Determination of phenols in environmental waters using liquid chromatography with electrochemical detection

被引:17
|
作者
Paterson, B
Cowie, CE
Jackson, PE
机构
[1] WATERS AUSTRALIA PTY LTD,RYDALMERE,NSW 2116,AUSTRALIA
[2] NSW ENVIRONM PROTECT AUTHORITY,LICOMBE,NSW 2141,AUSTRALIA
关键词
electrochemical detector; water analysis; environmental analysis; phenols;
D O I
10.1016/0021-9673(95)01192-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of a liquid chromatographic method for the determination of priority pollutant phenols at low mu g/l levels in environmental waters is discussed. The phenols were separated using a Nova-Pak Phenyl column with concave gradient elution from 20 mM ammonium acetate (19% acetonitrile) to 20 mM ammonium acetate (54% acetonitrile) over 12 min, and subsequently detected using an electrochemical detector equipped with a glassy carbon working electrode, operated at a potential of + 1150 mV. This approach resulted in minimal sample interferences and practical quantitation limits in the low mu g/l range. The LC-ED method offers a distinct advantage over the established GC and GC-MS phenol methods in that no sample extraction is required, hence avoiding the losses which occur during the extraction, concentration and solvent exchange steps required for the GC-based analyses. The method was evaluated through participation in a round robin testing program, involving determination of the eleven priority pollutant phenols in environmental water matrices. The results and recoveries obtained using the LC-ED method compared well with the overall consensus results, with recoveries ranging from 75% up to 118% for the eleven phenols. The between-laboratory reproducibility data indicated a high level of collective proficiency, with the overall average coefficients of variation for the eleven analytes being 18%, 18% and 13%, for spiked oil refinery effluent, paper mill effluent and reagent water samples, respectively.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [31] TRACE DETERMINATION OF PHENOLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AN ELECTROCHEMICAL DETECTOR
    ISHII, Y
    ASAKURA, K
    SAKAMOTO, T
    JOURNAL OF PESTICIDE SCIENCE, 1990, 15 (03): : 445 - 448
  • [32] Determination of phenols in water samples using a supported liquid membrane extraction probe and liquid chromatography with photodiode array detection
    Chimuka, Luke
    Nefale, Flora
    Masevhe, Anox
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2007, 60 : 102 - 108
  • [33] DETERMINATION OF SALBUTAMOL IN RATS AT LOW CONCENTRATIONS USING LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    RAMOS, F
    CASTILHO, MC
    DASILVEIRA, MIN
    PRATES, JAM
    CORREIA, JHR
    ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) : 279 - 283
  • [34] THE FORENSIC DETERMINATION OF DRUGS OF ABUSE USING LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - A REVIEW
    SELAVKA, CM
    KRULL, IS
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3): : 345 - 375
  • [35] Determination of isoflavones in soybean food and human urine using liquid chromatography with electrochemical detection
    Klejdus, B
    Vacek, J
    Adam, V
    Zehnálek, J
    Kizek, R
    Trnková, L
    Kubán, V
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (02): : 101 - 111
  • [36] SENSITIVE METHOD FOR DETERMINATION OF PLASMA CATECHOLAMINES USING LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    HALLMAN, H
    FARNEBO, LO
    HAMBERGER, B
    JONSSON, G
    LIFE SCIENCES, 1978, 23 (10) : 1049 - 1052
  • [37] Simultaneous determination of eight estrogens and their metabolites in serum using liquid chromatography with electrochemical detection
    Piwowarska, Jadwiga
    Radowicki, Stanislaw
    Pachecka, Jan
    TALANTA, 2010, 81 (1-2) : 275 - 280
  • [38] DETERMINATION OF 4-HYDROXYANISOLE IN SERUM USING LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    BUELL, PE
    GIRARD, JE
    LIFE SCIENCES, 1984, 34 (26) : 2605 - 2611
  • [39] DETERMINATION OF METANEPHRINES IN PLASMA BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    LENDERS, JWM
    EISENHOFER, G
    ARMANDO, I
    KEISER, HR
    GOLDSTEIN, DS
    KOPIN, IJ
    CLINICAL CHEMISTRY, 1993, 39 (01) : 97 - 103
  • [40] Determination of neomycin sulfate by liquid chromatography with pulsed electrochemical detection
    Adams, E
    Schepers, R
    Roets, E
    Hoogmartens, J
    JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (02) : 233 - 240