Quantification of 1.5 T T1 and T2* Relaxation Times of Fetal Tissues in Uncomplicated Pregnancies

被引:12
|
作者
Sethi, Simran [1 ]
Giza, Stephanie A. [1 ]
Goldberg, Estee [2 ]
Empey, Mary-Ellen E. T. [1 ]
de Ribaupierre, Sandrine [2 ,3 ,4 ,5 ]
Eastabrook, Genevieve D. M. [5 ,6 ,7 ]
de Vrijer, Barbra [5 ,6 ,7 ]
McKenzie, Charles A. [1 ,5 ]
机构
[1] Western Univ, Dept Med Biophys, London, ON, Canada
[2] Western Univ, Dept Biomed Engn, London, ON, Canada
[3] London Hlth Sci Ctr, Dept Clin Neurol Sci, London, ON, Canada
[4] Western Univ, Brain & Mind Inst, London, ON, Canada
[5] Childrens Hlth Res Inst, Div Maternal Fetal & Newborn Hlth, London, ON, Canada
[6] Western Univ, Schulich Sch Med & Dent, London, ON, Canada
[7] Western Univ, Dept Obstet & Gynaecol, London, ON, Canada
关键词
pregnancy; fetus; tissue relaxometry; chemical‐ shift encoded MRI;
D O I
10.1002/jmri.27547
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Despite its many advantages, experience with fetal magnetic resonance imaging (MRI) is limited, as is knowledge of how fetal tissue relaxation times change with gestational age (GA). Quantification of fetal tissue relaxation times as a function of GA provides insight into tissue changes during fetal development and facilitates comparison of images across time and subjects. This, therefore, can allow the determination of biophysical tissue parameters that may have clinical utility. Purpose To demonstrate the feasibility of quantifying previously unknown T-1 and T-2* relaxation times of fetal tissues in uncomplicated pregnancies as a function of GA at 1.5 T. Study Type Pilot. Population Nine women with singleton, uncomplicated pregnancies (28-38 weeks GA). Field Strength/Sequence All participants underwent two iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-IQ) acquisitions at different flip angles (6 degrees and 20 degrees) at 1.5 T. Assessment Segmentations of the lungs, liver, spleen, kidneys, muscle, and adipose tissue (AT) were conducted using water-only images and proton density fat fraction maps. Driven equilibrium single pulse observation of T-1 (DESPOT1) was used to quantify the mean water T-1 of the lungs, intraabdominal organs, and muscle, and the mean water and lipid T-1 of AT. IDEAL T-2* maps were used to quantify the T-2* values of the lungs, intraabdominal organs, and muscle. Statistical Tests F-tests were performed to assess the T-1 and T-2* changes of each analyzed tissue as a function of GA. Results No tissue demonstrated a significant change in T-1 as a function of GA (lungs [P = 0.89]; liver [P = 0.14]; spleen [P = 0.59]; kidneys [P = 0.97]; muscle [P = 0.22]; AT: water [P = 0.36] and lipid [P = 0.14]). Only the spleen and muscle T-2* showed a significant decrease as a function of GA (lungs [P = 0.67); liver [P = 0.05]; spleen [P < 0.05]; kidneys [P = 0.70]; muscle [P < 0.05]). Data Conclusion These preliminary data suggest that the T-1 of the investigated tissues is relatively stable over 28-38 weeks GA, while the T-2* change in spleen and muscle decreases significantly in that period. Level of Evidence 3 Technical Efficacy Stage 2
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [31] Assessment of magnetic resonance imaging scanner-dependence and software-dependence of T1 and T2 relaxation times measurements at 1.5 T
    Cicolari, D.
    Lizio, D.
    Pedrotti, P.
    Sironi, R.
    Moioli, M. T.
    Lascialfari, A.
    Mariani, M.
    Milazzo, A.
    Quattrocchi, G.
    Sormani, P.
    Torresin, A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 327 - 327
  • [32] Magnetic Resonance Fingerprinting Using Echo-Planar Imaging: Joint Quantification of T1 and T2* Relaxation Times
    Rieger, Benedikt
    Zimmer, Fabian
    Zapp, Jascha
    Weingaertner, Sebastian
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1724 - 1733
  • [33] T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER
    BREGER, RK
    RIMM, AA
    FISCHER, ME
    PAPKE, RA
    HAUGHTON, VM
    RADIOLOGY, 1989, 171 (01) : 273 - 276
  • [34] Quantification of NAD+ T1 and T2 Relaxation Times Using Downfield 1H MRS at 7 T in Human Brain In Vivo
    Swago, Sophia
    Wilson, Neil E.
    Elliott, Mark A.
    Nanga, Ravi Prakash Reddy
    Reddy, Ravinder
    Witschey, Walter R.
    NMR IN BIOMEDICINE, 2025, 38 (03)
  • [35] Comparison of myocardial T1 and T2 values in 3 T with T2*in 1.5 T in patients with iron overload and controls
    Camargo, Gabriel C.
    Rothstein, Tamara
    Junqueira, Flavia P.
    Fernandes, Elsa
    Greiser, Andreas
    Strecker, Ralph
    Pessoa, Viviani
    Lima, Ronaldo S. L.
    Gottlieb, Ilan
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2016, 103 (05) : 530 - 536
  • [36] Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls
    Gabriel C. Camargo
    Tamara Rothstein
    Flavia P. Junqueira
    Elsa Fernandes
    Andreas Greiser
    Ralph Strecker
    Viviani Pessoa
    Ronaldo S. L. Lima
    Ilan Gottlieb
    International Journal of Hematology, 2016, 103 : 530 - 536
  • [37] Effect of paramagnetic species on T1, T2 and T1/T2 NMR relaxation times of liquids in porous CuSO4/Al2O3
    D'Agostino, Carmine
    Brauer, Pierre
    Charoen-Rajapark, Pavida
    Crouch, Matthew D.
    Gladden, Lynn F.
    RSC ADVANCES, 2017, 7 (57) : 36163 - 36167
  • [38] Measurement of T1 and T2 relaxation times of the pancreas at 7 T using a multi-transmit system
    Damen, Mariska
    van Leeuwen, Maarten
    Webb, Andrew
    Klomp, Dennis
    de Castro, Catalina Arteaga
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (06) : 703 - 708
  • [39] In vivo measurement of T1 and T2 relaxation times in awake pigeon and rat brains at 7T
    Behroozi, Mehdi
    Chwiesko, Caroline
    Stroeckens, Felix
    Sauvage, Magdalena
    Helluy, Xavier
    Peterburs, Jutta
    Guentuerkuen, Onur
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 1090 - 1100
  • [40] Measurement of T1 and T2 relaxation times of the pancreas at 7 T using a multi-transmit system
    Mariska Damen
    Maarten van Leeuwen
    Andrew Webb
    Dennis Klomp
    Catalina Arteaga de Castro
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 703 - 708