A Flow Cytometry-Based Assay for High-Throughput Detection and Quantification of Neutrophil Extracellular Traps in Mixed Cell Populations

被引:38
|
作者
Zharkova, Olga [1 ]
Tay, Sen Hee [2 ,3 ,4 ,5 ]
Lee, Hui Yin [5 ]
Shubhita, Tripathi [2 ,5 ]
Ong, Wei Yee [6 ]
Lateef, Aisha [3 ,4 ]
MacAry, Paul Anthony [2 ]
Lim, Lina Hsiu Kim [1 ]
Connolly, John Edward [6 ]
Fairhurst, Anna-Marie [2 ,5 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Physiol, Singapore, Singapore
[2] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Microbiol & Immunol, Singapore, Singapore
[3] Natl Univ Hlth Syst, Dept Med, Singapore, Singapore
[4] Natl Univ Hlth Syst, Natl Univ Hosp, Dept Med, Div Rheumatol, Singapore, Singapore
[5] ASTAR, Singapore Immunol Network, 8A Biomed Grove,04-06 Immunos, Singapore 138648, Singapore
[6] ASTAR, Inst Mol & Cellular Biol, Singapore, Singapore
关键词
neutophils; extracellular traps; flow cytometry; MITOCHONDRIAL-DNA; NET FORMATION; IN-VITRO; ACTIVATION; MYELOPEROXIDASE; LOCALIZATION; LIMITATIONS; DISEASE; BINDING; NETOSIS;
D O I
10.1002/cyto.a.23672
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Neutrophil extracellular traps (NETs) are web-like structures composed of decondensed chromatin and antimicrobial proteins that are released into the extracellular space during microbial infections. This active cell death program is known as NETosis. To date, florescence microscopy is the widely accepted method for visualization and quantification of NETs. However, this method is subjective, time consuming and yields low numbers of analyzed polymorphonuclear cells (PMNs) per sample. Increasing interest has emerged on the identification of NETs using flow cytometry techniques. However, flow cytometry analysis of NETs requires particular precautions for sample preparation to obtain reproducible data. Herein, we describe a flow cytometry-based assay for high-throughput detection and quantification of NETosis in mixed cell populations. We used fluorescent-labeled antibodies against cell markers on PMNs together with a combination of nucleic acid stains to measure NETosis in whole blood (WB) and purified PMNs. Using plasma membrane-impermeable DNA-binding dye, SYTOX Orange (SO), we found that cell-appendant DNA of NETting PMNs were positive for SO and DAPI. The combination of optimally diluted antibody and nucleic acid dyes required no washing and yielded low background fluorescence. Significant correlations were found for NETosis from WB and purified PMNs. We then validated the assay by comparing with time-lapse live cell fluorescence microscopy and determined very good intraassay and interassay variances. The assay was then applied to a disease associated with NETosis, systemic lupus erythematosus (SLE). We examined PMA-induced NETosis in peripheral PMNs from SLE patients and controls and in bone marrow PMNs from multiple murine models. In summary, this assay is observer-independent and allows for rapid assessment of a large number of PMNs per sample. Use of this assay does not require sophisticated microscopic equipment like imaging flow cytometers and may be a starting point to analyze extracellular trap formation from immune cells other than PMNs. (c) 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.
引用
收藏
页码:268 / 278
页数:11
相关论文
共 50 条
  • [31] Development of a high-throughput γ-H2AX assay based on imaging flow cytometry
    Younghyun Lee
    Qi Wang
    Igor Shuryak
    David J. Brenner
    Helen C. Turner
    Radiation Oncology, 14
  • [32] Development of a high-throughput γ-H2AX assay based on imaging flow cytometry
    Lee, Younghyun
    Wang, Qi
    Shuryak, Igor
    Brenner, David J.
    Turner, Helen C.
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [33] A Flow Cytometry-Based Cytotoxicity Assay for the Assessment of Human NK Cell Activity
    Kandarian, Fadi
    Sunga, Gemalene M.
    Arango-Saenz, Diana
    Rossetti, Maura
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (126):
  • [34] Flow cytometry-based ex vivo murine NK cell cytotoxicity assay
    Wong, Pamela
    Wagner, Julia A.
    Berrien-Elliott, Melissa M.
    Schappe, Timothy
    Fehniger, Todd A.
    STAR PROTOCOLS, 2021, 2 (01):
  • [35] A high-throughput unscheduled DNA synthesis (UDS) assay using flow cytometry
    Kirk, M.
    Reeder, M.
    Ripper, T.
    Fischl, M.
    Cerven, D.
    DeGeorge, G.
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2005, 41 : 61A - 61A
  • [36] A novel flow cytometry-based assay for the quantification of Staphylococcus aureus adhesion to and invasion of eukaryotic cells
    Trouillet, Sophie
    Rasigade, Jean-Philippe
    Lhoste, Yannick
    Ferry, Tristan
    Vandenesch, Francois
    Etienne, Jerome
    Laurent, Frederic
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 86 (02) : 145 - 149
  • [37] A High-Throughput System for Quantification of in Vitro Neutrophil Extracellular Trap Formation with Fluorescence Immunocytochemistry
    Kraaij, Tineke
    Kamerling, Sylvia
    Rabelink, Ton
    Toes, Rene E. M.
    van Kooten, Cees
    Teng, Onno
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [38] Development of a Fixable Flow Cytometry-Based Natural Killer Cell Cytotoxicity Assay
    Laporte, J.
    Verhoeven, R.
    Ruddock, W.
    INTERNATIONAL JOURNAL OF TOXICOLOGY, 2018, 37 (01) : 71 - 71
  • [39] A high-throughput method for detection of DNA in chloroplasts using flow cytometry
    Rowan, Beth A.
    Oldenburg, Delene J.
    Bendich, Arnold J.
    PLANT METHODS, 2007, 3 (1)
  • [40] A high-throughput method for detection of DNA in chloroplasts using flow cytometry
    Beth A Rowan
    Delene J Oldenburg
    Arnold J Bendich
    Plant Methods, 3