A novel technique for closed-chamber iridodialysis repair

被引:2
|
作者
Huang, Jen-Yu [1 ]
Liu, Yu-Ling [2 ]
Huang, Ya-Chi [2 ]
Lin, Chang-Ping [2 ]
机构
[1] Taichung Vet Gen Hosp, Dept Ophthalmol, Taichung, Taiwan
[2] Changhua Christian Hosp, Dept Ophthalmol, Changhua, Taiwan
关键词
Closed-chamber; iridodialysis; repair;
D O I
10.4103/tjo.tjo_26_19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: We introduce a novel technique for closed chamber iridodialysis repair. MATERIALS AND METHODS: We use a 2.8-mm paracentesis knife to penetrate into the anterior chamber and create interrupted incisions in the sclera. The wounds are 1.5 mm distant from the limbus, at consistent 2.8-mm intervals along the dialysis area. After injecting viscocohesive ophthalmic viscosurgical device through a side port to relieve the synechia and to push the iris toward the incisions, the iris is then grasped by Kelman forceps through the sclera, dragged carefully, and incarcerated. After adjusting the tension of the iris according to the pupil shape, the sclera and the incarcerated iris tissue were sutured together with 10-0 nylon. RESULTS: The technique was effective in six patients with traumatic iridodialysis. CONCLUSION: Our surgical technique repairs the iris, restores the shape of pupil, as well as avoids creating a large incision in the limbus in patients suffering from iridodialysis.
引用
收藏
页码:208 / 211
页数:4
相关论文
共 50 条
  • [1] A CLOSED-CHAMBER TECHNIQUE FOR REPAIR OF IRIDODIALYSIS
    ZEITER, JH
    SHIN, DH
    SHI, DX
    OPHTHALMIC SURGERY AND LASERS, 1993, 24 (07): : 476 - 480
  • [2] THE CLOSED-CHAMBER SLIPPING SUTURE TECHNIQUE FOR IRIS REPAIR
    SIEPSER, SB
    ANNALS OF OPHTHALMOLOGY, 1994, 26 (03): : 71 - 72
  • [3] REPAIR OF SECTOR IRIS COLOBOMA - CLOSED-CHAMBER TECHNIQUE
    SHIN, DH
    ARCHIVES OF OPHTHALMOLOGY, 1982, 100 (03) : 460 - 461
  • [4] Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study
    Wan, Wenjuan
    Shi, Lei
    Li, Can
    BMC OPHTHALMOLOGY, 2018, 18
  • [5] Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study
    Wenjuan Wan
    Lei Shi
    Can Li
    BMC Ophthalmology, 18
  • [6] A simple closed chamber technique for repair of traumatic iridodialysis in phakic eyes
    Erakgun, T
    Kaskaloglu, M
    Kayikcioglu, O
    OPHTHALMIC SURGERY AND LASERS, 2001, 32 (01): : 83 - 85
  • [7] Closed chamber iridodialysis repair using a needle with a distal hole
    Bardak, Y
    Ozerturk, Y
    Durmus, M
    Mensiz, E
    Aytuluner, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02): : 173 - 176
  • [8] Closed chamber iridodialysis repair using a needle with a distal hole
    Bhende, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1267 - 1268
  • [9] Closed chamber iridodialysis repair using a needle with a distal hole -: Reply
    Bardak, Y
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1268 - 1268
  • [10] STUDIES ON CLOSED-CHAMBER FIRES
    CHOW, WK
    JOURNAL OF FIRE SCIENCES, 1995, 13 (02) : 89 - 103