Soft x-ray measurement of the toroidal pinch experiment RX reversed field pinch plasma using transition edge sensor calorimeter

被引:5
|
作者
Shinozaki, K
Hoshino, A
Ishisaki, Y
Morita, U
Ohashi, T
Mihara, T
Mitsuda, K
Tanaka, K
Yagi, Y
Koguchi, H
Hirano, Y
Sakakita, H
机构
[1] Tokyo Metropolitan Univ, Dept Phys, Hachioji, Tokyo 1920397, Japan
[2] Inst Phys & Chem Res, Wako, Saitama 3510198, Japan
[3] JAXA, ISAS, Sagamihara, Kanagawa 2298510, Japan
[4] SIINT Inc, Matsudo, Chiba 2702222, Japan
[5] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 04期
基金
日本学术振兴会;
关键词
D O I
10.1063/1.2173029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A superconductive transition edge sensor (TES) calorimeter is for the first time applied for the diagnostics of the reversed field pinch plasma produced in the toroidal pinch experiment RX (TPE-RX), and the instrumental system is fully described. The first result from the soft x-ray spectroscopy in 0.2-3 keV with an energy resolution similar to 50 eV are also presented. The TES calorimeter is made of a thin bilayer film of titanium and gold with a transition temperature of 151 mK and its best energy resolution at our laboratory is 6.4 eV, while it was significantly degraded by about a factor of eight during the plasma operation. The TES microcalorimeter was installed in a portable adiabatic demagnetization refrigerator (ADR), which is originally designed for a rocket experiment. The detector box is carefully designed to shield the strong magnetic field produced by the ADR and TPE-RX. The ADR was directly connected to TPE-RX with a vacuum duct in the sideway configuration, and cooled down to 125 mK stabilized with an accuracy of 10 mu K rms using an improved proportional, integral, and derivative (PID) control method. Thin aluminized Toray Lumirror or Parylene-N films were used for the IR to UV blocking filters of the incident x-ray window to allow soft x-rays coming into the detector with good efficiency. TPE-RX was operated with the plasma current of I-p=220 kA, and the wave forms of the TES output for every plasma shot lasting similar to 80 ms were obtained with a digital oscilloscope. The wave forms were analyzed with the optimal filtering method, and x-ray signals were extracted. A total of 3472 counts of x-ray signals were detected for 210 plasma shots during the flat-top phase of t=35-70 ms. Combined with the data measured with a lithium drifted silicon detector in the 1.3-8 keV range, spectral features are investigated using a spectral fitting package XSPEC. The obtained spectrum is well explained by thermal plasma emission, although an impurity iron-L line emissions at variously ionized states are dominant around 0.7-1.2 keV. At least three different temperature components ranging T=350-900 eV are required to account for the spectral shape, while the average temperature is consistent with the ruby laser Thomson scattering measurement. (c) 2006 American Institute of Physics.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Design of capillary Z-pinch plasma for a soft X-ray laser
    Emami, M.
    LASER PHYSICS, 2007, 17 (01) : 18 - 21
  • [22] Soft X-ray lasing at 519.7 Å in a recombining Z-pinch plasma
    Eberl, E
    Wagner, T
    Jacoby, J
    Tauschwitz, A
    Hoffmann, DHH
    LASER AND PARTICLE BEAMS, 1997, 15 (04) : 589 - 595
  • [23] Measurement of plasma radiation fraction and impurity line spectra in the reversed field pinch device, TPE-RX
    Koguchi, H
    Yagi, Y
    Hirano, Y
    Shimada, T
    Sekine, S
    Sakakita, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (03): : 1159 - 1163
  • [24] THE MEASUREMENT OF SOFT X-RAYS FROM THE STP-3(M) REVERSED-FIELD PINCH PLASMA
    SHIINA, S
    SAITO, K
    ARIMOTO, H
    MATSUOKA, A
    YAMADA, S
    MASAMUNE, S
    NAGATA, A
    SATO, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1987, 56 (04) : 1282 - 1285
  • [25] Properties of the edge plasma in the rebuilt Extrap-T2R reversed field pinch experiment
    Vianello, N
    Spolaore, M
    Serianni, G
    Bergsåker, H
    Antoni, V
    Drake, JR
    PLASMA PHYSICS AND CONTROLLED FUSION, 2002, 44 (12) : 2513 - 2523
  • [26] High-speed superconducting x-ray calorimeter using a transition edge sensor
    Morooka, T
    Tanaka, K
    Nagata, A
    Nakayama, S
    Chinone, K
    Futamoto, K
    Fujimoto, R
    Mitsuda, K
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2002, 15 (01): : 133 - 135
  • [27] Enhancement of soft X-ray emission from a pinch plasma using a rotating plasma for pre-ionization
    Ohzu, A
    OPTICS AND LASER TECHNOLOGY, 2000, 32 (05): : 379 - 383
  • [28] Quantitative measurement of x-ray images with a gated microchannel plate system in a z-pinch plasma experiment
    Shan, B
    Yanagidaira, T
    Shimoda, K
    Hirano, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1688 - 1693
  • [29] Investigation of plasma edge turbulence using a gas-puff imaging system in the reversed-field pinch device TPE-RX
    Cavazzana, R.
    Serianni, G.
    Scarin, P.
    Agostini, M.
    Vianello, N.
    Yagi, Y.
    Koguchi, H.
    Kiyama, S.
    Sakakita, H.
    Hirano, Y.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2007, 49 (02) : 129 - 143