Validation of gravimetry for high-accuracy analysis of uranium

被引:3
|
作者
Ruas, Alexandre [1 ]
Ben Messaoud, Warda [1 ]
Rivier, Cedric [1 ]
Solinhac, Isabelle [1 ]
Le Roudil, Danie [1 ]
机构
[1] CEA, Radio Chem Processes Dept, Nucl Energy Div, F-30207 Bagnols Sur Ceze, France
关键词
Analysis; Gravimetry; Calcination; Uranium; Method validation; Uncertainty; THERMAL-DECOMPOSITION; URANYL-NITRATE; MEASUREMENT UNCERTAINTY; DEHYDRATION;
D O I
10.1007/s10967-016-5116-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gravimetry after calcination is an assay method for determining the quantity of a given element from the mass measurement. This method, adapted for high concentration and purity uranium solution, has the advantage of not being related to a chemical standard and of having an extremely high trueness and precision. Besides, the method is simple, robust and cost-effective. The results of the analytical method validation are shown. Expanded uncertainties, assessed thanks to a reference uranium nitrate solution, are lower than 0.2%. The technique can thus be used in addition to the well-known isotopic dilution thermal-ionisation mass-spectrometry.
引用
收藏
页码:1831 / 1838
页数:8
相关论文
共 50 条
  • [1] Validation of gravimetry for high-accuracy analysis of uranium
    Alexandre Ruas
    Warda Ben Messaoud
    Cédric Rivier
    Isabelle Solinhac
    Danièle Roudil
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 311 : 1831 - 1838
  • [2] Precision Analysis of a High-Accuracy Temperature Measurement Circuit Used in Airborne Gravimetry
    Li, Jilian
    Cao, Juliang
    Zhang, Kaidong
    Zhang, Qi
    ICMS2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION, VOL 6: MODELLING & SIMULATION INDUSTRIAL ENGINEERING & MANAGEMENT, 2010, : 312 - 315
  • [3] Design and analysis for a high-accuracy CCD
    Wang H.-S.
    Zhu W.-B.
    Wang Q.
    Chen C.-C.
    Optoelectronics Letters, 2011, 7 (3) : 167 - 170
  • [4] Design and analysis for a high-accuracy CCD
    Wang, He-shun
    Zhu, Wei-bing
    Wang, Qiang
    Chen, Ci-chang
    Optoelectronics Letters, 2011, 7 (03) : 167 - 170
  • [5] Design and analysis for a high-accuracy CCD
    王和顺
    朱维兵
    王强
    陈次昌
    Optoelectronics Letters, 2011, 7 (03) : 167 - 170
  • [6] Characterization of uncertainty contributions in a high-accuracy PMU validation system
    Frigo, G.
    Derviskadic, A.
    Colangelo, D.
    Braun, J. P.
    Paolone, M.
    MEASUREMENT, 2019, 146 : 72 - 86
  • [7] High-accuracy analysis of beams of bimodulus materials
    Iwase, T
    Hirashima, K
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2000, 126 (02): : 149 - 156
  • [8] Design and analysis of a high-accuracy flexure hinge
    Liu, Min
    Zhang, Xianmin
    Fatikow, Sergej
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [9] Wavefront analysis with high-accuracy inversion interferometer
    Spektor, B
    Shamir, J
    Bekker, AM
    OPTICAL ENGINEERING, 1997, 36 (06) : 1754 - 1759
  • [10] Error analysis in high-accuracy digital measurements
    Barros e Vasconcellos, Renata T.