Study and comparison of fault tolerant shunt three-phase active filter topologies

被引:0
|
作者
El Brouji, H. [1 ]
Poure, P. [2 ]
Saadate, S. [1 ]
机构
[1] Univ Nancy 1, GREEN UHP, CNRS UMR 7037, Grp Rech Electrotech & Elect Nancy, BP 239, F-54506 Vandoeuvre Les Nancy, France
[2] Univ Henri Poincare, LIEN, EA 3440, Lab Intrumentat Elect Nancy, Vandoeuvre Les Nancy, France
关键词
active power filter; fault tolerant converter topology; fault detection; converter reconfiguration; fault tolerant control;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper studies 3 fault tolerant shunt three phase active filter topologies. It mainly details converter reconfiguration and uses an optimised fast and reliable fault diagnosis method, avoiding spurious semiconductor fault detection due to semiconductor switching. The fault tolerant converter topologies are based on classical three-leg active power filter topology but includes bi-directional switches for converter reconfiguration after fault detection. The power filter structure, after reconfiguration, could either be a three-leg or a two-leg topology. An unique control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Saber CAD tools validate the theoretical study.
引用
收藏
页码:1669 / +
页数:2
相关论文
共 50 条
  • [21] A Design Method of LCL-filter for Three-phase Shunt Active Power Filter
    Pan, Nan
    Liu, Zhen
    ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS III, 2019, 2073
  • [22] Three-Phase Three-Level Inverter Based Shunt Active Power Filter
    Altin, Necmi
    Kaplan, Orhan
    Ozdemir, Saban
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 799 - 804
  • [23] A Study of a Three-Phase Four-Wire Shunt Active Power Filter for Harmonics Mitigation
    Ayala Maciel, Luis Fernando
    Monroy Morales, Jose Luis
    Marroquin Pimentel, Juan Gabriel
    Campos Gaona, David
    2018 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2018,
  • [24] Current Control Based on Three-Phase Shunt Hybrid Active Power Filter Case Study
    Dai, Wenjin
    Li, Hongyun
    Chen, Ming
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 214 - 219
  • [25] Fuzzy based Fault Tolerant Shunt Active Power Filter
    Madhuri, N.
    Doradla, S. R.
    Kalavathi, M. Surya
    2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2014, : 1334 - 1337
  • [26] Selective Estimation of Three-Phase Mains Current for Shunt Active Power Filter
    Peresada, Sergei
    Zaichenko, Yurii
    Dymko, Serhii
    2020 IEEE 7TH INTERNATIONAL CONFERENCE ON ENERGY SMART SYSTEMS (2020 IEEE ESS), 2020, : 68 - 72
  • [27] Simulation of three-phase four-wire shunt active power filter
    Wang, Ji-Dong
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2007, 40 (SUPPL.): : 95 - 99
  • [28] Linear model of a three-phase shunt active power filter with a hysteresis controller
    Vardar, Kadir
    Akpinar, Eyup
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2016, 24 (02) : 384 - U349
  • [29] Predictive direct power control of three-phase shunt active power filter
    Le, Jiang-Yuan
    Zhang, Zhi
    Lai, Xiao-Hua
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2012, 16 (05): : 86 - 90
  • [30] Three-phase four-wire shunt active filter control strategies
    Aredes, M
    Hafner, J
    Heumann, K
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) : 311 - 318