Mitigation Impacts of Non-Severe Unbalanced Grid Faults Based Wind Driven DFIG

被引:0
|
作者
Ahmed, G. E. [1 ]
Mohmed, H. A. [2 ]
Kamel, O. M. [2 ]
机构
[1] Asuit Univ, Fac Engn, Asyut, Egypt
[2] El Minia High Inst Engn & Technol, Abu Qurqas, Menia Governora, Egypt
关键词
Doubly fed induction generator (DFIG); space vector modulation (SVM); Wind turbine (WT);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a voltage vector control method based on space vector modulation to govern both the RSC and GSC of a wind driven DFIG during non-severe voltage conditions specially unbalanced faults. The main contribution of this work is to provide an effective voltage vector control that can mitigate problems caused by the unbalanced non-sever faults by making co-ordination between the RSC and the GSC without using any external elements. Simulation results obtained prove that the proposed control system has a fast dynamic response and improves the DFIG stability by decreasing torque pulsation, reducing ripples of the dc-link voltage of back to back converter and making the recovery time less. The results are compared to the conventional PI regulator method used for controlling the back-to-back converters of the DFIG and the proposed technique proves its compactness and robustness for providing better dynamic performance.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [21] Grid-Voltage-Oriented Sliding Mode Control for DFIG Under Balanced and Unbalanced Grid Faults
    Villanueva, Ivan
    Rosales, Antonio
    Ponce, Pedro
    Molina, Arturo
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2018, 9 (03) : 1090 - 1098
  • [22] A DFIG-based Wind Turbine Operation under Balanced and Unbalanced Grid Voltage Conditions
    Boukili, Yassine
    Aguiar, A. Pedro
    Carvalho, Adriano
    IFAC PAPERSONLINE, 2020, 53 (02): : 12835 - 12840
  • [23] Control and Protection of a DFIG-Based Wind Turbine under Unbalanced Grid Voltage Dips
    Zhou, Peng
    He, Yikang
    Sun, Dan
    Zhu, Jianguo
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 2375 - +
  • [24] Experimental investigation of grid-connected operations for DFIG-based wind turbines with asymmetrical grid faults
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2013, 53 (07): : 1036 - 1040
  • [25] DFIG Based Wind Turbine Protection Using Active Crowbar and SVC during Grid Faults
    Hassan, Heba Ahmed
    2018 8TH IEEE INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2018,
  • [26] Ride-Through and Grid Support of the DFIG based Wind Farm During Asymmetrical Faults
    Geng, Hua
    Yang, Geng
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1182 - 1188
  • [27] Protection System Behavior of DFIG Based Wind Farms for Grid-Faults with Practical Considerations
    Kawady, Tamer
    Feltes, Christian
    Erlich, Istvan
    Taalab, A. I.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [28] Comparative Analysis of Control Strategies for DFIG Based Wind System under Small Grid Faults
    Skander-Mustapha, S.
    Jebali-Ben Ghorbal, M.
    Arbi, J.
    Slama-Belkhodja, I.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (06): : 1273 - 1282
  • [29] Capability of Asymmetrical Grid Faults Ride-through for DFIG-based Wind Turbines
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 3533 - 3540
  • [30] Review of Control Strategies for DFIG-Based Wind Turbines under Unsymmetrical Grid Faults
    Tourou, Pavlos
    Sourkounis, Constantinos
    2014 NINTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2014,