Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device

被引:94
|
作者
Gerckens, U [1 ]
Cattelaens, N [1 ]
Lampe, EG [1 ]
Grube, E [1 ]
机构
[1] Herzentrum Siegburg, Siegburg, Germany
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1999年 / 83卷 / 12期
关键词
D O I
10.1016/S0002-9149(99)00174-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To overcome the challenge associated with achievement in hemostasis after a catheterization procedure, a suture-based closure device was compared with manual compression in a 600-patient randomized trial. The major study end points included the incidence of vascular complications and the time to ambulation after the procedure. The study included diagnostic or interventional procedures. The suture-mediated closure was performed immediately after the procedure independent of the anticoagulation level, whereas manual compression was performed per hospital protocol with sheath removal relying on normalization of patient's anticoagulation status. A significant reduction in time to achieve hemostasis (7.8 +/- 4.8 vs 19.6 +/- 13.2 minutes, p < 0001) and time to ambulation (4.5 +/- 6.5 vs 17.8 +/- 5 hours, p < 0001) was associated with use of the suture-mediated closure device. The incidence of vascular complications was similar in the overall population (5.7% for suturing device vs 11.3% for compression) or in the interventional patient subset (8.4% for suturing device vs 9.6% for compression). There was a significant reduction in the incidence of vascular complications in the diagnostic procedure subset (4.4% for suturing device vs 12.1% for compression, p < 0.05). Thus, the use of a suture-mediated closure device represents a safe alternative to manual compression. Hemostasis and ambulation can be achieved faster with the suturing device than with manual compression, with a potential reduction in access site complications. (C) 1999 by Excerpta Medico, Inc.
引用
收藏
页码:1658 / 1663
页数:6
相关论文
共 50 条
  • [21] Ultrasonographic assessment and clinical outcomes after deployment of a suture-mediated femoral vascular closure device
    Papoutsis, Dimitrios
    Mourouzis, Konstantinos
    Bozini, Nikoleta
    Aznaouridis, Konstantinos
    Oikonomou, Evangelos
    Chatzimichael, Katerina
    Brountzos, Elias
    Vavuranakis, Manolis
    Tsioufis, Costas
    Lekakis, John
    Siasos, Gerasimos
    Tousoulis, Dimitris
    CARDIOVASCULAR JOURNAL OF AFRICA, 2023,
  • [22] Percutaneous Closure of Gastrostomy Using a Suture-Mediated Vascular Closure Device in a Swine Model
    Euichul Jung
    Sung Bum Cho
    Hyoung Rae Kim
    Yun Hwan Kim
    Hwan Hoon Chung
    Seung Hwa Lee
    Deuk Jae Sung
    CardioVascular and Interventional Radiology, 2020, 43 : 781 - 786
  • [23] Percutaneous Closure of Gastrostomy Using a Suture-Mediated Vascular Closure Device in a Swine Model
    Jung, Euichul
    Cho, Sung Bum
    Kim, Hyoung Rae
    Kim, Yun Hwan
    Chung, Hwan Hoon
    Lee, Seung Hwa
    Sung, Deuk Jae
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) : 781 - 786
  • [24] Nonocclusive "Island" of Stenosis after Suture-mediated Arteriotomy Closure
    Wickman, Christopher
    Resnick, Scott A.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (12) : 1642 - 1644
  • [25] Ultrasonography-guided endovascular management of femoral artery pseudoaneurysm after unintended dialysis catheterization with suture-mediated vascular closure devices
    Cho, Hyung-Jin
    Jeon, Chang Ho
    Kim, Mi-Hyeong
    Lee, Jeong-Min
    Hwang, Jeong-Kye
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (06): : 2031 - 2035
  • [26] Suture-Mediated Arterial Closure Devices Decrease ACC/NCDR Major Bleeding as Compared with a Collagen Based Device
    Saffey, David M.
    Allen, Drew
    Lindsey, Jason
    Kennedy, Kevin
    Allen, Keith
    Marso, Steven
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 82D - 83D
  • [27] Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair
    Chan, Gabriel
    Quek, Lawrence Hwee Han
    Tan, Glenn Leong Wei
    Pua, Uei
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (07) : 1036 - 1039
  • [28] Atrial function analysis after percutaneous umbrella device and suture-mediated patent fossa ovalis closure
    Tarsia, Carmela
    Gaspardone, Carlo
    Sgueglia, Gregory A.
    De Santis, Antonella
    D'ascoli, Emanuela
    Piccioni, Fabiana
    Iamele, Maria
    Posteraro, Giuseppe A.
    Cinque, Alessandra
    Gaspardone, Achille
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2023, 71 (01) : 83 - 90
  • [29] Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair
    Gabriel Chan
    Lawrence Hwee Han Quek
    Glenn Leong Wei Tan
    Uei Pua
    CardioVascular and Interventional Radiology, 2016, 39 : 1036 - 1039
  • [30] Safety and efficacy of suture-mediated closure after percutaneous coronary interventions
    Rinder, MR
    Tamirisa, PK
    Taniuchi, M
    Kurz, HI
    Mumm, K
    Lasala, JM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (02) : 146 - 151