High resolution non-invasive intraocular pressure monitoring by use of graphene woven fabrics on contact lens

被引:38
|
作者
Zhang, Yushi [1 ,2 ]
Chen, Yufeng [2 ]
Man, Tianxing [2 ]
Huang, Dong [2 ]
Li, Xiao [3 ]
Zhu, Hongwei [3 ,4 ]
Li, Zhihong [2 ,4 ]
机构
[1] Minzu Univ China, Sch Informat Engn, Beijing 100081, Peoples R China
[2] Peking Univ, Inst Microelect, Natl Key Lab Sci & Technol Micro Nano Fabricat, Beijing 100871, Peoples R China
[3] Tsinghua Univ, Dept Mech Engn, Key Lab Adv Mfg Mat Proc Technol, Beijing 100084, Peoples R China
[4] Tsinghua Univ, CNMM, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
SENSOR; PATTERNS; SYSTEMS;
D O I
10.1038/s41378-019-0078-x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Monitoring intracorporal pressures are important for health care and diagnosis. In this work, a contact lens tonometer employing graphene woven fabrics (GWFs), which indicate great sensibility of resistance to strain, flexibility, stretchability, transparency, and biocompatibility, is proposed for real-time monitoring intraocular pressure (IOP) with high resolution. The mechanical properties of the device during the deformation were analyzed, and the sensitivity of the fabricated device was tested on a mimic human eyeball. In vitro experiments on porcine eyes were executed to test the effectiveness of the device. The change rate of resistance under different IOP was tested. Also, the relationship between the current changes and IOP variation when keeping the voltage constant for different devices was obtained. The contact lens tonometers with GWFs as high-resolution sensing element have shown a promising prospective to realize the low-cost disposable sensing contact lens with lower power.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Comparison of invasive and non-invasive intracranial pressure monitoring
    Hamarat, Y.
    Deimantavicius, M.
    Zakelis, R.
    Bartusis, L.
    Preiksaitis, A.
    Ragauska, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 60 - 60
  • [32] A glucose sensing contact lens: A new approach to non-invasive continuous physiological glucose monitoring
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS IV, 2004, 5317 : 234 - 245
  • [33] Contact Lens Sensor with Anti-jamming Capability and High Sensitivity for Intraocular Pressure Monitoring
    Ren, Xueyang
    Zhou, Yunfan
    Lu, Fangzhou
    Zhai, Leili
    Wu, Hao
    Chen, Zhongda
    Wang, Changxian
    Zhu, Xuefei
    Xie, Yandong
    Cai, Pingqiang
    Xu, Juan
    Tang, Xianglong
    Li, Jianqing
    Yao, Jin
    Jiang, Qin
    Hu, Benhui
    ACS SENSORS, 2023, 8 (07): : 2691 - 2701
  • [34] Soft wearable contact lens sensor for continuous intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Leung, Leo K. K.
    Lam, David C. C.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1134 - 1139
  • [35] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Joohee Kim
    Jihun Park
    Young-Geun Park
    Eunkyung Cha
    Minjae Ku
    Hyeon Seok An
    Kyoung-Pil Lee
    Man-Il Huh
    Junmo Kim
    Taek-Soo Kim
    Dai Woo Kim
    Hong Kyun Kim
    Jang-Ung Park
    Nature Biomedical Engineering, 2021, 5 : 772 - 782
  • [36] Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring
    Sanchez, Irene
    Laukhin, Vladimir
    Moya, Ana
    Martin, Raul
    Ussa, Fernando
    Laukhina, Elena
    Guimera, Anton
    Villa, Rosa
    Rovira, Concepcio
    Aguilo, Jordi
    Veciana, Jaume
    Pastor, Jose C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 8310 - 8315
  • [37] Design of wireless contact-lens antenna for intraocular pressure monitoring
    Priya, L.
    Vijitha, J.
    Alagappan, M.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) : 315 - 323
  • [38] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Kim, Joohee
    Park, Jihun
    Park, Young-Geun
    Cha, Eunkyung
    Ku, Minjae
    An, Hyeon Seok
    Lee, Kyoung-Pil
    Huh, Man-Il
    Kim, Junmo
    Kim, Taek-Soo
    Kim, Dai Woo
    Kim, Hong Kyun
    Park, Jang-Ung
    NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) : 772 - 782
  • [39] Non-invasive arterial pressure monitoring revisited
    Frederic Michard
    Daniel I. Sessler
    Bernd Saugel
    Intensive Care Medicine, 2018, 44 : 2213 - 2215
  • [40] Non-invasive blood pressure monitoring in man
    Portaluppi, F
    PATHOLOGIE BIOLOGIE, 1996, 44 (03): : 196 - 200