High frequency single element and annular array transducers incorporating PVDF

被引:6
|
作者
Alves, CHF
Snook, K
Ritter, T
Shung, KK
机构
关键词
high frequency ultrasonic transducers; annular arrays; electrical matching; ultrasound backscatter microscopy;
D O I
10.1117/12.382219
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyvinylidene fluoride (PVDF) transducers have been developed for ultrasonic backscatter microscopy (UBM) applications. Single element devices encompassed the frequency range of 40 to 65 MHz and incorporated a variety of backing materials and tuning circuits. Pulse-echo testing was performed using the 1 mu J energy setting on a Panametrics 5900 pulser/receiver, configured with +40dB gain and 20dB attenuation. A broad spectrum of performance was observed depending on the choice of backing and tuning, with -6dB bandwidths of 55% to 116% and echo amplitudes from 100mVpp to 940mVpp. It was observed that electrical impedance matching increased sensitivity and tuned the center frequency at the expense of reduced bandwidth. For imaging applications the tuned devices provided superior performance. Although single element transducers in this frequency range provide axial resolution on the order of 50 Gun, a tradeoff exists between the lateral resolution and the depth of held. To obtain high lateral resolution and a long depth of field an annular array design was adopted. Laser dicing was used to fabricate the elements of the array fi om a sheet of PVDF. Interconnect to each element was achieved using pin contacts molded into the backing. The design incorparated a 5mm aperture with six equal area elements focused at 10mm. At a center frequency of 50 MHz this design will achieve a lateral resolution of 58 mu m, comparable to the axial resolution, over the entire 7.5mm depth of field.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 50 条
  • [21] A high frequency synthetic ultrasound array incorporating an actuator
    Ritter, TA
    Shrout, TR
    Shung, KK
    MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2001, 4325 : 36 - 46
  • [22] High frequency P(VDF-TrFE) copolymer broadband annular array ultrasound transducers using high density flexible circuit interconnect
    Gottlieb, EJ
    Cannata, JM
    Hu, CH
    Shung, KK
    MEDICAL IMAGING 2005: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2005, 5750 : 47 - 57
  • [23] PERFORMANCE OF CONCENTRIC ANNULAR PATCHES AS A DUAL FREQUENCY BAND MICROSTRIP ARRAY ELEMENT
    NURIE, NS
    LANGLEY, RJ
    SIXTH INTERNATIONAL CONFERENCE ON ANTENNAS AND PROPAGATION ( ICAP 89 ), PARTS 1-2, 1989, 301 : A144 - A148
  • [24] A Low Cost Receive Beamformer for a High Frequency Annular Array
    Lay, Holly S.
    Lockwood, Geoffrey R.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 462 - 465
  • [25] Integrated circuit for high-frequency ultrasound annular array
    Talman, JR
    Garverick, SL
    Lockwood, GR
    PROCEEDINGS OF THE IEEE 2003 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2003, : 477 - 480
  • [26] Single element high frequency (<50 MHz) PZT sol gel composite ultrasound transducers
    Lukacs, M
    Sayer, M
    Foster, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) : 148 - 159
  • [27] BSPT- and PZNT-based high frequency single element transducers for medical ultrasonic imaging
    Rhee, S
    Zhang, SJ
    Molingou, G
    Shrout, T
    Shung, K
    ISAF 2002: PROCEEDINGS OF THE 13TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, 2002, : 315 - 318
  • [28] Temperature dependence of high frequency parameters of PVDF for length mode ultrasonic air transducers
    Toda, Minoru
    Thompson, Mitch
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 484 - 487
  • [29] Variable frequency multilayer PVDF transducers for ultrasound imaging
    Zhang, Q
    Lewin, PA
    Bloomfield, PE
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1997, 1997, 3037 : 2 - 12
  • [30] High-frequency linear array transducers for neonatal cerebral sonography
    Thomson, GD
    Teele, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) : 995 - 1001