Design of a lanthanum bromide detector for time-of-flight PET

被引:105
|
作者
Kuhn, A [1 ]
Surti, S
Karp, JS
Raby, PS
Shah, KS
Perkins, AE
Muehllehner, G
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
[2] Saint Gobain Crystals & Detectors, Newbury, OH 44065 USA
[3] Radiat Monitoring Dev, Watertown, MA 02472 USA
[4] Philips Med Syst, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
anger-logic; gamma-ray detectors; lanthanum detectors; positron emission tomography; scintillation detectors; 3-D PET; time resolution; time-of-flight;
D O I
10.1109/TNS.2004.835777
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent improvements in the growth and packaging of lanthanum bromide (LaBr3), in addition to its superb intrinsic properties of high light output, excellent energy resolution, and fast decay time, make it a viable detection material for a positron emission tomography (PET) scanner based on time-of-flight (TOF). We have utilized theoretical simulations and experimental measurements to investigate the design and performance of pixelated LaBr3 Anger-logic detectors suitable for use in a TOF PET scanner. Our results indicate that excellent energy resolution can be obtained from individual as well as multicrystal arrays of LaBr3 in a 4 mm x 4 mm x 30 mm geometry. Measured energy resolutions (at 511 keV) of 4.1% for a single crystal and an average of 5.1% for an array of 100 crystals have been achieved with our best samples. Both simulations and experimental measurements of an Anger-logic based detector consisting of the LaBr3 crystal array coupled to a continuous light guide and seven photomultiplier tubes (PMTs), have resulted in the ability to clearly discriminate 511 keV interactions in each crystal. We have measured coincidence time resolutions for both 0.5% and 5.0% cerium-doped LaBr3 and found that the higher level of Ce-doping yielded superior results with little to no degradation in light output or energy resolution. The time resolution for a single 5.0% Ce-doped LaBr3 crystal (4 mm x 4 mm x 30 mm) coupled directly to a PMT was measured to be 275 ps full-width at half-maximum (FWHM). With an array of 100 crystals coupled to a light guide and seven PMT cluster an average time resolution of 290 ps FWHM was obtained by summing the signals from the PMT cluster. Ultimately, two 5.0% Ce-doped LaBr3 Anger-logic detectors placed in coincidence yielded a time resolution of 313 ps FWHM.
引用
收藏
页码:2550 / 2557
页数:8
相关论文
共 50 条
  • [41] WARSAW TIME-OF-FLIGHT NEUTRON DETECTOR
    Wojtowicz, P.
    Miernik, K.
    Korgul, A.
    Piersa, M.
    Silkowski, M.
    Roginski, T.
    ACTA PHYSICA POLONICA B, 2020, 51 (03): : 725 - 730
  • [42] The time-of-flight detector of the ALICE experiment
    Scapparone, E.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2007, 34 (08) : S725 - S728
  • [43] A NEW TIME-OF-FLIGHT PARTICLE DETECTOR
    MUGA, ML
    BURNSED, DJ
    STEEGER, WE
    TAYLOR, HE
    NUCLEAR INSTRUMENTS & METHODS, 1970, 83 (01): : 135 - &
  • [44] TIMING PROPERTIES OF A TIME-OF-FLIGHT DETECTOR
    NAKAGAWA, T
    YUASANAKAGAWA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1989, 28 (03): : 498 - 500
  • [45] Evaluation of Fourier rebinning of time-of-flight PET data to non time-of-flight
    Li, Quanzheng
    Cho, S.
    Ahn, S.
    Ren, R.
    Leahy, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [46] Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector
    Chang, Chen-Ming
    Cates, Joshua W.
    Levin, Craig S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 258 - 271
  • [47] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198
  • [48] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [49] Clinical impact of time-of-flight PET
    Soussan, M.
    Galas, J-L
    Ouvrier, M-J
    Pop, G.
    Neuman, A.
    Weinmann, P.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (07): : 401 - 405
  • [50] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64