Hemodynamic monitoring in obese patients: The impact of body mass index on cardiac output and stroke volume

被引:62
|
作者
Stelfox, HT
Ahmed, SB
Ribeiro, RA
Gettings, EM
Pomerantsev, E
Schmidt, U
机构
[1] Massachusetts Gen Hosp, Dept Anesthesia & Crit Care, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Dept Med, Brigham & Womens Hosp,Dept Anesthesia & Crit Care, Boston, MA 02115 USA
关键词
hemodynamic monitoring; body mass index; obesity; cardiac output; stroke volume;
D O I
10.1097/01.CCM.0000208358.27005.F4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Interpreting hemodynamic parameters in critically ill obese patents can be difficult as the effects of body mass index (BMI) on cardiac output (CO) and stroke volume (SV) at the extremes of body size remains unknown. We examined the relationship between BMI and both CO and SV for patients with varying body sizes. Design: Retrospective cohort analysis. Setting. A large tertiary care academic medical center. Patients: A total of 700 consecutive adults who were found to have disease-free coronary arteries and a cardiac output measurement (thermodilution or Fick method) during coronary angiography between July 1, 2000, and July 31, 2004. Measurements and Results: We examined the relationship between BMI (mean, 28 kg/m(2); range, 10.6-91.6 kg/m(2)) and cardiac hemodynamics after adjusting for demographic (age, sex) and clinical (diabetes, smoking status, valvular heart disease, medications, indications for catheterization) characteristics using multivariable regression. Body mass index was positively correlated with CO and SV. Each 1 kg/m(2) increase in BMI was associated with a 0.08 L/min (95% confidence interval [CI], 0.06-0.10; p < .001) increase in CO and 1.35 mL (95% Cl, 0.96-1.74; p < .001) increase in SV. There was no significant association between BMI and both cardiac index (0.003 L/min/M2; 95% Cl, -0.008-0.014; p = .571) and stroke volume index (0.17 mL/m(2); 95% CI, -0.03-0.37; p = .094). Conclusion: Variations in BMI translate into predictable but only modest differences in CO and SV, even at the extremes of body size. Indexing hemodynamic measurements to body surface area attenuates the effects of BMI. Body habitus should not appreciably complicate the interpretation of hemodynamic measurements.
引用
收藏
页码:1243 / 1246
页数:4
相关论文
共 50 条
  • [21] Impact of body mass index on the clinical outcomes in heart failure patients undergoing cardiac
    Kunimoto, M.
    Shimada, K.
    Yokoyama, M.
    Fujiwara, K.
    Honzawa, A.
    Yamada, M.
    Matsubara, T.
    Matsumori, R.
    Abulimiti, A.
    Asai, T.
    Amano, A.
    Morisawa, T.
    Takahashi, T.
    Daida, H.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3116 - 3116
  • [22] Body mass index is associated with low postoperative cardiac output in patients undergoing aortic valve replacement
    Avila-Vanzzini, Nydia
    Berrios-Barcenas, Enrique
    Cossio-Aranda, Jorge
    Herrera-Bello, Hector
    Rodriguez-Chavez, Laura L.
    Briseno-Diaz, Nidia M.
    Gaspar-Hernandez, Jorge
    ARCHIVOS DE CARDIOLOGIA DE MEXICO, 2020, 90 (04): : 453 - 460
  • [23] Centhaquine Increases Stroke Volume and Cardiac Output in Patients with Hypovolemic Shock
    Khanna, Aman
    Vaidya, Krish
    Shah, Dharmesh
    Ranjan, Amaresh K.
    Gulati, Anil
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [24] Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient
    Bernstein, Donald P.
    OBESITY SURGERY, 2008, 18 (08) : 1015 - 1021
  • [25] Pressure Pulse Contour-derived Stroke Volume and Cardiac Output in the Morbidly Obese Patient
    Donald P. Bernstein
    Obesity Surgery, 2008, 18 (8) : 1022 - 1022
  • [26] Pressure Pulse Contour-derived Stroke Volume and Cardiac Output in the Morbidly Obese Patient
    Donald P. Bernstein
    Obesity Surgery, 2008, 18 : 1015 - 1021
  • [27] RELIABILITY OF THE IMPEDANCE CARDIOGRAPHIC TECHNIQUE IN DETERMINING STROKE VOLUME, CONTRACTILITY, CARDIAC INDEX, AND CARDIAC-OUTPUT
    WEBB, JW
    GREENE, WA
    PSYCHOPHYSIOLOGY, 1984, 21 (05) : 603 - 603
  • [28] Cardiac Output Response to Exercise in Chronic Cardiac Failure Patients Role of Stroke Volume
    Fukuda, Taira
    Matsumuto, Akihiro
    Kurano, Miwa
    Takano, Haruhito
    Iida, Haruko
    Morita, Toshihiro
    Yamashita, Hiroshi
    Hirata, Yasunobu
    Nagai, Ryozo
    Nakajima, Toshiaki
    INTERNATIONAL HEART JOURNAL, 2012, 53 (05) : 293 - 298
  • [29] Evaluation of continuous monitoring of stroke volume and cardiac output in patients supported by an intra-aortic balloon pump
    Podbregar, M.
    Kosir, M.
    Stajer, D.
    Zdovc, J.
    Plaskan, S.
    MINERVA ANESTESIOLOGICA, 2013, 79 (07) : 762 - 770
  • [30] Does body mass index impact the outcome of stroke patients who received intravenous thrombolysis?
    Mowla, A.
    Zambrano, D.
    Lail, N. S.
    Crumlish, A.
    Ching, M.
    Deline, C.
    Vaughn, C. B.
    Sawyer, R. N.
    CEREBROVASCULAR DISEASES, 2017, 43