Observational study on primary and secondary stability of two current bone level implant designs

被引:2
|
作者
Steiner, Constanze [1 ]
Karl, Matthias [1 ]
Steiner, Dirk [2 ]
Meyer, Birgit [1 ]
机构
[1] Saarland Univ, Dept Prosthodont, Kirrberger Str 1, D-66421 Homburg, Germany
[2] Private Practice Zahnarztpraxis Sonnenfeld, Homburg, Germany
来源
QUINTESSENCE INTERNATIONAL | 2021年 / 52卷 / 03期
关键词
bone quality; implant design; insertion torque; primary stability; resonance frequency analysis; INSERTION TORQUE; MARGINAL BONE; IN-VITRO; SURFACE;
D O I
10.3290/j.qi.a45605
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Achieving high levels of primary implant stability is considered to be desirable, despite some studies warning of the risk of bone damage. It was the goal of this observational clinical study to compare two current bone level implant systems with respect to primary and secondary stability. Method and materials: Data on bone quality, insertion torque, implant stability at insertion and after healing, as well as number of implants lost during healing were obtained from two centers either placing BLT (Bone Level Tapered, Straumann) or Nobel Parallel CC (Nobel Biocare) implants. Statistical analysis was based on Spearman rank correlation tests, analysis of variance, and t tests with the level of significance set at alpha = .05. Results: A total of 312 BLT and 92 Nobel Parallel CC implants were placed.Ten BLT and two Nobel Parallel CC implants failed resulting in survival rates of 96.79% and 97.83%, respectively. Mean insertion torque recorded in the different bone classes showed large standard deviations, and only torque values for BLT implants recorded in type 3 bone differed significantly from type 2 bone and type 1 bone (P = .024). For BLT implants, bone quality and insertion torque correlated (Spearman rho = -.3326; P = .0023)as did ISQ at insertion (Spearman rho = -.2241; P = .0429). Implant diameter significantly affected primary (P = .0013) and secondary (P = .0050) stability of Nobel Parallel CC implants while for BLT implants a significant effect was only seen for secondary stability (P = .0000). Bone quality had a significant effect on implant insertion torque for BLT implants (P = .0059). Bone quality had no general effect on ISQ changes during healing but 3.3-mm BLT implants showed significantly (P = .0005) lower stability after healing. Conclusion: Huge variation with respect to primary and secondary stability seems to exist among similar looking implant systems clinically used for identical indications.
引用
收藏
页码:230 / 235
页数:6
相关论文
共 50 条
  • [41] Comparison of Primary Stability of Two Different Implants Designs-A Prospective Clinical Study
    Sravanthi, A. Veena
    Manne, Prakash
    Surapaneni, Haragopal
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (01) : ZC16 - ZC19
  • [42] Monitoring crestal bone level of single- and two-stage implant placement modes up to final prosthetic delivery: an observational study
    Artzi, Zvi
    Shlafstein, Rachel
    [J]. QUINTESSENCE INTERNATIONAL, 2021, 52 (03): : 236 - 246
  • [43] The effect of implant length and diameter on primary stability of tilted implant on D4 bone density: An in vitro study
    Baihaqi, Muhammad, I
    Sumarsongko, Taufik
    Bonifacius, Setyawan
    [J]. JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (05): : 487 - 493
  • [44] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Annette Rabel
    Steffen Gerhard Köhler
    Andrea Maria Schmidt-Westhausen
    [J]. Clinical Oral Investigations, 2007, 11 : 257 - 265
  • [45] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Rabel, Annette
    Koehler, Steffen Gerhard
    Schmidt-Westhausen, Andrea Maria
    [J]. CLINICAL ORAL INVESTIGATIONS, 2007, 11 (03) : 257 - 265
  • [46] Implant stability and marginal bone level changes: A 2-year prospective pilot study
    Fu, Po-Sung
    Lan, Ting-Hsun
    Lai, Pei-Ling
    Chen, Cheng-Hwei
    Chen, Jen-Hao
    Wang, Jen-Chyan
    Liu, Chih-Te
    Chen, Wen-Cheng
    Hung, Chun-Cheng
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (03) : 1272 - 1279
  • [47] Influence of Mucosal Thickness, Implant Dimensions and Stability in Cone Morse Implant Installed at Subcrestal Bone Level on the Peri-Implant Bone: A Prospective Clinical and Radiographic Study
    Gehrke, Sergio Alexandre
    Bercianos, Mauro
    Aguerrondo, Jorge Gonzalo
    Calvo-Guirado, Jose Luis
    Prados-Frutos, Juan Carlos
    [J]. SYMMETRY-BASEL, 2019, 11 (09):
  • [48] The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study
    Mikic, Mirko
    Vlahovic, Zoran
    Nenezic, Dragoslav
    Videnovic, Goran
    Ilic, Danijela
    Mladenovic, Rasa
    [J]. VOJNOSANITETSKI PREGLED, 2021, 78 (08) : 811 - 817
  • [49] Can Bone Compaction Improve Primary Implant Stability? An In Vitro Comparative Study with Osseodensification Technique
    Antonelli, Alessandro
    Bennardo, Francesco
    Brancaccio, Ylenia
    Barone, Selene
    Femiano, Felice
    Nucci, Ludovica
    Minervini, Giuseppe
    Fortunato, Leonzio
    Attanasio, Ferdinando
    Giudice, Amerigo
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 13
  • [50] Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study
    Han, Ho-Chyul
    Lim, Hyun-Chang
    Hong, Ji-Youn
    Ahn, Su-Jin
    Han, Ji-Young
    Shin, Seung-Il
    Chung, Jong-Hyuk
    Herr, Yeek
    Shin, Seung-Yun
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (04): : 254 - 265