Validation of gravimetry for high-accuracy analysis of uranium

被引:3
|
作者
Ruas, Alexandre [1 ]
Ben Messaoud, Warda [1 ]
Rivier, Cedric [1 ]
Solinhac, Isabelle [1 ]
Le Roudil, Danie [1 ]
机构
[1] CEA, Radio Chem Processes Dept, Nucl Energy Div, F-30207 Bagnols Sur Ceze, France
关键词
Analysis; Gravimetry; Calcination; Uranium; Method validation; Uncertainty; THERMAL-DECOMPOSITION; URANYL-NITRATE; MEASUREMENT UNCERTAINTY; DEHYDRATION;
D O I
10.1007/s10967-016-5116-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gravimetry after calcination is an assay method for determining the quantity of a given element from the mass measurement. This method, adapted for high concentration and purity uranium solution, has the advantage of not being related to a chemical standard and of having an extremely high trueness and precision. Besides, the method is simple, robust and cost-effective. The results of the analytical method validation are shown. Expanded uncertainties, assessed thanks to a reference uranium nitrate solution, are lower than 0.2%. The technique can thus be used in addition to the well-known isotopic dilution thermal-ionisation mass-spectrometry.
引用
收藏
页码:1831 / 1838
页数:8
相关论文
共 50 条
  • [21] HIGH-ACCURACY BATTERY TIMER
    MITCHELL, KW
    ELECTRONIC ENGINEERING, 1980, 52 (639): : 29 - 29
  • [22] HIGH-ACCURACY STRAIGHTENING OF TUBES
    KARASEVICH, PP
    SAVCHENKO, YV
    RASIN, GV
    STOLOVITSKII, VI
    STEEL IN THE USSR, 1986, 16 (08): : 392 - 393
  • [23] HIGH-ACCURACY SHF HYGROMETER
    LEBEDEV, IV
    METSNER, EP
    POTAPOV, AA
    MEASUREMENT TECHNIQUES USSR, 1985, 28 (07): : 674 - 676
  • [24] High-accuracy moisture meter
    不详
    PROFESSIONAL ENGINEERING, 2001, 14 (22) : 44 - 44
  • [25] High-accuracy corneal topographer
    Rottenkolber, M
    Podbielska, H
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 : 92 - 98
  • [26] PRECISION CERAMICS FOR HIGH-ACCURACY
    ZILLING, F
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1989, 97 (07): : ZM96 - &
  • [27] THE HIGH-ACCURACY UNIVERSAL POLARIMETER
    DIJKSTRA, E
    MEEKES, H
    KREMERS, M
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (10) : 1861 - 1868
  • [28] Sequential Design and Analysis of High-Accuracy and Low-Accuracy Computer Codes
    Xiong, Shifeng
    Qian, Peter Z. G.
    Wu, C. F. Jeff
    TECHNOMETRICS, 2013, 55 (01) : 37 - 46
  • [29] HIGH-ACCURACY CHROMIUM PLATING
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1975, 126 (3254): : 353 - 353
  • [30] HIGH-ACCURACY BLEND CONTROL
    POMFRET, JD
    JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS, 1973, 24 (09): : 593 - 605