On the Laplacian operation with applications in magnetic resonance electrical impedance imaging

被引:7
|
作者
Xu, Huilin [1 ,2 ]
Liu, Jijun [1 ]
机构
[1] Southeast Univ, Dept Math, Nanjing 210096, Jiangsu, Peoples R China
[2] Henan Polytech Univ, Sch Math & Informat Sci, Jiaozuo 454000, Peoples R China
关键词
Laplacian operation; ill-posedness; regularization; MREIT; convergence; numerical solution; NUMERICAL DIFFERENTIATION; LAVRENTIEV REGULARIZATION; INVERSE PROBLEM; MODEL; CONVERGENCE; PARAMETERS; PRINCIPLE; EQUATIONS; CHOICE;
D O I
10.1080/17415977.2012.687734
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Consider the numerical computation of Laplacian operation from the noisy data of a given function f(x) defined in < subset of>2. By expressing this ill-posed problem as a Fredholm integral equation of the first kind, we construct the approximate solution from a PDE boundary value problem directly, which can be considered as the Lavrentiev regularization in essence. The optimal error estimate of this regularization for an appropriate a posteriori choice strategy of the regularization parameter is given under some source conditions of the exact Laplacian operation. An iterative algorithm for computing this a posteriori regularization parameter under the framework of model function method is also given with its convergence analysis. The advantage of the proposed scheme is that we treat the Laplacian operation as a whole, rather than the partial derivatives of each variable, and therefore the Laplacian operation can be computed in a bounded domain with arbitrary boundary shape for noisy data specified at randomly scattered points. At last, we apply this scheme to the iterative algorithm of reconstructing the conductivity in magnetic resonance electrical impedance tomography, where the input data is the magnetic flux data for which the Laplacian operation must be carried out. The validity of the proposed scheme is shown numerically for this new medical imaging technology.
引用
收藏
页码:251 / 268
页数:18
相关论文
共 50 条
  • [1] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [2] Coregistration of electrical impedance tomography and magnetic resonance imaging
    Halter, R. J.
    Manwaring, P.
    Hartov, A.
    Paulsen, K. D.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 416 - 419
  • [3] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [4] Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
    Degirmenci, E.
    Eyuboglu, B. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 728 - 731
  • [5] Impedance magnetic resonance imaging: a method for imaging of impedance distributions based on magnetic resonance imaging
    Ueno, S.
    Iriguchi, N.
    Journal of Applied Physics, 1998, 83 (11 pt 2):
  • [6] Impedance magnetic resonance imaging: A method for imaging of impedance distributions based on magnetic resonance imaging
    Ueno, S
    Iriguchi, N
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6450 - 6452
  • [7] Noninvasive imaging of head-brain conductivity profiles - Applications of magnetic resonance electrical impedance tomography
    Zhang, Xiaotong
    Yan, Dandan
    Zhu, Shanan
    He, Bin
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (05): : 78 - 83
  • [8] Magnetic resonance-electrical impedance tomography in breast cancer imaging
    Birgul, Ozlem
    Hamamura, Mark J.
    Muftuler, L. Turgan
    Nalcioglu, Orhan
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 686 - +
  • [9] Electrical conductivity imaging of postmortem canine brains using magnetic resonance electrical impedance tomography
    Woo, Eung Je
    Kim, Hyung Joong
    Lee, Byung Il
    Kim, Young Tae
    Lee, Soo Yeol
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4146 - 4149
  • [10] Electrical Conductivity Imaging Using A Hybrid Regularization Method in Magnetic Resonance Electrical Impedance Tomography
    Wang, Zewen
    Qiu, Shufang
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 205 - +