0.217 +/- 0.114 m(3)/PE.d. The electric energy consumption per volume unit (E-Q (kWh/m(3))) was between 0.128-2.280 kWh/m(3) (average 0.903 +/- 0.509 kWh/m(3)) following a near logarithmic descending correlation with the average incoming flowrate (Q(av)) (E-Q = 0.294/nQ(av) + 3.1891; R-2 = 0.5337). A similar relationship was found between the daily electric energy requirements for wastewater treatment per inhabitant (E-PE (kWh/PE.d)) as a function of PE, which varied from 0.041-0.407 kWh/PE.d (average 0.167 +/- 0.101 kWh/PE.d)) (E-PE = 0.073ln(PE) + 0.8425; R-2 = 0.6989). Similarly, the daily energy cost per inhabitant (E-(sic)/PE ((sic)/PE.d)) as a function of PE and the electric energy cost per wastewater volume unit (E-(sic)/V ((sic)/m(3))) as a function of average daily flow (Q(av)) were found to follow near logarithmic trends (E-(sic)/PE = 0.013ln(PE) + 0.1473; R-2 = 0.6388, and E-(sic)/V = 0.052lnQ(av) + 0.5151; R-2 = 0.6359), respectively), with E-(sic)/PE varying between 0.005-0.073 (sic)/PE.d (average 0.024 +/- 0.019 (sic)/PE.d) and E-(sic)/V between 0.012-0.291 (sic)/m(3) (average 0.111 +/- 0.077 (sic)/m(3)). Finally, it was calculated that, in an average WWTP, the aeration process is the main energy sink, consuming about 67.2% of the total electric energy supply to the plant. The large variation of energy requirements per inlet volume unit and per inhabitant served, indicate that there is large ground for improving the performance of the WWTPs, with respect to energy consumption.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Oxygen Transfer in Two-Stage Activated Sludge Wastewater Treatment Plants
    Schwarz, Maximilian
    Behnisch, Justus
    Trippel, Jana
    Engelhart, Markus
    Wagner, Martin
    WATER, 2021, 13 (14)
  • [32] Assessment of energy consumption of municipal wastewater treatment plants in China
    He, Yan
    Zhu, Yishuang
    Chen, Jinghan
    Huang, Minsheng
    Wang, Pan
    Wang, Guohua
    Zou, Weiguo
    Zhou, Gongming
    JOURNAL OF CLEANER PRODUCTION, 2019, 228 : 399 - 404
  • [33] A reference model for evaluating control strategies in activated sludge wastewater treatment plants
    Sotomayor, O.A.Z.
    Park, S.W.
    Garcia, C.
    Revue des Sciences de l'Eau, 2002, 15 (02): : 543 - 556
  • [34] Benchmarking energy consumption in municipal wastewater treatment plants in Japan
    Mizuta, Kentaro
    Shimada, Masao
    WATER SCIENCE AND TECHNOLOGY, 2010, 62 (10) : 2256 - 2262
  • [35] Microbial Community Structure of Activated Sludge in Treatment Plants with Different Wastewater Compositions
    Shchegolkova, Nataliya M.
    Krasnov, George S.
    Belova, Anastasia A.
    Dmitriev, Alexey A.
    Kharitonov, Sergey L.
    Klimina, Kseniya M.
    Melnikova, Nataliya V.
    Kudryavtseva, Anna V.
    FRONTIERS IN MICROBIOLOGY, 2016, 7
  • [36] Diversity of Activated Sludge Microbial Community Structure in Different Wastewater Treatment Plants
    Feng Ziyan Yang
    Qing Guo
    Jiaying Wang
    Yilong Zhao
    Xinfeng Wang
    Yanli Zhu
    Junfeng Mao
    Zhongxian Wu
    Hongwei Song
    Wei Hu
    Biao Peng
    Biology Bulletin, 2023, 50 : 329 - 337
  • [37] Activated Sludge Microbial Community and Treatment Performance of Wastewater Treatment Plants in Industrial and Municipal Zones
    Yang, Yongkui
    Wang, Longfei
    Xiang, Feng
    Zhao, Lin
    Qiao, Zhi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (02)
  • [38] Characterization of wastewater and activated sludge from European municipal wastewater treatment plants using the NUR test
    Naidoo, V
    Urbain, V
    Buckley, CA
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (01) : 303 - 310
  • [39] A Practical Methodology for Forecasting the Impact of Changes in Influent Loads and Discharge Consents on Average Energy Consumption and Sludge Production by Activated Sludge Wastewater Treatment
    Silva, Catarina
    Rosa, Maria Joao
    SUSTAINABILITY, 2021, 13 (21)
  • [40] Distribution of phosphorus, copper and zinc in activated sludge treatment process of swine wastewater
    Suzuki, Kazuyoshi
    Waki, Miyoko
    Yasuda, Tomoko
    Fukumoto, Yasuyuki
    Kuroda, Kazutaka
    Sakai, Takahiro
    Suzuki, Naoto
    Suzuki, Ryoji
    Matsuba, Kenji
    BIORESOURCE TECHNOLOGY, 2010, 101 (23) : 9399 - 9404