Accuracy of imageless stem navigation during simulated total hip arthroplasty

被引:8
|
作者
Renkawitz, Tobias [1 ]
Sendtner, Ernst [1 ]
Grifka, Joachim [1 ]
Kalteis, Thomas [1 ]
机构
[1] Univ Regensburg, Med Ctr, Asklepios Klinikum, Dept Orthoped Surg, Bad Abbach, Germany
关键词
D O I
10.1080/17453670810016858
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose New computer-assisted measurement algorithms have been established to support the surgeon during total joint replacement intraoperatively. We asked whether the assessment of leg length and offset measured with an imageless navigation system is reliable during simulated total hip arthroplasty in a sawbone model test bench. Methods and results We found no statistically significant difference between change in leg length and offset measured on a millimeter scale connected to the test bench and that obtained with the calculation algorithm of the imageless navigation system. Interpretation Measurement of leg length and offset with an imageless navigation system is reliable during simulated total hip arthroplasty. The leg length situation algorithm offers the advantage of measuring leg length and offset by determination of the change in position of the femur relative to the pelvic coordinate system without the need to calculate the center of rotation of the hip joint. Further studies should address the accuracy of this imageless stem navigation method in an anatomical and clinical setting.
引用
收藏
页码:785 / 788
页数:4
相关论文
共 50 条
  • [1] Accuracy of Leg Length and Offset Measurements During Total Hip Arthroplasty Using an Imageless Navigation System
    Lambers, Anton P.
    Marley, Melanie A.
    Jennings, Robert
    Bucknill, Andrew
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [2] Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    C. Schnurr
    J. W. P. Michael
    P. Eysel
    D. P. König
    International Orthopaedics, 2009, 33 : 365 - 372
  • [3] Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    Schnurr, C.
    Michael, J. W. P.
    Eysel, P.
    Koenig, D. P.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 365 - 372
  • [4] Use of Imageless Navigation in the Conversion of Hip Fusion to Total Hip Arthroplasty
    Kuzyk, Paul
    Gross, Allan
    Lamb, Iain R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [5] Imageless navigation total hip arthroplasty - an evaluation of operative time
    Valsamis, Epaminondas Markos
    Ricketts, David
    Hussain, Adnan
    Jenabzadeh, Amir-Reza
    SICOT-J, 2018, 4
  • [6] Accuracy of Imageless Computer Assisted Navigation System through in Total Hip Arthroplasty in vitro and in vivo Studies
    Lim, D.
    Lin, F.
    Wixson, R.
    Hendrix, R.
    MacDonald, M.
    Makhsous, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3044 - +
  • [7] Limitations of Imageless Computer-Assisted Navigation for Total Hip Arthroplasty
    Lin, Fang
    Lim, Dohyung
    Wixson, Richard L.
    Milos, Steven
    Hendrix, Ronald W.
    Makhsous, Mohsen
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 596 - 605
  • [8] Imageless Computer Navigation of Hip Resurfacing Arthroplasty
    Schnurr, Christoph
    Nessler, Jochen
    Koebke, Juergen
    Michael, Joern William
    Eysel, Peer
    Koenig, Dietmar Pierre
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2010, 22 (03): : 307 - 316
  • [9] Imageless navigation for primary total hip arthroplasty: a meta-analysis study
    Migliorini, Filippo
    Cuozzo, Francesco
    Oliva, Francesco
    Eschweiler, Joerg
    Hildebrand, Frank
    Maffulli, Nicola
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 23 (01)
  • [10] Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion
    Chang, Jun-Dong
    Kim, In-Sung
    Prabhakar, Sharad
    Mansukhani, Sameer A.
    Lee, Sang-Soo
    Yoo, Je-Hyun
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1576 - 1580