Influence of the implant abutment types and the dynamic loading on initial screw loosening

被引:15
|
作者
Kim, Eun-Sook [1 ]
Shin, Soo-Yeon [1 ]
机构
[1] Dankook Univ, Coll Dent, Dept Prosthodont, Cheonan, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2013年 / 5卷 / 01期
关键词
Computer-aided design; Dental implantation; Prosthesis failure; Removal torque; Screw loosening; INTERNAL CONICAL INTERFACE; 3-YEAR FOLLOW-UP; DENTAL IMPLANTS; FRAMEWORKS; SYSTEMS; FIT; CONNECTION; STRENGTH; DESIGN;
D O I
10.4047/jap.2013.5.1.21
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 300 to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 10 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (alpha=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. [J Adv Prosthodont 2013;5:21-8]
引用
收藏
页码:21 / 28
页数:8
相关论文
共 50 条
  • [1] The influence of implant–abutment connection on the screw loosening and microleakage
    Katsuhiro Tsuruta
    Yasunori Ayukawa
    Tatsuya Matsuzaki
    Masafumi Kihara
    Kiyoshi Koyano
    International Journal of Implant Dentistry, 4
  • [2] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463
  • [3] Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage
    Katsuta, Yasuhiro
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 896 - 902
  • [4] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [5] Influence of the difference between implant body and screw materials on abutment screw loosening
    Shinohara, Ryusuke
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2019, 38 (01) : 150 - 156
  • [6] Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    Khraisat, A
    Hashimoto, A
    Nomura, S
    Miyakawa, O
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04): : 326 - 334
  • [7] Study of screw loosening in cementation type implant abutment
    Hwang, BY
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1267 - 1267
  • [8] A study on the abutment screw loosening phenomenon of dental implant
    Kang, YM
    Cho, IH
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1261 - 1261
  • [9] Implant Abutment Screw Loosening: A Review of Effective Factors
    Seddigh, Mohammad Ali
    Mostafavi, Azam Sadat
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (08) : ZE6 - ZE9
  • [10] Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading
    El-Sheikh, Mai Ahmed Yousry
    Mostafa, Tamer Mohamed Nasr
    El-Sheikh, Mohamed Maamoun
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4