Study on the performance of an open-loop passive containment cooling system

被引:7
|
作者
Bai, Jinhua [1 ,2 ]
Zhao, Bo [2 ]
Wang, Jianjun [1 ]
机构
[1] Harbin Engn Univ, Coll Nucl Sci & Technol, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin, Heilongjiang, Peoples R China
[2] China Nucl Power Engn Co Ltd, Beijing, Peoples R China
关键词
Containment; passive cooling system; open loop; single phase; two-phase flow; FLASHING-INDUCED INSTABILITIES; BOILING WATER-REACTORS; NATURAL-CIRCULATION; START-UP; SIMULATION; STABILITY; DESIGN; PLANT; CODE;
D O I
10.1080/00223131.2017.1386133
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The containment is an ultimate and important barrier to keep the radioactivity from release. The integrity of the containment is crucial to control the consequences of either loss of coolant accident or main steam line break accident. A passive containment cooling system concept designed to remove the heat by natural circulation means is proposed, which is composed of a series of heat exchangers, long connecting pipes with relative large diameter, valves, and a water tank. The performance of the system is numerically simulated and the self-developed codes are validated by the experimental data. The influences of several key parameters are investigated on the performance of the system from different aspects. The results confirm that four distinct operating stages could be experienced as follows: startup stage, single-phase quasi-steady stage, flashing speed up transient stage, and flashing dominated quasi-steady operating stage. Furthermore, the mechanisms of the ways through which the parameters influence the behaviors of the proposed system are thus analyzed. Moreover, the feasibility of the system is also commented on the basis of the numerical results.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [21] Experimental investigation of two-phase natural circulation loop as passive containment cooling system
    Lim, Sun Taek
    Kim, Koung Moon
    Kim, Haeseong
    Jerng, Dong-Wook
    Ahn, Ho Seon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 3918 - 3929
  • [22] Performance Limits for Open-Loop Fractional Dividers
    Tulisi, Stefano
    Kennedy, Michael Peter
    2017 28TH IRISH SIGNALS AND SYSTEMS CONFERENCE (ISSC), 2017,
  • [23] An Experimental Study on the Cooling Characteristics of Passive Containment Cooling Systems
    Kawakubo, Masahiro
    Aritomi, Masanori
    Kikura, Hiroshige
    Komeno, Toshihiro
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2009, 46 (04) : 339 - 345
  • [24] An Experimental Study on the Cooling Characteristics of passive containment cooling systems
    Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1, N1-13, O-okayama, Meguro-ku, Tokyo 152-8550, Japan
    不详
    J Nucl Sci Technol, 4 (339-345):
  • [25] A NEW OPEN-LOOP INSULIN DELIVERY SYSTEM
    SIPOSS, GG
    DAVIDSON, MB
    MEDICAL INSTRUMENTATION, 1981, 15 (05): : 338 - 340
  • [26] HELMET MOUNTED SIGHTS - CLOSING LOOP WITH AN OPEN-LOOP SYSTEM
    COULOMBE, SA
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1977, 13 (04) : 459 - 459
  • [27] Theoretical modelling and system response of a passive containment cooling system
    Maheshwari, NK
    Saha, D
    Sinha, RK
    Aritomi, M
    KERNTECHNIK, 2003, 68 (1-2) : 41 - 47
  • [28] OPEN-LOOP DISTRIBUTION-SYSTEM DESIGN
    GLAMOCANIN, V
    FILIPOVIC, V
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (04) : 1900 - 1906
  • [29] OPEN-LOOP NONITERATIVE COORDINATION IN A MULTILEVEL SYSTEM
    STOILOVA, KP
    STOILOV, TA
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 1995, 26 (10) : 1887 - 1905
  • [30] Assignment of infinite structure to an open-loop system
    Amparan, A
    Marcaida, S
    Zaballa, I
    LINEAR ALGEBRA AND ITS APPLICATIONS, 2004, 379 : 249 - 266