Quantitative Analysis of Bacoside A from Bacopa monnieri, Collected from Different Geographic Regions of India, by High-Performance Thin-Layer Chromatography-Densitometry

被引:7
|
作者
Ahmed, Aziz [1 ]
Ahmad, Sayeed [2 ]
Ur-Rahman, Mahfooz [1 ]
Tajuddin, Tamboli E. [2 ]
Verma, Ranbir [3 ]
Afzal, Mohd [4 ]
Mehra, Prahlad Singh [1 ]
机构
[1] Abhilashi Coll Pharm, Mandi 175033, HP, India
[2] Jamia Hamdard, New Delhi 110062, India
[3] Dreamz Coll Pharm, Tehsil Sundernagar 175036, HP, India
[4] Tabuk Pharmaceut, Dammam 4640, Saudi Arabia
关键词
Bacoside A; Robustness; Memory enhancer; High-performance thin-layer chromatography; Forced degradation; Precision; Accuracy; Recovery; GUINEA-PIG; EXTRACT; BRAHMI; RABBIT;
D O I
10.1556/1006.2015.28.4.4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Context: Bacoside A, a triterpenoid saponin, is a major constituent isolated from Bacopa monnieri (L.) Wettst. (Scrophulariaceae), used as a memory enhancer. Bacoside A and B are active ingredients in Bacopa herb and have antioxidant and hepatoprotective activities. Objective: A new rapid, simple, and economical high-performance thin-layer chromatographic (HPTLC) method was developed and validated for densitometric quantitative analysis of bacoside A in powdered leaves from different geographical regions of India. Materials and methods: An amount of 10 mg mL(-1) methanol extract of powdered leaves from different geographic regions was used for sample application on precoated silica gel 60 F-254 aluminum sheets. Standard bacoside A (1 mg mL(-1)) was used for calibration curve. HPTLC separation was performed on percolated silica gel aluminum plate 60 F-254 (20 cm x 10 cm with 0.2 mm thickness) as a stationary phase using ethyl acetate-methanol-water (4:1:1) as the mobile phase. Quantification was achieved by densitometric analysis at 598 nm over the concentration range of 500-4000 ng band(-1). Result: Compact and well-resolved bands for bacoside A from powdered leaves of different geographic regions were found at retardation factor (R-F) 0.53 +/- 0.02. The linear regression analysis data for calibration curve showed good linear relationship with regression coefficient r(2) = 0.9996 and r(2) = 0.99810 with respect to peak area and peak height. The method was validated for precision, recovery, and robustness as per the International Conference on Harmonization (ICH) guidelines. Variation in quantitative analysis of bacoside A in powdered leaves sample from different geographic regions was found by HPTLC method. Discussion and conclusion: The highest and lowest content of bacoside A in powdered leaves sample from Jammu and Kerala regions, respectively. The variety of B. monnieri in Jammu is superior to other regions of India. The proposed developed HPTLC method can be applied for the quantitative determination of bacoside A in powdered leaves of plant and its formulation.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [21] Determination of α-solanine and α-chaconine in potatoes by high-performance thin-layer chromatography/densitometry
    Bodart, Patricia
    Kabengera, Charles
    Noirfalise, Alfred
    Hubert, Philippe
    Angenot, Luc
    2000, AOAC International (83)
  • [22] Determination of lipids in animal tissues by high-performance thin-layer chromatography with densitometry
    Thanh, NTK
    Stevenson, G
    Obatomi, D
    Bach, P
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2000, 13 (05) : 375 - 381
  • [23] SALBUTAMOL IDENTIFICATION IN LIVER AND URINE BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY AND DENSITOMETRY
    DEGROOF, J
    DEGROODT, JM
    DEBUKANSKI, BW
    BEERNAERT, H
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1991, 193 (02): : 126 - 129
  • [24] Assay of naproxen in rat serum by high-performance thin-layer chromatography/densitometry
    Guermouche, MH
    Atik, N
    Chader, H
    JOURNAL OF AOAC INTERNATIONAL, 2000, 83 (06) : 1489 - 1492
  • [26] DETERMINATION OF GRAMICIDIN WITH QUANTITATIVE HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    KREUZIG, F
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1976, 282 (05): : 447 - 449
  • [27] COMPARISON BETWEEN HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY-DENSITOMETRY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF AJMALINE, RESERPINE AND RESCINNAMINE IN RAUWOLFIA-VOMITORIA ROOT BARK
    DUEZ, P
    CHAMART, S
    VANHAELEN, M
    VANHAELENFASTRE, R
    HANOCQ, M
    MOLLE, L
    JOURNAL OF CHROMATOGRAPHY, 1986, 356 (02): : 334 - 340
  • [28] Determination and Quantification of Amino Acids in the Urine of BALB/c Mice Infected with Echinostoma caproni by High-Performance Thin-Layer Chromatography-Densitometry
    Vasta, James D.
    Fried, Bernard
    Sherma, Joseph
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (09) : 1210 - 1222
  • [29] Ganglioside analysis by high-performance thin-layer chromatography
    Yu, RK
    Ariga, T
    SPHINGOLIPID METABOLISM AND CELL SIGNALING, PT B, 2000, 312 : 115 - 134
  • [30] Simultaneous quantification of vasicine and vasicinone in different parts of Justicia adhatoda using high-performance thin-layer chromatography-densitometry: comparison of different extraction techniques and solvent systems
    Padhiari, Bhuban Mohan
    Ray, Asit
    Jena, Sudipta
    Champati, Bibhuti Bhusan
    Sahoo, Ambika
    Mohanty, Swagat
    Nayak, Sanghamitra
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2020, 33 (06) : 599 - 607