Accuracy of imageless stem navigation during simulated total hip arthroplasty

被引:8
|
作者
Renkawitz, Tobias [1 ]
Sendtner, Ernst [1 ]
Grifka, Joachim [1 ]
Kalteis, Thomas [1 ]
机构
[1] Univ Regensburg, Med Ctr, Asklepios Klinikum, Dept Orthoped Surg, Bad Abbach, Germany
关键词
D O I
10.1080/17453670810016858
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose New computer-assisted measurement algorithms have been established to support the surgeon during total joint replacement intraoperatively. We asked whether the assessment of leg length and offset measured with an imageless navigation system is reliable during simulated total hip arthroplasty in a sawbone model test bench. Methods and results We found no statistically significant difference between change in leg length and offset measured on a millimeter scale connected to the test bench and that obtained with the calculation algorithm of the imageless navigation system. Interpretation Measurement of leg length and offset with an imageless navigation system is reliable during simulated total hip arthroplasty. The leg length situation algorithm offers the advantage of measuring leg length and offset by determination of the change in position of the femur relative to the pelvic coordinate system without the need to calculate the center of rotation of the hip joint. Further studies should address the accuracy of this imageless stem navigation method in an anatomical and clinical setting.
引用
收藏
页码:785 / 788
页数:4
相关论文
共 50 条
  • [31] The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
    Florian Schmidutz
    Arnd Steinbrück
    Lorenz Wanke-Jellinek
    Matthias Pietschmann
    Volkmar Jansson
    Andreas Fottner
    International Orthopaedics, 2012, 36 : 1767 - 1772
  • [32] The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
    Schmidutz, Florian
    Steinbrueck, Arnd
    Wanke-Jellinek, Lorenz
    Pietschmann, Matthias
    Jansson, Volkmar
    Fottner, Andreas
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1767 - 1772
  • [33] Evaluation of Component Positioning in Primary Total Hip Arthroplasty Using an Imageless Navigation Device Compared With Traditional Methods
    Najarian, Brian C.
    Kilgore, John E.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 15 - 21
  • [34] The use of imageless navigation to quantify cutting error in total knee arthroplasty
    Ran Schwarzkopf
    Morteza Meftah
    Scott E. Marwin
    Michelle A. Zabat
    Jeffrey M. Muir
    Iain R. Lamb
    Knee Surgery & Related Research, 33
  • [35] The use of imageless navigation to quantify cutting error in total knee arthroplasty
    Schwarzkopf, Ran
    Meftah, Morteza
    Marwin, Scott E.
    Zabat, Michelle A.
    Muir, Jeffrey M.
    Lamb, Iain R.
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [36] Imageless optical navigation system is clinically valid for total knee arthroplasty
    Winberg, Taylor B.
    Wang, Sheila
    Howard, James L.
    COMPUTER ASSISTED SURGERY, 2025, 30 (01)
  • [37] Handheld imageless robotic total knee arthroplasty improves accuracy and early clinical outcomes when compared with navigation
    Joshua Yeuk-Shun Tran
    Abbie Yan-Tung Tang
    Cham-Kit Wong
    Gloria Yan-Ting Lam
    Tsz-Lung Choi
    Rex Wang-Fung Mak
    Jonathan Patrick Ng
    Kevin Ki-Wai Ho
    Michael Tim-Yun Ong
    Patrick Shu-Hang Yung
    Arthroplasty, 7 (1)
  • [38] Portable imageless navigation system and surgeon’s estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position
    Ryohei Takada
    Tetsuya Jinno
    Kazumasa Miyatake
    Masanobu Hirao
    Toshitaka Yoshii
    Atsushi Okawa
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 707 - 712
  • [39] Does difference in stem design affect accuracy of stem alignment in total hip arthroplasty with a CT-based navigation system?
    Ichiro Nakahara
    Takayuki Kyo
    Yasuo Kuroda
    Hidenobu Miki
    Journal of Artificial Organs, 2021, 24 : 74 - 81
  • [40] Does difference in stem design affect accuracy of stem alignment in total hip arthroplasty with a CT-based navigation system?
    Nakahara, Ichiro
    Kyo, Takayuki
    Kuroda, Yasuo
    Miki, Hidenobu
    JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (01) : 74 - 81