The concurrent recording of electroencephalography and impedance cardiography: Effects on EEG

被引:4
|
作者
Dalton, KM [1 ]
Davidson, RJ [1 ]
机构
[1] UNIV WISCONSIN, DEPT PSYCHOL, LAB AFFECT NEUROSCI, MADISON, WI 53706 USA
关键词
electroencephalography; impedance cardiography; human;
D O I
10.1111/j.1469-8986.1997.tb02394.x
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Three experiments were performed testing the effects of a variety of impedance cardiograph electrode types and recording arrangements an recorded electroencephalography (EEG) using either a monopolar single-ear reference or a physically linked ears reference. EEG was recorded either alone or concurrently with an impedance cardiograph. When the cardiograph was recorded using a spat electrode for the top current-inducing electrode, there was an overall decrease in power density of the EEG, and this effect was dependent on the location of the recording electrode. This effect was diminished when the top cardiograph spot electrode was replaced by a mylar-coated neck band electrode and EEG was recorded using a monopolar, single-ear reference. However, there tended to be an overall increase in log power density of the EEG in each frequency band below 60 Hz when less technologically advanced EEG amplifiers were used. This effect was diminished if the EEG was recorded using a physically linked ears reference. Recommendations for the concurrent recording of EEG and impedance cardiography are discussed.
引用
收藏
页码:488 / 493
页数:6
相关论文
共 50 条
  • [21] THORACIC IMPEDANCE CARDIOGRAPHY
    SPODICK, DH
    AMERICAN HEART JOURNAL, 1982, 104 (06) : 1392 - 1392
  • [22] A REVIEW OF IMPEDANCE CARDIOGRAPHY
    JENSEN, L
    YAKIMETS, J
    TEO, KK
    HEART & LUNG, 1995, 24 (03): : 183 - 193
  • [23] CONSIDERATIONS ON IMPEDANCE CARDIOGRAPHY
    CASTHELY, P
    RAMANATHAN, S
    CHALON, J
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1980, 27 (05) : 481 - 484
  • [24] THE VALIDITY OF IMPEDANCE CARDIOGRAPHY
    BUELL, JC
    MCKINNEY, ME
    BECK, B
    MEYERS, D
    ELIOT, RS
    PSYCHOPHYSIOLOGY, 1983, 20 (04) : 420 - 420
  • [25] Concurrent Recording of Co-localized Electroencephalography and Local Field Potential in Rodent
    Kang, Sungmin
    Bruyns-Haylett, Michael
    Hayashi, Yurie
    Zheng, Ying
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (129):
  • [26] EEG - ELECTROENCEPHALOGRAPHY
    Hulbert, Harold S.
    JOURNAL OF CRIMINAL LAW & CRIMINOLOGY, 1947, 37 (06): : 491 - 497
  • [27] A flexible, stable, semi-dry electrode with low impedance for electroencephalography recording
    Zhu, Yiyan
    Bayin, Caicaike
    Li, Hongjie
    Shu, Xiaokang
    Deng, Jiangnan
    Yuan, Haowen
    Shen, Huyan
    Liang, Zhou
    Li, Yao
    RSC ADVANCES, 2024, 14 (46) : 34415 - 34427
  • [28] HYPODERMIC CATHODE FOLLOWER FOR DRUG ADMINISTRATION AND CONCURRENT EEG RECORDING
    RUNION, HI
    RIEDESEL, CC
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1965, 54 (05) : 781 - &
  • [30] Impedance cardiography: Recent advancements
    Cybulski, Gerard
    Strasz, Anna
    Niewiadomski, Wiktor
    Gasiorowska, Anna
    CARDIOLOGY JOURNAL, 2012, 19 (05) : 550 - 556