Mitigation Impacts of Non-Severe Unbalanced Grid Faults Based Wind Driven DFIG

被引:0
|
作者
Ahmed, G. E. [1 ]
Mohmed, H. A. [2 ]
Kamel, O. M. [2 ]
机构
[1] Asuit Univ, Fac Engn, Asyut, Egypt
[2] El Minia High Inst Engn & Technol, Abu Qurqas, Menia Governora, Egypt
关键词
Doubly fed induction generator (DFIG); space vector modulation (SVM); Wind turbine (WT);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a voltage vector control method based on space vector modulation to govern both the RSC and GSC of a wind driven DFIG during non-severe voltage conditions specially unbalanced faults. The main contribution of this work is to provide an effective voltage vector control that can mitigate problems caused by the unbalanced non-sever faults by making co-ordination between the RSC and the GSC without using any external elements. Simulation results obtained prove that the proposed control system has a fast dynamic response and improves the DFIG stability by decreasing torque pulsation, reducing ripples of the dc-link voltage of back to back converter and making the recovery time less. The results are compared to the conventional PI regulator method used for controlling the back-to-back converters of the DFIG and the proposed technique proves its compactness and robustness for providing better dynamic performance.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [1] Detailed study of DFIG-based wind turbines to overcome the most severe grid faults
    Rolan, Alejandro
    Pedra, Joaquin
    Corcoles, Felipe
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 868 - 878
  • [2] Evaluation of the Effect of Voltage Sags Due to Grid Balanced and Unbalanced Faults on DFIG Wind Turbines
    Yan, Xiangwu
    Venkataramanan, Giri
    Flannery, P. S.
    Wang, Yang
    Zhang, Bo
    EPE JOURNAL, 2010, 20 (04) : 51 - 61
  • [3] Modeling a DFIG Based Wind System for Unbalanced Grid Voltage Condition
    El Archi, Choroq. Z.
    Nasser, Tamou
    Alvarado, Jorge
    2017 19TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEM APPLICATION TO POWER SYSTEMS (ISAP), 2017,
  • [4] Parallel Working of DFIG Based Wind Systems under Unbalanced Grid Conditions
    Ghodbane-Cherif, Meriem
    Skander-Mustapha, Sondes
    Slama-Belkhodja, Ilhem
    2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,
  • [5] Dynamic behavior of DFIG-based wind turbines during grid faults
    Erlich, I.
    Wrede, H.
    Feltes, C.
    2007 POWER CONVERSION CONFERENCE - NAGOYA, VOLS 1-3, 2007, : 1162 - +
  • [6] Advanced Protection Schemes for DFIG Based Wind Turbines during the Grid Faults
    Abofard, Alaa Eldin M.
    El-Zohri, Emad H.
    Mahmoud, Heba A.
    Ziedan, Hamdy A.
    2016 INTERNATIONAL CONFERENCE ON SYSTEM RELIABILITY AND SCIENCE (ICSRS 2016), 2016, : 33 - 41
  • [7] Voltage Enhancement on DFIG Based Wind Farm Terminal During Grid Faults
    Phan Dinh Chung
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2019, 9 (05) : 4783 - 4788
  • [8] Line Faults Analysis of DFIG Driven by Wind Turbine
    Thabit, M. M.
    Elzoghby, Helmy
    El-Korfolly, M. I.
    2019 IEEE CONFERENCE ON POWER ELECTRONICS AND RENEWABLE ENERGY (IEEE CPERE), 2019, : 573 - 578
  • [9] Enhancing the performance of grid synchronization in DFIG-based wind turbine under unbalanced grid conditions
    Ali Ghasemi
    Mohammad Hossein Refan
    Parviz Amiri
    Electrical Engineering, 2020, 102 : 1175 - 1194
  • [10] Enhancing the performance of grid synchronization in DFIG-based wind turbine under unbalanced grid conditions
    Ghasemi, Ali
    Refan, Mohammad Hossein
    Amiri, Parviz
    ELECTRICAL ENGINEERING, 2020, 102 (03) : 1175 - 1194