Investigation of hydrodynamic and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns

被引:14
|
作者
Amani, Pouria [1 ]
Amani, Mohammad [2 ]
Hasanvandian, Reza [1 ]
机构
[1] Univ Tehran, Sch Engn, Dept Chem Engn, Tehran, Iran
[2] Shahid Beheshti Univ, Mech & Energy Engn Dept, Tehran, Iran
关键词
Liquid-liquid Extraction; Mercaptan Removal; Pulsed Packed Column; Sulfrex Process; Axial Dispersion Model; LIQUID-LIQUID-EXTRACTION; DISPERSED-PHASE HOLDUP; DROP SIZE DISTRIBUTION; CHARACTERISTIC VELOCITY; STRUCTURED PACKING; AXIAL-DISPERSION; BED COLUMN; REMOVAL; SIMULATION; MODEL;
D O I
10.1007/s11814-017-0042-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We investigated the hydrodynamic behavior and mass transfer characteristics of a pilot-scale conventional packed bed extraction column of mercaptan removal from liquid propane. The extraction column was filled with pall rings structured packing where mercaptan was extracted from the continuous phase to the dispersed phase, accompanied by a chemical reaction in propane-mercaptan-caustic system. The pulsing was introduced into the column to enhance the mass transfer rate. Hydrodynamic parameters such as hold up, flooding velocity and mean drop size were studied together with the effect of chemical reaction on increasing mass transfer performance. Finally, the mass transfer and axial mixing coefficients were obtained from the optimization of data by ADM. It was found that at the pulsation intensity from 0.003 to 0.007 m/s, the maximum mass transfer and minimum axial mixing occurred and it can be concluded that pulsation improves the efficiency of mass transfer just at low intensities.
引用
收藏
页码:1456 / 1465
页数:10
相关论文
共 50 条
  • [31] Experimental Investigation and CFD Modeling of Hydrodynamic Parameters in a Pulsed Packed Column
    Mirzaie, Maryam
    Sarrafi, Amir
    Pour, Hasan Hashemi
    Baghaie, Ali
    Molaeinasab, Mehdi
    SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (07) : 643 - 660
  • [32] Pulsed and non-pulsed OFDM ultra wideband wireless personal area networks
    Saberinia, E
    Tewfik, AH
    2003 IEEE CONFERENCE ON ULTRA WIDEBAND SYSTEMS AND TECHNOLOGIES, CONFERENCE PROCEEDINGS, 2003, : 275 - 279
  • [33] STUDIES ON THE OPERATING CHARACTERISTICS OF PULSED PACKED COLUMNS FOR LIQUID/LIQUID EXTRACTION.
    Bender, Eberhard
    Berger, Rosemarie
    Leuckel, Wolfgang
    Wolf, Dieter
    International chemical engineering, 1981, 21 (01): : 29 - 39
  • [34] SUITABILITY OF NON-PULSED SIEVE PLATE COLUMNS FOR LIQUID LIQUID EXTRACTION OF SYSTEMS OF MATERIALS HAVING LOW SURFACE-TENSION
    HIRSCHMANN, K
    BLASS, E
    CHEMIE INGENIEUR TECHNIK, 1983, 55 (12) : 990 - 991
  • [35] MASS-TRANSFER FROM SINGLE DROPS IN ROTATING-DISK, PULSED SIEVE PLATE AND PACKED LIQUID-LIQUID-EXTRACTION COLUMNS
    BAHMANYAR, H
    CHANGKAKOTI, DK
    GARRO, L
    LIANG, TB
    SLATER, MJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1990, 68 (01): : 74 - 83
  • [36] The inhibition of Colletotrichum acutatum by monochromic pulsed and non-pulsed radiation at different time durations
    Rasiukeviciute, N.
    Brazaityte, A.
    Valiuskaite, A.
    Vastakaite-Kairiene, V.
    IX INTERNATIONAL STRAWBERRY SYMPOSIUM, 2021, 1309 : 711 - 717
  • [37] PACKED-COLUMNS WITH AND WITHOUT PULSED GAS-PHASE .4. GAS MASS-TRANSFER
    SICARDI, S
    GIANETTO, A
    QUADERNI DELL INGEGNERE CHIMICO ITALIANO, 1975, 11 (02): : 31 - 35
  • [38] PACKED-COLUMNS WITH AND WITHOUT PULSED GAS-PHASE .3. LIQUID MASS-TRANSFER
    SICARDI, S
    GIANETTO, A
    QUADERNI DELL INGEGNERE CHIMICO ITALIANO, 1975, 11 (02): : 25 - 30
  • [39] Microwave power FET DC model extraction through isothermal non-pulsed measurements
    Torregrosa-Penalva, German
    Asensio-Lopez, Alberto
    Blanco-del-Campo, Alvaro
    Fernandez-Gonzalez, Jorge
    2006 EUROPEAN MICROWAVE INTEGRATED CIRCUITS CONFERENCE, 2006, : 340 - +
  • [40] Simulation of a pulsed packed extraction column
    Arimont, K
    Soika, M
    Henschke, M
    CHEMIE INGENIEUR TECHNIK, 1996, 68 (03) : 276 - 279