Calibration accuracy analysis of satellite channel zero-value based on TtC measurement

被引:0
|
作者
Zhu Feng [1 ,2 ]
Li Xiaohui [1 ,2 ]
Li Dandan [1 ,2 ,3 ]
Li Bo [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Natl Time Serv Ctr, Xian 710600, Shaanxi, Peoples R China
[2] Chinese Acad Sci, Key Lab Precise Nav & Timing Technol, Xian 710600, Shaanxi, Peoples R China
[3] Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R China
关键词
TtC; zero-value; calibration accuracy; pseudo-satellite; RMS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The calibration result of satellite channel zero-value through TtC measurement is directly related to the users' positioning and timing performance in navigation system. The paper proposes the concept of pseudo-satellite channel zero-value calibration that using a satellite signal simulator replaces the real satellite for testing, which mainly analyzes the calibration accuracy of TtC measurement. Using a delay-line instead of simulator adjustment to eliminate the system error the calibration accuracy decreases about 0.05ns on the original basis of 0.38ns. Through the testing comparison we can see the oscilloscope is better than the carrier phase receiver, with the calibration accuracy from 0.32ns up to 0.78ns.
引用
收藏
页码:552 / 555
页数:4
相关论文
共 50 条
  • [21] Tunable 4-Pole Noncontiguous 0.7-2.1-GHz Bandpass Filters Based on Dual Zero-Value Couplings
    Cho, Young-Ho
    Rebeiz, Gabriel M.
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (05) : 1579 - 1586
  • [22] A high accuracy digital phase measurement based on zero-discriminating
    Xu, DC
    Zhao, HM
    Zhou, XJ
    [J]. ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 253 - 256
  • [23] Measurement Accuracy Analysis of Multilateral Method Based on Optimal Layout with Non-directional Point Calibration
    Zou, Jingui
    Yang, Dingliang
    [J]. Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2022, 47 (10): : 1758 - 1765
  • [24] Upper and lower bounds on a system's bandwidth based on its zero-value time constants (vol 52, pg 1383, 2016)
    Hong, B.
    Hajimiri, A.
    [J]. ELECTRONICS LETTERS, 2016, 52 (16) : 1418 - 1418
  • [25] Simulation and Measurement-Based Vehicle-to-Vehicle Channel Characterization: Accuracy and Constraint Analysis
    Abbas, Taimoor
    Nuckelt, Joerg
    Kuerner, Thomas
    Zemen, Thomas
    Mecklenbraeuker, Christoph F.
    Tufvesson, Fredrik
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2015, 63 (07) : 3208 - 3218
  • [26] Analysis of Measurement Accuracy of Devices Used for Calibration of Blood Pressure and Pulse Monitors
    Soiko A.I.
    [J]. Biomedical Engineering, 2011, 45 (3) : 98 - 103
  • [27] Accuracy analysis of satellite measurements of the measurement geodetic control network on the southern Spitsbergen
    Glowacki, Tadeusz
    [J]. XVIII CONFERENCE OF PHD STUDENTS AND YOUNG SCIENTISTS INTERDISCIPLINARY TOPICS IN MINING AND GEOLOGY, 2018, 71
  • [28] Analysis of the overall accuracy in LDV measurement of film flow in an inclined channel
    Aksel, N
    Schmidtchen, M
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (08) : 1140 - 1147
  • [29] Accuracy Analysis of Radiometric Calibration In-Orbit for SuperView Neo-2 SAR Satellite
    Li, Huijuan
    Zhang, Heng
    Chen, Qi
    Gao, Yongpeng
    Shi, Xiaoyu
    Zhang, Lifeng
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 2234 - 2244
  • [30] Analysis of focusing accuracy for multispectral CCD camera based on satellite
    Lv, Shiliang
    Liu, Jinguo